Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 System Description Manual

Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 System Description Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 System Description Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Technical Specifications 
    211 Additional Hardware to Use Features 
    Extended user 
    administration of 
    redirected calls
    (Category A only)No additional hardware required.
    External device 
    alarmingNo additional hardware required.
    Facility busy indi-
    cationNo additional hardware required other than a feature button with a 
    light.
    Facility test calls No additional hardware required.
    Fiber link admin-
    istrationFor a public network, a CSU. For a campus network, a digital data 
    module or similar device.
    Go to cover No additional hardware required.
    Hold No additional hardware required.
    Hold - automatic No additional hardware required.
    Hot line service No additional hardware required.
    Hunt group No additional hardware required.
    Facility and 
    non-facility asso-
    ciated signalingSee ISDN-BRI.
    Flexible billing An ASAI adjunct processor is required.
    Generalized 
    MFCDS1 interface 24/32 and call classifier circuit packs.  DEFINITY sup-
    ports MFC in roughly 40 countries.  In all of those countries, you 
    need some type of trunk interface circuit pack and a call classifier 
    circuit pack.  some countries require a digital interface and some 
    require an analog interface and some can use either one.
    German — digital DS1 interface 24/32 for German digital trunks (such as PRI).
    Greece MFC DS1 interface 24/32 and call classifier circuit packs.
    Table 49.Additional Hardware to Use Features  — Continued  
    Feature Hardware
    Continued on next page 
    						
    							Technical Specifications 
    212 Additional Hardware to Use Features 
    DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Inbound call 
    management 
    (ICM) (Category 
    A only)ASAI hardware (See ASAI feature). Use of ACD feature required 
    (see ACD feature).
    Individual atten-
    dant accessNo additional hardware required.
    Integrated 
    announcementSee Recorded Announcement.
    Integrated direc-
    toryIf the terminal is connected to an associated data terminal, the 
    7404D voice terminal requires an optional Messaging Cartridge.
    Intercept treat-
    mentRequires announcement equipment and 1 port on an analog line cir-
    cuit pack for each announcement and for each external analog 
    announcement device, or an AUX trunk port for each external AUX 
    trunk device. See Recorded Announcements. A TN750C Announce-
    ment circuit pack can provide up to 256 announcements. Intercept 
    treatment can be administered to the attendant console.
    Intercom - auto-
    maticNo additional hardware required.
    Intercom — dial No additional hardware is required.
    Internal auto-
    matic answer 
    (IAA)All multi-function voice terminals with speakerphone or headset may 
    be used (except ISDN-BRI voice terminals) plus a port interface on a 
    circuit pack.
    Inter-PBX atten-
    dant callsTie trunk group between the branch and main locations.
    IP trunk All: TN802 MAPD IP Trunk circuit pack, TN802 External Cable 
    Assembly, three adjacent, vacant slots in the carrier. 
    Ta b l e  4 9 .Additional Hardware to Use Features  — Continued  
    Feature Hardware
    Continued on next page 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Technical Specifications 
    213 Additional Hardware to Use Features 
    ISDN-BRI line All: BRI line circuit pack
    R8si: a packet interface circuit pack for PRI over the packet inter-
    face, TN794 Netpacket circuit pack.
    R8si: TN570 expansion interface circuit pack (for system connectiv-
    ity in multiple port network systems), maintenance/test circuit pack in 
    the PPN (for packet applications), maintenance/test circuit pack in 
    each additional EPN (for critical reliability systems).
    R8r: Maintenance/test circuit pack in the PPN (for packet applica-
    tions), maintenance/test circuit pack in each additional EPN (for criti-
    cal reliability systems).
    ISDN-BRI trunk One BRI trunk circuit pack for up to eight 2B+D interfaces. 
    ISDN-PRI One PRI DS1 (T1/E1) interface circuit pack provides a signaling link 
    and up to 23 ISDN-PRI trunk group members and up to 30 for E1 
    channels. R8si: a processor interface circuit pack for PRI over PI, a 
    packet control circuit pack for PRI via the LAN bus and NetPacket. 
    R8csi/r: no additional hardware beyond DS1 interface. 
    Last number 
    dialedNo additional hardware required.
    Leave word call-
    ingDisplay terminal to store and retrieve the LWC message.
    Line lockout No additional hardware required.
    Listed directory 
    numbersNo additional hardware required.
    Look ahead inter-
    flow (Category A 
    only)No additional hardware is required. Interconnecting facilities must be 
    ISDN-PRI with no interworking. Calls that interwork may interflow 
    successfully but the ability to do so on an intelligent basis is lost, as 
    is the look ahead interflow DNIS information.
    Table 49.Additional Hardware to Use Features  — Continued  
    Feature Hardware
    Continued on next page 
    						
    							Technical Specifications 
    214 Additional Hardware to Use Features 
    DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Loudspeaker 
    paging accessRequires loudspeaker paging equipment and 1 port on an auxiliary 
    trunk circuit pack for each individual paging zone port (9 maximum). 
    Paging interface equipment consisting of a 909-type voice coupler 
    adapter (only if equipment is not FCC-registered) and a 24-volt 
    power supply, per zone. This hardware can be shared with the code 
    calling access feature. If PagePac paging system equipment is 
    used, 1 port on a CO trunk, analog line, or auxiliary trunk circuit pack 
    is used, depending on the PagePac arrangement.
    Loudspeaker 
    paging access - 
    deluxeLoudspeaker paging equipment and 1 port on an auxiliary trunk cir-
    cuit pack per zone. Paging interface equipment consisting of a 
    909-type voice coupler adapter (only if equipment is not FCC- regis-
    tered) and a 24-volt power supply, per zone. This hardware can be 
    shared with the code calling access feature. 
    Malicious call 
    traceA display set and optional CPE recording device.
    Manual mes-
    sage waitingNo additional hardware required.
    Manual originat-
    ing line serviceNo additional hardware required.
    Manual signaling No additional hardware required.
    MERLIN/system 
    25 - voice termi-
    nal support 
    (731xH Series)No additional hardware required.
    Messaging 
    server interfaceR8si requires a processor interface circuit pack. A port on a digital 
    line circuit pack is required to provide the MS interface This applica-
    tion also requires an ADU and a port on a data line circuit pack or a 
    modem and an analog line circuit pack. R8r: The BX.25 connection 
    requires a PGATE circuit pack.
    MFC enhance-
    mentsDS1 interface 24/32 and call classifier circuit packs.
    Ta b l e  4 9 .Additional Hardware to Use Features  — Continued  
    Feature Hardware
    Continued on next page 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Technical Specifications 
    215 Additional Hardware to Use Features 
    MF shuttle  DS1 interface 24/32 and call classifier circuit packs.
    MF signaling No additional hardware required.
    Misoperations 
    handlingNo additional hardware required.
    Modem pooling 
    (Category A only)One pooled modem circuit pack per 2 integrated conversion 
    resources provided. Each combined conversion resource requires 1 
    port on the digital line circuit pack, 1 port on an analog line circuit 
    pack, and an analog modem and data module or 7400 terminal.
    Multi-appear-
    ance preselec-
    tion and 
    preferenceMultiappearance telephone.
    Multimedia appli-
    cations server 
    interface (MASI)
    (Category A only)DS1 interface 24/32 and call classifier circuit packs.
    Multimedia call 
    appearances
    (Category A only)Requires no additional hardware.
    Multimedia call 
    early answer on 
    vectors and sta-
    tions (Category A 
    only)Requires no additional hardware.
    Multimedia call 
    handling 
    (MMCH) (Cate-
    gory A only)Multimedia interface circuit pack and multimedia voice conditioner 
    circuit pack to provide multimedia call processing. A digital line port 
    and BRI data port per multimedia complex.
    Table 49.Additional Hardware to Use Features  — Continued  
    Feature Hardware
    Continued on next page 
    						
    							Technical Specifications 
    216 Additional Hardware to Use Features 
    DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Multiple call han-
    dling on request 
    or forced (forced 
    is Category A 
    only)A multi-appearance set is required.
    Multimedia call 
    redirection to MM 
    endpoint (Cate-
    gory A only)Requires no additional hardware.
    Multimedia data 
    conferencing via 
    expansion ser-
    vices module 
    (ESM) (Category 
    A only)ESM adjunct device (terminates T.120 protocol and provides data 
    conference control and data distribution), TN2207 modified PRI cir-
    cuit pack, TN787 multimedia interface circuit pack, a cable to con-
    nect the TN2207 to the TN787
    Multimedia hold, 
    conference, 
    transfer, and 
    drop (Category A 
    only)Requires no additional hardware.
    Multimedia 
    multiple-port net-
    work (Category A 
    only)Requires no additional hardware.
    Multimedia queu-
    ing with voice 
    announcement 
    (Category A only)Requires no additional hardware.
    Ta b l e  4 9 .Additional Hardware to Use Features  — Continued  
    Feature Hardware
    Continued on next page 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Technical Specifications 
    217 Additional Hardware to Use Features 
    Multimedia ser-
    vice-link architec-
    ture support of 
    voice/data mode 
    (Category A only)Requires no additional hardware.
    Music-on-hold 
    accessMusic source and 1 port on an auxiliary trunk or analog line circuit 
    pack are required. A 909-type voice coupler is required if the system 
    is not FCC-registered (United States only). A music source and 1 
    port on a TN746B or TN468B or later Analog Line circuit pack. A 
    KS23395, L4 Music-on-Hold interface to convert a loop start port into 
    a Music-on-Hold port. The port must be administered for this pur-
    pose. Also, a 909-type voice coupler is required if the music source 
    is not FCC-registered (United States only). France: a port on the 
    TN2183 Analog Line circuit pack and the 122A Music-on-Hold inter-
    face unit (wall-mounted).
    Names registra-
    tion A PMS can connect through a data module and a port on a digital 
    line circuit pack, or through an ADU and a port on a data line circuit 
    pack. A journal printer requires a data module and a port on a digital 
    line circuit pack, or an ADU and a port on a data line circuit pack.
    National ISDN-1 DS1 Interface circuit pack.
    Native support of 
    6402D display 
    terminalRequires no additional hardware.
    Network access 
    — publicOne port on a CO or DIOD trunk circuit pack or 1 port on a DS1/E1 
    interface circuit pack or tie trunk circuit pack.
    Night Service - 
    hunt group, night 
    console service 
    and night station 
    serviceNo additional hardware required other than a button to activate and 
    deactivate the feature.
    Table 49.Additional Hardware to Use Features  — Continued  
    Feature Hardware
    Continued on next page 
    						
    							Technical Specifications 
    218 Additional Hardware to Use Features 
    DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Night service — 
    trunk answer 
    from any stationRinging device and 1 port on an analog line circuit pack.
    Night service - 
    trunk groupNo additional hardware required other than a button to activate and 
    deactivate the feature.
    NT interface on 
    TN556B/CRequires no additional hardware.
    NT QSIG peer 
    protocolRequires no additional hardware.
    Off-premises 
    data extensionsTrunk data module or DCP extender and 1 port on a digital line cir-
    cuit pack or DS1 circuit pack.
    Off-premises sta-
    tionCross-connecting capabilities and 1 port on an analog line circuit 
    pack or DS1 circuit pack.
    Outbound call 
    management 
    (OCM) (Cate-
    gory A only)Requires a TN2182B tone-clock circuit pack. Can also use an older 
    tone-clock as long as a TN744C or newer tone detector circuit pack 
    is in the system.
    PC application 
    software transla-
    tion exchange 
    (PASTE) (Cate-
    gory A only)A port on a digital line or BRI line circuit pack connected through a 
    Personal Computer configured with the PC/PBX, PC/ISDN, or Pas-
    sageWay circuit pack and application software to an appropriate 
    voice terminal.
    PC interface 
    (hardware varies 
    depending on the 
    configuration 
    group used)Group 2: 7400-series DCP terminals, PC/PBX interface card, an 
    IBM-compatible PC (6300 or 6300 Plus with DOS 3.1 or later, or 
    PC/XT with PC-DOS 3.1 or later. 448K or more of RAM is recom-
    mended on PCs running integrated software applications.
    Group 3: 7500-series ISDN-BRI Voice Terminal, up to 4 PC/ISDN 
    expansion cards, an IBM-compatible PC (6300, 6300 Plus, PC/XT, 
    PC/AT, PS/2, or Compaq), and DOS 3.1 or later.
    Ta b l e  4 9 .Additional Hardware to Use Features  — Continued  
    Feature Hardware
    Continued on next page 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Technical Specifications 
    219 Additional Hardware to Use Features 
    PC/PBX connec-
    tion A port on a digital line circuit pack for each PC/PBX connected. 
    Personal central 
    office line 
    (PCOL)A port on a central office trunk circuit pack for each trunk assigned 
    as a PCOL.
    Personal station 
    accessDigital line ports and a digital voice terminal.
    Personalized 
    ringingNo additional hardware required.
    Power Failure 
    TransferOne emergency transfer panel per 5 or 6 trunks assigned to Power 
    Failure Transfer, depending on panel used. The following panels are 
    available:
    n808A Panel — Serves up to 5 failure transfer terminals. The unit 
    provides automatic ground start or loop start
    nZ1A Panel — Serves up to 6 power failure transfer terminals. A 
    ground-start key is required at each preselected voice terminal 
    when ground-start trunks are used
    PRI Converter DASS - 1 TN464F DS1/E1 circuit pack and 1 TNCCSC-1 circuit 
    pack.
    DPNSS - 1 TN464F DS1/E1 circuit pack and 1 TNCCSC-2 circuit 
    pack.
    BRI - 1 TN464F DS1/E1 circuit pack and 1 TNPRI/BRI circuit pack.
    Priority Calling No additional hardware required.
    Privacy - Atten-
    dant LockoutNo additional hardware required.
    Privacy - Manual 
    ExclusionNo additional hardware required.
    Table 49.Additional Hardware to Use Features  — Continued  
    Feature Hardware
    Continued on next page 
    						
    							Technical Specifications 
    220 Additional Hardware to Use Features 
    DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Property Man-
    agement System 
    (PMS)For all except R8r, either:
    1. Using a digital line port and a data module, or
    2. Using a digital line port and an ADU
    For R8r, either:
    1. A packet data circuit pack cross-connected to a port on a data 
    line circuit pack, connected to a second data line circuit pack 
    port and then to an ADU, or 
    2. A packet data circuit pack cross-connected to a port on a data 
    line circuit pack connected to either a BRI line circuit pack 
    connected to a 7500 Data Module or to a digital line connected 
    to a data module. Data line circuit pack with an ADU or a data 
    module and port on a digital line circuit pack.
    Public Network 
    Call PriorityNo additional hardware required.
    Pull Transfer No additional hardware is required in a stand-alone configuration. In 
    a network environment, the TGU/TGE tie trunks (TN497) are the 
    only trunks that support the flash signaling necessary to complete 
    the pull transfer operation between systems.
    QSIG Global 
    NetworkingSame as ISDN-PRI. See ISDN-PRI.
    QSIG call offer 
    (Category A only)
    QSIG call com-
    pletion (Cate-
    gory A only)No additional hardware is required.
    Ta b l e  4 9 .Additional Hardware to Use Features  — Continued  
    Feature Hardware
    Continued on next page 
    						
    All Lucent Technologies manuals Comments (0)

    Related Manuals for Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 System Description Manual