Home
>
Lucent Technologies
>
Communications System
>
Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 System Description Manual
Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 System Description Manual
Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 System Description Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 Technical Specifications 211 Additional Hardware to Use Features Extended user administration of redirected calls (Category A only)No additional hardware required. External device alarmingNo additional hardware required. Facility busy indi- cationNo additional hardware required other than a feature button with a light. Facility test calls No additional hardware required. Fiber link admin- istrationFor a public network, a CSU. For a campus network, a digital data module or similar device. Go to cover No additional hardware required. Hold No additional hardware required. Hold - automatic No additional hardware required. Hot line service No additional hardware required. Hunt group No additional hardware required. Facility and non-facility asso- ciated signalingSee ISDN-BRI. Flexible billing An ASAI adjunct processor is required. Generalized MFCDS1 interface 24/32 and call classifier circuit packs. DEFINITY sup- ports MFC in roughly 40 countries. In all of those countries, you need some type of trunk interface circuit pack and a call classifier circuit pack. some countries require a digital interface and some require an analog interface and some can use either one. German — digital DS1 interface 24/32 for German digital trunks (such as PRI). Greece MFC DS1 interface 24/32 and call classifier circuit packs. Table 49.Additional Hardware to Use Features — Continued Feature Hardware Continued on next page
Technical Specifications 212 Additional Hardware to Use Features DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 Inbound call management (ICM) (Category A only)ASAI hardware (See ASAI feature). Use of ACD feature required (see ACD feature). Individual atten- dant accessNo additional hardware required. Integrated announcementSee Recorded Announcement. Integrated direc- toryIf the terminal is connected to an associated data terminal, the 7404D voice terminal requires an optional Messaging Cartridge. Intercept treat- mentRequires announcement equipment and 1 port on an analog line cir- cuit pack for each announcement and for each external analog announcement device, or an AUX trunk port for each external AUX trunk device. See Recorded Announcements. A TN750C Announce- ment circuit pack can provide up to 256 announcements. Intercept treatment can be administered to the attendant console. Intercom - auto- maticNo additional hardware required. Intercom — dial No additional hardware is required. Internal auto- matic answer (IAA)All multi-function voice terminals with speakerphone or headset may be used (except ISDN-BRI voice terminals) plus a port interface on a circuit pack. Inter-PBX atten- dant callsTie trunk group between the branch and main locations. IP trunk All: TN802 MAPD IP Trunk circuit pack, TN802 External Cable Assembly, three adjacent, vacant slots in the carrier. Ta b l e 4 9 .Additional Hardware to Use Features — Continued Feature Hardware Continued on next page
DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 Technical Specifications 213 Additional Hardware to Use Features ISDN-BRI line All: BRI line circuit pack R8si: a packet interface circuit pack for PRI over the packet inter- face, TN794 Netpacket circuit pack. R8si: TN570 expansion interface circuit pack (for system connectiv- ity in multiple port network systems), maintenance/test circuit pack in the PPN (for packet applications), maintenance/test circuit pack in each additional EPN (for critical reliability systems). R8r: Maintenance/test circuit pack in the PPN (for packet applica- tions), maintenance/test circuit pack in each additional EPN (for criti- cal reliability systems). ISDN-BRI trunk One BRI trunk circuit pack for up to eight 2B+D interfaces. ISDN-PRI One PRI DS1 (T1/E1) interface circuit pack provides a signaling link and up to 23 ISDN-PRI trunk group members and up to 30 for E1 channels. R8si: a processor interface circuit pack for PRI over PI, a packet control circuit pack for PRI via the LAN bus and NetPacket. R8csi/r: no additional hardware beyond DS1 interface. Last number dialedNo additional hardware required. Leave word call- ingDisplay terminal to store and retrieve the LWC message. Line lockout No additional hardware required. Listed directory numbersNo additional hardware required. Look ahead inter- flow (Category A only)No additional hardware is required. Interconnecting facilities must be ISDN-PRI with no interworking. Calls that interwork may interflow successfully but the ability to do so on an intelligent basis is lost, as is the look ahead interflow DNIS information. Table 49.Additional Hardware to Use Features — Continued Feature Hardware Continued on next page
Technical Specifications 214 Additional Hardware to Use Features DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 Loudspeaker paging accessRequires loudspeaker paging equipment and 1 port on an auxiliary trunk circuit pack for each individual paging zone port (9 maximum). Paging interface equipment consisting of a 909-type voice coupler adapter (only if equipment is not FCC-registered) and a 24-volt power supply, per zone. This hardware can be shared with the code calling access feature. If PagePac paging system equipment is used, 1 port on a CO trunk, analog line, or auxiliary trunk circuit pack is used, depending on the PagePac arrangement. Loudspeaker paging access - deluxeLoudspeaker paging equipment and 1 port on an auxiliary trunk cir- cuit pack per zone. Paging interface equipment consisting of a 909-type voice coupler adapter (only if equipment is not FCC- regis- tered) and a 24-volt power supply, per zone. This hardware can be shared with the code calling access feature. Malicious call traceA display set and optional CPE recording device. Manual mes- sage waitingNo additional hardware required. Manual originat- ing line serviceNo additional hardware required. Manual signaling No additional hardware required. MERLIN/system 25 - voice termi- nal support (731xH Series)No additional hardware required. Messaging server interfaceR8si requires a processor interface circuit pack. A port on a digital line circuit pack is required to provide the MS interface This applica- tion also requires an ADU and a port on a data line circuit pack or a modem and an analog line circuit pack. R8r: The BX.25 connection requires a PGATE circuit pack. MFC enhance- mentsDS1 interface 24/32 and call classifier circuit packs. Ta b l e 4 9 .Additional Hardware to Use Features — Continued Feature Hardware Continued on next page
DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 Technical Specifications 215 Additional Hardware to Use Features MF shuttle DS1 interface 24/32 and call classifier circuit packs. MF signaling No additional hardware required. Misoperations handlingNo additional hardware required. Modem pooling (Category A only)One pooled modem circuit pack per 2 integrated conversion resources provided. Each combined conversion resource requires 1 port on the digital line circuit pack, 1 port on an analog line circuit pack, and an analog modem and data module or 7400 terminal. Multi-appear- ance preselec- tion and preferenceMultiappearance telephone. Multimedia appli- cations server interface (MASI) (Category A only)DS1 interface 24/32 and call classifier circuit packs. Multimedia call appearances (Category A only)Requires no additional hardware. Multimedia call early answer on vectors and sta- tions (Category A only)Requires no additional hardware. Multimedia call handling (MMCH) (Cate- gory A only)Multimedia interface circuit pack and multimedia voice conditioner circuit pack to provide multimedia call processing. A digital line port and BRI data port per multimedia complex. Table 49.Additional Hardware to Use Features — Continued Feature Hardware Continued on next page
Technical Specifications 216 Additional Hardware to Use Features DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 Multiple call han- dling on request or forced (forced is Category A only)A multi-appearance set is required. Multimedia call redirection to MM endpoint (Cate- gory A only)Requires no additional hardware. Multimedia data conferencing via expansion ser- vices module (ESM) (Category A only)ESM adjunct device (terminates T.120 protocol and provides data conference control and data distribution), TN2207 modified PRI cir- cuit pack, TN787 multimedia interface circuit pack, a cable to con- nect the TN2207 to the TN787 Multimedia hold, conference, transfer, and drop (Category A only)Requires no additional hardware. Multimedia multiple-port net- work (Category A only)Requires no additional hardware. Multimedia queu- ing with voice announcement (Category A only)Requires no additional hardware. Ta b l e 4 9 .Additional Hardware to Use Features — Continued Feature Hardware Continued on next page
DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 Technical Specifications 217 Additional Hardware to Use Features Multimedia ser- vice-link architec- ture support of voice/data mode (Category A only)Requires no additional hardware. Music-on-hold accessMusic source and 1 port on an auxiliary trunk or analog line circuit pack are required. A 909-type voice coupler is required if the system is not FCC-registered (United States only). A music source and 1 port on a TN746B or TN468B or later Analog Line circuit pack. A KS23395, L4 Music-on-Hold interface to convert a loop start port into a Music-on-Hold port. The port must be administered for this pur- pose. Also, a 909-type voice coupler is required if the music source is not FCC-registered (United States only). France: a port on the TN2183 Analog Line circuit pack and the 122A Music-on-Hold inter- face unit (wall-mounted). Names registra- tion A PMS can connect through a data module and a port on a digital line circuit pack, or through an ADU and a port on a data line circuit pack. A journal printer requires a data module and a port on a digital line circuit pack, or an ADU and a port on a data line circuit pack. National ISDN-1 DS1 Interface circuit pack. Native support of 6402D display terminalRequires no additional hardware. Network access — publicOne port on a CO or DIOD trunk circuit pack or 1 port on a DS1/E1 interface circuit pack or tie trunk circuit pack. Night Service - hunt group, night console service and night station serviceNo additional hardware required other than a button to activate and deactivate the feature. Table 49.Additional Hardware to Use Features — Continued Feature Hardware Continued on next page
Technical Specifications 218 Additional Hardware to Use Features DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 Night service — trunk answer from any stationRinging device and 1 port on an analog line circuit pack. Night service - trunk groupNo additional hardware required other than a button to activate and deactivate the feature. NT interface on TN556B/CRequires no additional hardware. NT QSIG peer protocolRequires no additional hardware. Off-premises data extensionsTrunk data module or DCP extender and 1 port on a digital line cir- cuit pack or DS1 circuit pack. Off-premises sta- tionCross-connecting capabilities and 1 port on an analog line circuit pack or DS1 circuit pack. Outbound call management (OCM) (Cate- gory A only)Requires a TN2182B tone-clock circuit pack. Can also use an older tone-clock as long as a TN744C or newer tone detector circuit pack is in the system. PC application software transla- tion exchange (PASTE) (Cate- gory A only)A port on a digital line or BRI line circuit pack connected through a Personal Computer configured with the PC/PBX, PC/ISDN, or Pas- sageWay circuit pack and application software to an appropriate voice terminal. PC interface (hardware varies depending on the configuration group used)Group 2: 7400-series DCP terminals, PC/PBX interface card, an IBM-compatible PC (6300 or 6300 Plus with DOS 3.1 or later, or PC/XT with PC-DOS 3.1 or later. 448K or more of RAM is recom- mended on PCs running integrated software applications. Group 3: 7500-series ISDN-BRI Voice Terminal, up to 4 PC/ISDN expansion cards, an IBM-compatible PC (6300, 6300 Plus, PC/XT, PC/AT, PS/2, or Compaq), and DOS 3.1 or later. Ta b l e 4 9 .Additional Hardware to Use Features — Continued Feature Hardware Continued on next page
DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 Technical Specifications 219 Additional Hardware to Use Features PC/PBX connec- tion A port on a digital line circuit pack for each PC/PBX connected. Personal central office line (PCOL)A port on a central office trunk circuit pack for each trunk assigned as a PCOL. Personal station accessDigital line ports and a digital voice terminal. Personalized ringingNo additional hardware required. Power Failure TransferOne emergency transfer panel per 5 or 6 trunks assigned to Power Failure Transfer, depending on panel used. The following panels are available: n808A Panel — Serves up to 5 failure transfer terminals. The unit provides automatic ground start or loop start nZ1A Panel — Serves up to 6 power failure transfer terminals. A ground-start key is required at each preselected voice terminal when ground-start trunks are used PRI Converter DASS - 1 TN464F DS1/E1 circuit pack and 1 TNCCSC-1 circuit pack. DPNSS - 1 TN464F DS1/E1 circuit pack and 1 TNCCSC-2 circuit pack. BRI - 1 TN464F DS1/E1 circuit pack and 1 TNPRI/BRI circuit pack. Priority Calling No additional hardware required. Privacy - Atten- dant LockoutNo additional hardware required. Privacy - Manual ExclusionNo additional hardware required. Table 49.Additional Hardware to Use Features — Continued Feature Hardware Continued on next page
Technical Specifications 220 Additional Hardware to Use Features DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 Property Man- agement System (PMS)For all except R8r, either: 1. Using a digital line port and a data module, or 2. Using a digital line port and an ADU For R8r, either: 1. A packet data circuit pack cross-connected to a port on a data line circuit pack, connected to a second data line circuit pack port and then to an ADU, or 2. A packet data circuit pack cross-connected to a port on a data line circuit pack connected to either a BRI line circuit pack connected to a 7500 Data Module or to a digital line connected to a data module. Data line circuit pack with an ADU or a data module and port on a digital line circuit pack. Public Network Call PriorityNo additional hardware required. Pull Transfer No additional hardware is required in a stand-alone configuration. In a network environment, the TGU/TGE tie trunks (TN497) are the only trunks that support the flash signaling necessary to complete the pull transfer operation between systems. QSIG Global NetworkingSame as ISDN-PRI. See ISDN-PRI. QSIG call offer (Category A only) QSIG call com- pletion (Cate- gory A only)No additional hardware is required. Ta b l e 4 9 .Additional Hardware to Use Features — Continued Feature Hardware Continued on next page