Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual

Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual

Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 271

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-9 Add the Fiber Optic Cable 
6
LASER Product
CLASS 1 LASER PRODUCT
IEC 825 1993
The DEFINITY ECS may c ontain a Class 1 LASER devic e if sing le-mod e fib er 
op tic  c ab le is c onnec ted  to a remote Exp ansion Port Network (EPN). The LASER 
d evic e op erates within the following  p arameters:
nMaximum Power Outp ut: -5d Bm
nWaveleng th: 1310 nm...

Page 272

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-10 Add the Fiber Optic Cable 
6
Cabinet Preparation
1. Open the front d oor.
NOTE:
Ad ministration may b e req uired  b efore removing  the c irc uit p ac k in 
the following  step .
2. Determine which slot (1 or 2) will c ontain the new fiber optic circuit pac k. 
Remove the c irc uit p ac k or the b lanking  p late from this slot. 
NOTE:
If a c irc...

Page 273

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-11 Add the Fiber Optic Cable 
6
Figure 6-2. Remove the I/O Cable Connector
7. Using  a sup p lied  c able tie, sec ure the removed  I/O c onnec tor to nearb y 
c ab ling. See Figure 6-3
. Figure Notes
1. Press tab  down 2. Pull c onnec tor forward
lcda8fop RPY 021198
1
2 

Page 274

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-12 Add the Fiber Optic Cable 
6
Figure 6-3. Secure the I/O Cable Connector
8. From the front, remove the fan c over. See Figure 6-4
. Figure Notes
1. Tie wrap
lcda9fop RPY 0213981 

Page 275

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-13 Add the Fiber Optic Cable 
6
Figure 6-4. Remove the Fan Cover
lcda3fop EWS 110398
ENTER
/YES ENTER
/YES NEXT
/NO NEXT
/
NO BACK
BACK
AUDIX AUDIXBOOT/
SHUTDOWN BOOT/
SHUTDOWN
ALARMS
ALARMS
EMERTR
EMERTR 

Page 276

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-14 Add the Fiber Optic Cable 
6
Install the Pass-thru Kit
1. Snap  the SC-SC fib er op tic  adap ter on the p ass-thru tool. See Figure 6-5. 
Use the b eig e ad apter even if sing le-mod e fib er is b eing  installed . The 
SC-SC ad ap ter is b etter suited  for c ab le routing  in the next step s. 
NOTE:
If sing le-mod e fib er is being installed ,...

Page 277

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-15 Add the Fiber Optic Cable 
6
Figure 6-6. Insert the Pass-thru Tool
!CAUTION:
Avoid  b end ing  fib er op tic  c ab les to a rad ius smaller than 1.5 inc hes 
(3.8 c m), to p revent mec hanic al stress on the c ab les. 
!CAUTION:
During  the ac tual installation of fiber op tic  c omp onents, use either all b eig e 
or all b lue ad ap ters. Beig e...

Page 278

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-16 Add the Fiber Optic Cable 
6
4. Pull the tool (with ad apter and  c ab le attac hed ) out throug h the front of the 
c ab inet. See Figure 6-7
.
Figure 6-7. Fiber Optic Cable and Adapter
5. From the rear, route the fib er op tic  c ab le throug h the op ening  vac ated  b y 
the I/O c able c onnec tor.
6. If nec essary, remove the fiber ad ap ter...

Page 279

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-17 Add the Fiber Optic Cable 
6
Figure 6-8. Bracket Attachments 
10. Wrap  the c ab le d isc onnec t lab el around  the fib er op tic  c ab le. See 
Figure 6-9
. Figure Notes:
1. Fiber cable
2. I/O c onnec tor ad ap ter b rac ket3. SC-SC adapter
4. SC-ST ad ap ter
lcda7fop KLC 051198
1
2
3
4
2 

Page 280

DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  555-233-115  Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-18 Add the Fiber Optic Cable 
6
Figure 6-9. Cable Disconnect Label
11. Close the rear door.
!CAUTION:
Avoid  b end ing  fib er op tic  c ab les to a rad ius smaller than 1.5 inc hes 
(3.8 c m), to p revent mec hanic al stress on the c ab les. Plan the use of 
c ab le ties to avoid c rimping  the c ab le or c reating  a fixed stress point 
where, at a...
Start reading Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual

Related Manuals for Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 Upgrades And Additions Manual

All Lucent Technologies manuals