Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 System Description Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 Cabinets, Carriers, and Circuit Packs 121 Circuit Packs and Related Hardware A special grounding latch on each circuit pack protects it from electrostatic discharge during installation and removal. !CAUTION: A wrist strap must be worn when handling any circuit pack. A ground jack is provided on each cabinet for this purpose. Color coding Port circuit packs and slots are now gray rather than purple. During the transition between the old and new schemes, gray and purple circuit packs are interchangeable. Control circuit packs and slots are white. Types of Circuit Packs NOTE: The purple-colored and white-colored circuit packs and slots are being replaced by circuit packs and slots labeled with gray and white rectangles, respectively. A label with a solid gray rectangle indicates a port slot/circuit pack. A label with an outlined white rectangle indicates a control slot/circuit pack. nPort: colored purple or labeled with a gray rectangle and can accept any purple or gray-labeled circuit pack nControl: colored white or labeled with an outlined white rectangle and can accept only a circuit pack assigned to that slot nService: colored purple or labeled with a gray rectangle; is a special type of circuit pack that does not have an I/O connector Four types of circuit packs are installed in carriers: 1. Port circuit packs provide links between analog and digital lines, trunks, networks, external communications equipment, and the TDM bus and packet bus. These circuit packs install in any gray port slot. 2. Control circuit packs include processor, memory, network control, disk control, tape control, protocol interfaces, duplication, and maintenance. These circuit packs install in dedicated white slots in the control carrier and do not operate in any other slots.
Cabinets, Carriers, and Circuit Packs 122 Circuit Packs and Related Hardware DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 3.Service circuit packs produce and detect tones, synthesize speech, classify calls, record announcements, and allow system access for administration and troubleshooting. These circuit packs install in any port slot. 4. Power Converter circuit packs supply DC voltages to port, control, and service circuit packs. These circuit packs install in dedicated white slots only. Port Circuit Packs The components common to all port circuit packs are: nBus buffers nSanity and control interface (Random Access Memory (RAM) nNetwork processing elements (NPEs) or switch conferencing for Time Division Multiplexing (TDM) in concentration highway (SCOTCH NPE) Bus Buffers The bus buffers are the digital interface between the TDM bus wires on the backplane and the circuitry on the circuit pack. They receive or transmit on either of the two 8-bit TDM buses. SAKI The sanity and control interface (SAKI) is the circuit pack interface to the TDM bus. It receives control channel information from the bus and sends the information to the microprocessor. Conversely, the microprocessor sends control channel information to the SAKI, which sends it to the TDM bus. The SAKI also controls status indicator LEDs on the circuit pack, initiates start-up procedures when power is turned on, checks the circuit pack’s microprocessor for sanity, and re-initializes the microprocessor in case of problems. If a problem is detected, the SAKI takes the defective circuit pack out of service either on command from the Switch Processing Element (SPE) or when the SAKI determines that interference is present in control time slots on the circuit pack. Microprocessor with External RAM The microprocessor performs all low-level functions such as scanning for changes and relay operations. In general, the microprocessor carries out commands received from the SPE and reports status changes to the SPE. Some port circuit packs contain more than 1 microprocessor. The external RAM stores control channel information and port-related information.
DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 Cabinets, Carriers, and Circuit Packs 123 Circuit Packs and Related Hardware Network Processing Elements (NPEs) The NPEs, or a high-density SCOTCH, perform conference and gain-adjustment functions. An NPE (under control from the microprocessor) can connect a port circuit to any TDM bus time slot. Each port circuit pack has from 1 to 6 NPEs or a SCOTCH NPE. International Consolidation (I-CON) TN791, TN2793, TN2214 and TN2215 are new circuit packs for export outside of the United States and Canada. The circuit packs are functionally identical to the TN746B, TN793, and TN2224 circuit packs. International Consolidation circuit packs work in Offer Category A systems outside of the US and Canada and in Offer Category B (DEFINITY BCS or Guestworks) systems. When an International Consolidation circuit pack is inserted into a Category A system with the Location field set to 1 (US and Canada), the system fails to recognize the circuit pack and generates a major alarm (error code 276). Table 33. I-CON Circuit Packs US and Canada Category A International Category A or B, US and Canada Category B only Description TN746B TN79116 port analog line TN793/TN793B TN2793/TN2793B24 port analog line TN2224B TN2214B24 port digital line TN2183 TN2215 16 port analog line (Australia, China, and Western Europe only) TN464F (US and Canada Category A only)TN2464DS1
Cabinets, Carriers, and Circuit Packs 124 Circuit Packs and Related Hardware DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 Circuit Packs in DEFINITY Table 34 lists the circuit packs by apparatus code. After the table, circuit pack functions are detailed. Table 45 lists the available adjuncts. After the table, information briefly describes the adjunct functions. Table 34. Circuit Packs and Circuit Modules Apparatus Code Name Type 631DA1 AC Power Unit (Multi-Carrier Cabinet) AC Power Unit (MCC) (+5V, 60A) Power 631DB1 AC Power Unit (MCC) (-48V/-5V,8A) Power 644A1 (Replaced by 649A in R7 and later systems) DC Power Unit (MCC) (+5V, 60A)Power 645B1 (Replaced by 649A in R7 and later systems) DC Power Unit (MCC) (-48V, 8A) Power 649A DC Power Unit (MCC) (-5, +5, -48V) (in a port carrier, a single 649A replaces both the 644A1 and 645B1 power units)Power 650AAC Power Unit (CMC) Power 1217A AC Power Supply for Single-Carrier Cabinets Power 676CDC Power Supply (Single Carrier Cabinet) Power 982LSCurrent Limiter for si only (PPN) Power CFY1BCurrent Limiter for r only Power ED-1E546DEFINITY AUDIX R3 (Circuit-Pack Assembly) (being replaced by ED-1E568)Application ED-1E546CallVisor ASAI/DEFINITY LAN Gateway R1 (Circuit-Pack Assembly) (being replaced by J58890MA-1)Application Continued on next page
DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 Cabinets, Carriers, and Circuit Packs 125 Circuit Packs and Related Hardware ED-1E568 DEFINITY AUDIX R4 (Circuit Pack Assembly) (replaces ED-1E546)Application J58890MA-1Multi Application Platform DEFINITY (Circuit Pack Assembly) List 2 for Call Visor, ASAI, LAN Gateway R2 List 10 for IP Trunk List 20 for CV ASAI, CentreVu Computer Telephony, BCMS Vu List 30 for IP Solutions Application NAA1Fiber Optic Cable Adapter for R7 or later (CMC) TN417 Auxiliary Trunk (replaced by TN763D)Trunk TN419BTone-Clock (Italy, Australia and the United Kingdom, replaced by TN2182B)Control TN420B/ CTone Detector (replaced by TN2182B or TN744D)Service TN429B DIOD Trunk (Japan) Trunk TN429C CO Trunk (with CAMA) Trunk TN429D DIOD/CO Trunk (with CAMA and US/Japan ICLID) Trunk TN433Speech Synthesizer (Italian) Service TN436BDirect Inward Dialing Trunk (Australia) Trunk TN437Tie Trunk (Australia, replaced by TN760D) Trunk TN438BCentral Office Trunk (Australia) Trunk TN439Tie Trunk (Australia and Japan) Trunk TN447Central Office Trunk (United Kingdom, replaced by TN2147C)Trunk TN457 Speech Synthesizer, British EnglishService Table 34. Circuit Packs and Circuit Modules — Continued Apparatus Code Name Type Continued on next page
Cabinets, Carriers, and Circuit Packs 126 Circuit Packs and Related Hardware DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 TN458 Tie Trunk for the United Kingdom (replaced by TN760D)Trunk TN459B Direct Inward Dialing Trunk for the United KingdomTrunk TN464C/D/E/F DS1 Interface (T1 (24-Channel) or E1 (32-Channel)) Trunk TN465B/C Central Office Trunk (Multi-Country, 16 kHz PPM) Trunk TN467 Analog Line for the United Kingdom and Australia (replaced by TN2183)Line TN468B Analog Line for the United Kingdom and Australia (replaced by TN2183) (16 ports)Line TN479 Analog Line (16 ports) Line TN497 Tie Trunk for ItalyTN497Tie Trunk (Italy, TGU/TGE/TGI) Trunk TN553 Packet Data LineLine TN556B/C/D ISDN Line (12-BRI-S-NT) Line TN566BMulti-Function Board (See ED-1E546) Application TN567Multi-Function Board (See ED-1E546) Application TN568 DEFINITY AUDIX 4.0 Voice Mail System (see ED-1E568)Application TN570B/CExpansion InterfaceNetwork TN572 Switch-Node Clock for the r model only Control TN573B Switch-Node Interface for the r model only Control TN574DS1 Converter (replaced by TN1654) (r model V2 and later) Port TN577Packet Gateway (r model only) Port TN722B DS1 Tie Trunk (replaced by TN767B/C/D/E) (24 ports) Trunk TN725B Speech Synthesizer, United States EnglishService TN726B Data Line (8 ports) Line Table 34. Circuit Packs and Circuit Modules — Continued Apparatus Code Name Type Continued on next page
DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 Cabinets, Carriers, and Circuit Packs 127 Circuit Packs and Related Hardware TN735 MET Line (4 ports) Line TN742Analog Line (8 ports) (replaced by TN746B) Line TN744B/C/DCall Classifier Tone Detector, Multi-CountryService TN746B Analog Line (US and Canada Offer A Only) (16 ports) Line TN747B Central Office Trunk(8) Trunk TN748B/C/D Tone Detector (replaced by TN2182B) Service TN750B/C AnnouncementService TN753B Direct Inward Dialing Trunk (8 ports) Trunk TN754B/CDigital Line (8-4w DCP) Line TN755BNeon Power Unit (all models except csi) Power TN756Tone Detector/Generator (XE) (replaced by TN2182B) Service TN758 Pooled Modem (2 ports) Port TN760D/E Tie Trunk (4 ports) Trunk TN762B Hybrid Line (8 ports) Line TN763B/C/D Auxiliary Trunk (4 ports) Trunk TN765 Processor Interface (replaced by TN794 and TN799/TN799B) for si onlyControl TN767B/C/D/E DS1 Interface (T1, 24 Channel) Trunk TN768 Tone-Clock (replaced by TN2182B) Control TN769 Analog Line (8 ports) (Neon) Line TN771B/C/D Maintenance Test Service TN772 Duplication Interface (R6 LAN si bus and earlier) Control TN775B/C Maintenance (EPN) Service TN776Expansion Interface (si only) Network TN777B Network Control (R6 and earlier) (replaced by TN794) for si only Control Table 34. Circuit Packs and Circuit Modules — Continued Apparatus Code Name Type Continued on next page
Cabinets, Carriers, and Circuit Packs 128 Circuit Packs and Related Hardware DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 TN778 Packet Control (R6 and some earlier) for si only (replaced by TN794)Control TN780 Tone Clock (all models except csi, Stratum 3) Control TN786B Processor (G3V4si and earlier) Service TN787F/G/H/J/KMultimedia InterfaceService TN788BVoice Conditioner (Multimedia) Service TN789 Radio ControllerPort TN790Processor (R6 si and some earlier) Control TN790B Processor (R7 si and later) Control TN791Analog Guest Line (16 Port, International Offers or US and Canada Category B only)Line TN792Duplication Interface (for TN790B Processor Circuit Packs, si only) Control TN793B24-Port 2-Wire Analog Line with Caller ID Line TN794 Network Control/Packet Interface for si only (R7 and laterControl TN794/TN2400 Sandwich Assembly Board for R7si and later upgrades when the Control Cabinet is being reusedControl TN795 Processor (DEFINITY ONE) Control TN797 Analog CO Trunk and Line (Combo 8 port similar to TN747B)Line TN798BProcessor (csi) Control TN799/TN799B Control LAN (C-LAN) InterfaceNetwork TN801 MAPD (LAN Gateway Interface)MAPD for LAN Gateway Interface for CTI, CallVisor, PC/LAN (see J58890MA)Application TN802/TN802B MAPDIP Interface Assembly for IP Solutions, including IP Trunking and IP Softphones (see J58890MA)Application Table 34. Circuit Packs and Circuit Modules — Continued Apparatus Code Name Type Continued on next page
DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 Cabinets, Carriers, and Circuit Packs 129 Circuit Packs and Related Hardware TN803 MAPD for CTI, CentreVu CT, BCMS Vu, Ursa Minor Centaurus (see J58890MA)Application TN1648B System Access and Maintenance (SYSAM) for r only Control TN1650BMemory (32MB) for r only Control TN1654 DS1 Converter, T1 (24-Channel) and E1 (32-Channel)Trunk TN1655Packet Interface (r model V1 and later) Control TN1656 Tape Drive (R8r and earlier) (replaced by TN2211 in R8 and later) Control TN1657Disk Drive (r model V1 and later) Control TN2135Analog Line for Italy (16 Port, replaced by TN2183)) Line TN2136Digital Line (2-Wire DCP 8 ports, replaced by TN2181 and TN2224/Tn2214)Line TN2138Central Office Trunk (Italy, Loop Start) Trunk TN2139Direct Inward Dialing Trunk (Italy) Trunk TN2140B Tie Trunk (Hungary and Italy, 4 wire E&M) Port TN2144Analog Line (The Netherlands, replaced by TN2183) (16 port)Line TN2146Direct Inward Dialing trunk (Belgium and The Netherlands)Trunk TN2147CCentral Office Trunk (without PPM, replaces TN447) Trunk TN2149 Analog Line for Belgium (replaced by TN2183) (16 port) Line TN2169 Alarm Board (See ED-1E546) Service TN2170Ethernet Alarm Board (See ED-1E546) Service TN2180 Analog Line for Spain and Germany (replaced by TN2183)Line TN2181Digital Line (16-ports DCP-2-Wire) Line Table 34. Circuit Packs and Circuit Modules — Continued Apparatus Code Name Type Continued on next page
Cabinets, Carriers, and Circuit Packs 130 Circuit Packs and Related Hardware DEFINITY Enterprise Communications Server Release 8.2 System Description 555-233-200 Issue 1 April 2000 TN2182BTone-Clock (Tone Detector, Tone Generator and Call Classifier (replaces TN419B, TN748B/C/D, TN756 and TN768 (superset of TN744D)Control TN2183Analog line, Multi Country with DSLAC (replaces TN467, TN460, TN2144, TN2146)Line TN2184DIOD Trunk (Germany) Trunk TN2185BISDN (4-Wire S/T-TE Interface, 8 ports) Line/Trunk TN2198ISDN Line (4-Wire BRI-U-NT, 8 ports) Line TN2199Central Office Trunk (Russia) Trunk TN220250 Hz Balanced Ring Generator (France) (MCC) Power TN2207DS1 Interface (T1 (24-Channel) and E1 (32 Channel) with DS1 Adjunct Interface) Trunk TN2208 Multi-Function Board (see ED-1E546, CallVisor ASAI/DEFINITY LAN Gateway R1 (Circuit-Pack Assembly))Multi- function TN2209 Tie Trunk (Russia) Trunk TN2210 Tone Generator (1780 Hz) Service TN2211 Optical Drive (R8, replaces TN1656) Control TN2214BDigital Line (24-Port, 2-Wire DCP, International Offers or US and Canada Category B only)Line TN2215/TN2183Analog line (16-Port Programmable impedance, International Offers or US and Canada Category B only)Line TN2224BDigital Line (24-Port, 2-Wire DCP) Line TN2238 ATM Interface (Multi-Mode Fiber, Port Network Connectivity, replaced by TN2305 in R7)Trunk or Application TN2242Digital Trunk (Japan - 2MB TTC) Trunk TN2301Logic Switch (for R6r or later, Survivable Remote EPN) Service Table 34. Circuit Packs and Circuit Modules — Continued Apparatus Code Name Type Continued on next page