    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 8.2 System Description Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Cabinets, Carriers, and Circuit Packs 
    101 Carriers in SCCs 
    J58890H  Port Cabinet 
    The Port Cabinet is located in the PPN and in EPNs. It contains ports and an interface to 
    an Expansion Control Cabinet. The Port Cabinet has optional port circuit packs in port 
    slots 1 to 18. In a critical-reliability system, these can include a tone-clock circuit pack in 
    slot 1 and expansion interface circuit packs in slots 2 and 3. A neon power unit can be 
    installed in slots 17 and 18. See Figure 45 for a representative example.
    The AC or DC power supply, located at the right side of the cabinet, supplies power to the 
    cabinet. See Table 23 for the Port Cabinet rear connector descriptions.
    Figure 45.Port Cabinet (J58890H) (Front) 
    POWER SUPPLYBTON E-
    CLOCK
    T
    N
    5
    7
    0T
    N
    5
    7
    0 T
    N
    2
    1
    8
    2
    B
    POWER UNIT
    1617 18155678910111213143421
    676B
    or
    WP-91153
    (BRG) Port/Service Port Port/Service
    EXPN
    INT FCEXPN
    INTFC
    1
    5
    8
    P
    B
    L
    A
    N
    K 1
    5
    8
    J
    B
    L
    A
    N
    K1
    5
    8
    P
    B
    L
    A
    N
    K
    Service
    ccdf0008 RPY 081297 
    						
    							Cabinets, Carriers, and Circuit Packs 
    102 Carriers in SCCs 
    DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Ta b l e  2 3 .Port Cabinet (J58890H) Connectors
    Connector Function
    2 to 3 (B2 to B3) EI port that provides an interface for the fiber optic cable between 
    the EI circuit pack in slot 2
    1 or 3 and another port network (PN)
    1 to 18 (B1 to B18) Interface ports between circuit packs and the cross-connect field
    1.In systems using ATM-PNC, the fiber connectors for the OC-3/STM-1 interfaces to the
    ATM switches are located on the faceplates of the TN2305/TN2306 circuit packs. 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Cabinets, Carriers, and Circuit Packs 
    103 Carriers in SCCs 
    J58890T  Compact Modular Cabinet 
    (csi model)
    The Compact Modular Cabinet is an economical, small-footprint alternative to a Single- 
    Carrier Cabinet. It can mount on a wall or on the floor, and uses an AC-only power supply. 
    The control carrier contains 2 control slots: the processor has to be in slot 1 and the 
    tone-clock in slot 2. Slots 3 to 10 can contain optional port and service circuit packs. See 
    the figure below.
    Figure 46.J58890T Compact Modular Cabinet (csi model) (Left Side)
    scdfleft KLC 110497
    MAJ
    MIN 
    						
    							Cabinets, Carriers, and Circuit Packs 
    104 Carriers in SCCs 
    DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    The connectors on the right side of the cabinet are shown in Figure 47. 1 to 10 25-pair 
    connectors interface between port circuit packs and the cross-connect field or a cable 
    access panel.
    Figure 47. CMC (J58890T) (Right Side)
    scdfrf2 KLC 061097 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Cabinets, Carriers, and Circuit Packs 
    105 Carriers in SCCs 
    Up to three Compact Modular Cabinets can be combined in a single installation. Port and 
    service circuit packs fill all ten slots in the second and third cabinets. The first cabinet (A) 
    installs in the middle position, the second cabinet (B) installs on the top, and the third 
    cabinet (C) installs on the bottom. See Figure 48. 
    Figure 48. Typical Compact Modular Cabinet (csi model) Installation (Front)
    Floorindf3cmcKLC110497
    A
    C
    B 
    						
    							Cabinets, Carriers, and Circuit Packs 
    106 Minimum Cabinet Configurations 
    DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Minimum Cabinet Configurations
    Minimum cabinet configurations in MCCs and in stacks of Single-Carrier Cabinets serve 
    as the foundations on which to build cabinets in direct-connect systems and Center Stage 
    Switch (CSS)-connected systems. 
    NOTE:
    The CMC cannot be duplicated but may be connected to other CMC cabinets.
    The following are the minimum required circuit packs:
    nTo n e - c l o c k  
    nExpansion interface (EI)
    nExpansion port network (EPN) maintenance 
    The following criteria describe a minimum cabinet configuration:
    nCabinet interconnection options (direct-connect and CSS-connected) 
    nSystem duplication options (standard reliability, high reliability, and critical 
    reliability)
    nTraffic engineering to determine the number of port networks
    Table 24, Table 25 and Table 26 list the minimum required carriers and circuit packs in 
    PPN and EPN cabinets or cabinet stacks.
    Table 24. Minimum Requirements for PPN Cabinet
    Duplication Option Connection OptionControl 
    CarriersSwitch Node 
    CarriersTo n e
    Clocks
    Standard reliability direct or ATM 1 0 1
    CSS 1 0 or 1
    1
    1.The1st SN is located in the PPN (normal) or EPN. The 2nd and 3rd are located in
    an EPN to support up to 44 PNs.
    1
    High reliability direct or ATM 2 0 2
    CSS 2 0 or 1
    12
    Critical reliability
    (Category A only)direct or ATM 2 0 2
    CSS 2 0 or 2
    12
    ATM Network Duplication
    (Category A only)ATM 1 0 2 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Cabinets, Carriers, and Circuit Packs 
    107 Minimum Cabinet Configurations 
    Table 25. Minimum Requirements for an EPN Cabinet
    Duplication 
    Option Connection OptionExpansion 
    Control 
    CarriersSwitch 
    Node 
    CarriersTo n e -  
    ClocksAT M  o r  
    Expansion
    Interfaces 
    In EPN
    Standard 
    reliabilitydirect or ATM 1 0 1 Equals 
    number of 
    PNs
    CSS 1 0 or 1
    1
    1.The1st SN is located in the PPN (normal) or EPN. The 2nd and 3rd are located in an
    EPN to support up to 44 PNs. Up to 3 EPNs can be directly-connected.
    11
    High 
    Reliabilitydirect or ATM 1 0 1 Equals 
    number of 
    PNs
    CSS 1 0 or 1
    111
    Critical 
    reliability
    (Category A 
    only)direct or ATM 1 0 2 Twice 
    number of 
    PNs
    CSS 1 0 or 2
    122
    ATM 
    Network 
    Duplication
    (Category A 
    only)ATM 1 0 2 2 
    						
    							Cabinets, Carriers, and Circuit Packs 
    108 Minimum Cabinet Configurations 
    DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Standard Reliability Systems
    The standard reliability configuration is available in all systems, but it is the only one that 
    is available for the DEFINITY ECS csi. It has no duplicated hardware, and includes: 
    nOne control carrier
    nOne tone-clock circuit pack per PN
    nPort networks interconnected by single fiber pairs
    Optional carriers in the MCCs are port carriers that can be added as required. In R7r or 
    later, an SN carrier can be added to Position
     E as required. Optional port carriers are 
    determined by traffic engineering. Table 26. Minimum Requirements for a Two-PN Multi-Carrier Cabinet EPN 
    (R7r and later)
    Duplication 
    OptionConnection
    OptionControl
    CarriersSwitch Node 
    Carriers Tone-ClocksAT M  o r  
    Expansion
    Interfaces
    Standard 
    reliabilitydirect or 
    ATM10 2 4
    CSS 1 0 2 2
    High reliability direct or 
    ATM10 2 4
    CSS 1 0 2 2
    Critical reliability
    (Category A only)direct or 
    ATM10 4 8
    CSS 1 0 4 4
    ATM Network 
    Duplication
    (Category A only)ATM 1 0 4 4 
    						
    							DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    Cabinets, Carriers, and Circuit Packs 
    109 Minimum Cabinet Configurations 
    High Reliability Systems
    High reliability systems require:
    nDuplicate control carriers in the PPN cabinet
    nDuplicate PPN tone-clock circuit packs, one in each Control Carrier.
    nOne tone-clock circuit pack per EPN
    nPort networks interconnected by single fiber pairs
    — The PPN requires duplicate connectivity to the switch node
    — The switch node requires duplicates switch node clocks. The switch node 
    carrier is provided in the PPN cabinet for a CSS-connected DEFINITY ECS r.
    — For ATM inter-PN connectivity, the PPN requires two links to the ATM switch 
    (Category A only).
    Critical Reliability Systems (Category A only)
    Critical reliability provides full duplication of the SPE, inter-PN connectivity, and 
    Tone-Clocks. These systems require:
    nDuplicate control Carriers in the PPN cabinet and EPN cabinet
    nDuplicate tone-clock circuit packs in the PPN cabinet and EPN cabinets
    nPort networks interconnected by duplicated cables
    — Direct connect systems use duplicate inter-PN connectivity for each PN (EI 
    and fiber)
    — Switch connect systems duplicate the CSS and duplicate PN-to-SN 
    connectivity (one PN fiber to each of the Switch Node Carriers in the 
    duplicated SN)
    — For a R7r or later ATM inter-PN connectivity the ATM links to the ATM switch 
    or switches are duplicated. The ATM switches may or may not be duplicated. 
    This depends on the ATM switch that is being used.
    nDuplicate Switch Node Carriers in the CSS
    nPacket R7 and later systems will require the Maintenance/Test circuit pack.
    NOTE:
    Critical reliability systems require the duplication of carriers in PPN and EPN 
    cabinets and cabinet stacks.  
    						
    							Cabinets, Carriers, and Circuit Packs 
    110 Direct Connect Cabinet Configurations 
    DEFINITY Enterprise Communications Server Release 8.2
    System Description  555-233-200  Issue 1
    April 2000
    ATM Network Duplication (Category A only)
    DEFINITY ECS R8r and later ATM Network Duplication systems will require the full 
    duplication of the inter-PN connectivity and the Tone-Clocks. These systems require:
    nDuplicate Tone-Clocks in each Expansion Port Network (EPN)
    — Both the Expansion Control Carrier and the Port Carrier are required in each 
    EPN, with a Tone-Clock and an ATM interface residing in each of the two 
    carriers. The MCC and SCC stack are compatible EPNs. The CMC EPN is not 
    supported.
    — If the PPN has only one SPE complex located in the A carrier of the MCC 
    cabinet, the recommendation is for the ATM interfaces to be placed in slot 2 of 
    both the B and C carriers. Another alternative would be to place the ATM 
    interfaces in slots 2 and 3 of the B carrier. This will result in the loss of 
    complete connectivity duplication (because of a common power failure group) 
    and the full advantage that is attainable from the ATM Network Duplication.
    nDuplicate inter-PN connectivity
    — The ATM links to the ATM switch will be duplicated for inter-PN connectivity
    — The ATM switch or switches may or may not be duplicated, depending on the 
    ATM switch that is being used.
    nA TN771 facility test pack is required in each PPN of an R8r system. In an ATM 
    network duplication R8r system, the TN771 is required both in the PPN and in each 
    EPN.
    nDirect Connect systems are not supported.
    Direct Connect Cabinet Configurations
    A direct connect system configuration could connect cabinets directly to each other via 
    fiber optic or copper pairs. There is no intervening switch or hub. A direct connect system 
    can contain up to 3 port networks, including 1 PPN and 2 EPNs (a port network can 
    consist of a Single-Carrier Cabinet, a stack of Single-Carrier Cabinets, or a single 
    Multi-Carrier Cabinet).  
    						