    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 System Description Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Cabinets, Carriers, and Circuit Packs 
    81 Carriers in MCCs 
    NOTE:
    In the following illustrations, a balanced ring generator (BRG) is shown below the 
    power unit slot in certain carriers. This means the power unit slot can include a 50 
    Hz BRG when optioned for France.
    J58890AH Control Carrier (si model)
    A representative J58890AH control carrier is shown below. 
    Figure 34.J58890AH Control Carrier (si model) (J58890AH Control Carrier (si model)) 
    (Front) 
    ccdfr8ah LJK 121399
    Z100A1
    blanks
    or
    631DA1631DB1
    or
    649A
    T
    N
    7
    9
    2T
    N
    2
    4
    0
    0
    or
    b
    l
    a
    n
    k
    Z
    1
    0
    0
    D
    or
    b
    l
    a
    n
    k
    T
    N
    7
    7
    1
    D T
    N
    7
    7
    6
    or
    T
    N
    5
    7
    0 T
    N
    7
    9
    4 Z
    1
    0
    0
    CT
    N
    7
    7
    6
    or
    T
    N
    5
    7
    0T
    N
    7
    5
    5
    B T
    N
    7
    9
    0
    BT
    N
    2
    1
    8
    2
    B
    AUTO
    A
    OVERIDES
    P
    E
    Lucent
    103577450
    Lucent
    98DR07125243TN792DUPL  INTERF
    ACE
    C
    A
    R
    D
    I
    N
    U
    S
    E
    T
    N
    7
    9
    9
    BBI
    LINK
    TRMT
    RCVALARMS
    EMER TR MAJ
    MIN
    WRN
    ACK
    ON
    OFF AUTO
    B
    l
    a
    n
    kB
    l
    a
    n
    kB
    l
    a
    n
    kB
    l
    a
    n
    kB
    l
    a
    n
    kB
    l
    a
    n
    kB
    l
    a
    n
    kB
    l
    a
    n
    kB
    l
    a
    n
    kB
    l
    a
    n
    k 
    						
    							Cabinets, Carriers, and Circuit Packs 
    82 Carriers in MCCs 
    DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    This carrier has dedicated white-colored circuit pack slots that always contain specific 
    control circuit packs. Dual-color slots may contain any port circuit pack or the designated 
    white circuit packs (such as an EI or power unit). AC or DC power units supply power to 
    the carrier. Table 14 describes the connectors on the rear of the control carrier.
    NOTE:
    The TN776 is not shipped in the R7si and later systems. It can remain in the 
    system if packet endpoints and the C-LAN (TN799) are not used.
    .Table 14. Control-Carrier Connectors
    Connector Function
    1 to 9 (A1 to A9)  25-pair connectors provide interfaces between port circuit 
    packs and the cross-connect field or fiber transceiver
    AUX (Auxiliary) Interface for alarms, attendant console power, emergency 
    power transfer panels, and an internal modem (for remote 
    maintenance)
    Processor interface 
    (standard reliability 
    only)Connects directly to the PI circuit pack. Provides a BX.25 
    protocol interface for communication between the circuit pack 
    and external DCE equipment.
    Data communications 
    equipmentConnects the processor to CDR equipment, a system printer, 
    or an external modem (for remote maintenance). This 
    connector can be used with any reliability option.
    Terminal Connects a management terminal to the processor in 
    standard reliability systems. In critical reliability systems, 
    connects a terminal to the processor in its control carrier.
    Duplication option 
    terminalUsed in high and critical reliability systems to connect an 
    administration terminal to the active processor from the 
    duplication interface slot position
    P1 Provides position indicator of the carrier, power to fans, and 
    access to alarm and control circuits
    P2 Provides control signals to the carrier
    Continued on next page 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Cabinets, Carriers, and Circuit Packs 
    83 Carriers in MCCs 
    J58890AJ  Duplicated Control Carrier 
    (si model)
    The Duplicated Control Carrier (J58890AJ) has dedicated white circuit pack slots that 
    always contain specific control circuit packs. It can also be populated with port circuit 
    packs or dual-colored slots that may be populated with port circuit packs or designated 
    white circuit packs (such as an expansion Interface or power unit).
    AC or DC power units located at each end of the Duplicated Control Carrier supply power 
    to the carrier. See Figure 35 for a representative example. See Table 15 for the 
    Duplicated Control Carrier rear connector descriptions.
    Figure 35.Duplicated Control Carrier (si model) (J58890AJ) (Front) 
    ccdfr8aj LJK 121399
    Z100A1
    blanks
    or
    631DA1631DB1
    or
    649A
    T
    N
    7
    9
    2T
    N
    2
    4
    0
    0
    or
    b
    l
    a
    n
    k
    Z
    1
    0
    0
    D
    or
    b
    l
    a
    n
    k
    T
    N
    7
    7
    1
    D
    B
    l
    a
    n
    k
    T
    N
    7
    7
    6
    or
    T
    N
    5
    7
    0 T
    N
    7
    9
    4
    B
    l
    a
    n
    k
    Z
    1
    0
    0
    C
    B
    l
    a
    n
    k
    T
    N
    7
    7
    6
    or
    T
    N
    5
    7
    0T
    N
    7
    5
    5
    B T
    N
    7
    9
    0
    BT
    N
    2
    1
    8
    2
    B
    AU TO
    A
    OVERIDES
    P
    E
    Lucent
    103577450
    Lucent
    98DR07125243TN792DUPL  INTERF
    ACE
    C
    A
    R
    D
    I
    N
    U
    S
    EC
    A
    R
    D
    I
    N
    U
    S
    E
    T
    N
    7
    9
    9
    BBI
    LINK
    TRMT
    RCVALARMS
    EMER TR MAJ
    MIN
    WRN
    ACK
    ON
    OFF AUTO
    B
    l
    a
    n
    kB
    l
    a
    n
    kB
    l
    a
    n
    kB
    l
    a
    n
    kB
    l
    a
    n
    kB
    l
    a
    n
    kB
    l
    a
    n
    kB
    l
    a
    n
    kB
    l
    a
    n
    kB
    l
    a
    n
    k 
    						
    							Cabinets, Carriers, and Circuit Packs 
    84 Carriers in MCCs 
    DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    NOTE:
    The TN776 is not shipped in the R7si and later systems. It can remain in the 
    system if packet endpoints and the C-LAN (TN799) are not used.
    Ta b l e  1 5 .J58890AJ Duplicated Control Carrier (si model) Connectors
    Connector Function
    1 to 9 (B1 to B9) 25-pair connectors provide interfaces between port circuit packs and 
    the cross-connect field or fiber transceiver
    Terminal Connects a management terminal to the processor in its Duplicated 
    Control Carrier
    P1 Provides position indicator of the carrier and access to alarm and 
    control circuits 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Cabinets, Carriers, and Circuit Packs 
    85 Carriers in MCCs 
    J58890AP  Processor Carrier (r model)
    The Processor Carrier contains only dedicated slots for control circuit packs composing 
    the Switch Processing Element (SPE). It does 
    not contain port circuit pack slots. See 
    Figure 36 for a representative example.
    AC or DC power units located at each end of the Processor Carrier supply the power to 
    the carrier. The Processor Carrier always contains 3 memory circuit packs and 1 packet 
    interface circuit pack. See Table 16 for the Processor Carrier rear connector descriptions.
    Figure 36.Processor Carrier (r model) (J58890AP) (Front)
    ccdfr8ap LJK 121399
    Z100A1
    blanks
    or
    631DA1631DB1
    or
    649A
    T
    N
    1
    6
    4
    8T
    N
    1
    6
    5
    7 T
    N
    7
    8
    0
    or
    T
    N
    2
    1
    8
    2 T
    N
    1
    6
    5
    0
    BT
    N
    1
    6
    5
    0
    BT
    N
    1
    6
    5
    0
    B Z
    1
    0
    0
    CT
    N
    1
    6
    5
    5T
    N
    2
    2
    1
    1 U
    N
    3
    3
    0
    BU
    N
    3
    3
    1
    BU
    N
    3
    3
    2
    C
    OVERRIDEB SPE
    AU TOA
    TN2211 OPTICAL DRIVECAUTION:DO
    B
    l
    a
    n
    kB
    l
    a
    n
    kB
    l
    a
    n
    kB
    l
    a
    n
    kB
    l
    a
    n
    kB
    l
    a
    n
    kB
    l
    a
    n
    k 
    						
    							Cabinets, Carriers, and Circuit Packs 
    86 Carriers in MCCs 
    DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
      
    Ta b l e  1 6 .J58890AP Processor Carrier (r model) Connectors
    Connector Function
    Clock (stratum-3) Provides an interface to a stratum-3 clock for digital frame timing. 
    This is not a time-of-day clock
    AUX (Auxiliary) Provides an interface for customer alarms, attendant console 
    power, emergency power-transfer panels, and an internal-modem 
    interface for remote maintenance
    Terminal, active Connects a management terminal to the system access and 
    maintenance (SYSAM) circuit pack in the active Processor Carrier
    Terminal, standby Used only in Duplicated Processors to connect a management 
    terminal to the standby processor carrier
    P1 Provides position indicator of the carrier and access to alarm and 
    control circuits
    P2 Provides control signals to the carrier
    Continued on next page 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Cabinets, Carriers, and Circuit Packs 
    87 Carriers in MCCs 
    J58890BB Port Carrier
    A Port Carrier contains the following circuit packs: 
    nPort slot locations 1 to 20 for the port circuit packs. A dedicated slot contains an 
    optional tone-clock circuit pack used for Port Carriers in the B position of an EPN 
    cabinet in critical reliability systems. Slot 2 contains an optional EI or ATM Interface 
    circuit pack
    nPower unit service slots in which power unit circuit packs or maintenance circuit 
    packs can install
    nAC or DC power units located at each end of the carrier
    See Figure 37 for a representative example. See Table 19 for the Port Carrier rear 
    connector descriptions.
    Table 17.J58890BB Port Carrier Connectors
    Connector Function
    1 to 20 Ports interfacing between circuit pack slots and the cross-connect field or 
    fiber transceiver
    P1 Provides position indicator of the carrier and access to alarm and control 
    circuits 
    						
    							Cabinets, Carriers, and Circuit Packs 
    88 Carriers in MCCs 
    DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Figure 37.J58890BB Port Carrier (Front)
    Port
    Port/Service(BRG)
    BTONE
    CLO CKEXPN
    INTFCEXPN
    INTFC2319567891011121314151618172041PO W ER U NI TSERVICEPOWER UNITPower Unit
    6
    3
    1
    D
    B
    1
    or
    6
    4
    9
    A Z
    1
    0
    0
    A
    1
    B
    L
    A
    N
    K
    SZ
    1
    0
    0
    C
    B
    L
    A
    N
    K or
    6
    3
    1
    D
    A
    1
    T
    N
    5
    7
    0
    BT
    N
    5
    7
    0
    B T
    N
    2
    1
    8
    2
    ServiceService
    ccdf0003 RPY 081297 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Cabinets, Carriers, and Circuit Packs 
    89 Carriers in MCCs 
    J58890AF  Expansion Control Carrier
    The Expansion Control Carrier contains an EI or ATM Interface circuit pack in port slots 1 
    and 2. It is used in a fiber optic cabling path to another cabinet or the CSS in the same 
    cabinet. These slots may contain optional port circuit packs. See Figure 38 for a 
    representative example.
    The Expansion Control Carrier also contains port slots 3 to 19 and the AC or DC power 
    units. The maintenance and tone-clock circuit packs are also shown. An optional neon 
    power unit can be in slots 18 and 19. See Table 18 for the Expansion Control Carrier rear 
    connector descriptions.
    Figure 38. Expansion Control Carrier (J58890AF) (Front)
    A
    T
    N
    5
    7
    0
    BT
    N
    5
    7
    0
    B T
    N
    2
    1
    8
    2
    Port/Service
    (BRG)
    T
    N
    7
    7
    5
    B
    PortServiceService
    TO NE -
    CLO CKEXPN
    INTF CEXPN
    INTFC23195678910111213141516181741M AINTENANCEPOW ER UNIT PO W ER UNITPower Unit
    6
    3
    1
    D
    B
    1
    or
    6
    4
    9
    A
    Z
    1
    0
    0
    A
    1
    B
    L
    A
    N
    K
    S
    Z
    1
    0
    0
    C
    B
    L
    A
    N
    K or
    6
    3
    1
    D
    A
    1
    ccdf0004 RPY 081297 
    						
    							Cabinets, Carriers, and Circuit Packs 
    90 Carriers in MCCs 
    DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Table 18. Expansion Control Carrier (J58890AF) Connectors
    Connector Function
    1 and 2 (A1 and A2) Provides a fiber-optic cable interface to an expansion interface 
    (EI) circuit pack in slot 1
    1 or a copper cable interface for a DS1 
    Converter
    1.In systems using ATM-PNC, the fiber connectors for the OC-3/STM-1 interfaces to the
    ATM switches are located on the faceplates of the TN2305/TN2306 circuit packs. 1 to 19 (A1 to A19) Provides interfaces between port circuit packs and the 
    cross-connect field 
    AUX  Provides interfaces for customer alarms, attendant console 
    power, and emergency power transfer panels
    TERMINAL Connects a management terminal to the maintenance circuit 
    pack in an expansion control carrier
    P1 Provides position indicator of the carrier and access to alarm 
    and control circuits
    P2 Connects ringing voltage from the ring generator to the carrier 
    and produces control signals
    Continued on next page 
    						