Page 881
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 857 Music Sources 17 Music Sources This screen defines music sources for Tenant Partitions. Each music source defined on the screen can be used by one or more Tenant Partitions. However, a partition may have only one music source. NOTE: If you use equipment that rebroadcasts music or other copyrighted materials, you may be required to obtain a copyright license from, or pay fees to, a third party such...
Page 882
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 858 Music Sources 17 Ty p e If you entered a value in Music/Tone on Hold on the Feature-Related System Parameters screen, that value will appear in this field. Port Enter the auxiliary trunk or analog port address of the music source. Duplicates are not allowed. This field appears only if you entered music in Type. Description Enter a description of the administered music source. This field appears...
Page 883
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 859 Packet Gateway Board 17 Packet Gateway Board Use this screen to administer the Packet Gateway (PGATE) circuit pack. NOTE: The PGATE screen is used with G3r configurations. Field descriptions for page 1 Screen 169. Packet Gateway Board Board Location Enter the slot location of the PGATE circuit pack. Name Application Display-only field that shows the communications protocol used to transmit messages...
Page 884
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 860 Partition Route Table 17 Partition Route Table Use this table to identify routing for partition groups associated with an ARS analysis entry. Screen 170. Partition Route Table PGN 1 (through PGN 8) Enter the routing for each partition group associated with each route index number. Valid entries Usage 1 to 640Specifies the route pattern used to route the call r1 to r32Specifies the remote home...
Page 885
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 861 Personal CO Line Group 17 Personal CO Line Group Use this screen to set up a personal central office line trunk group. Screen 171. Personal CO Line Group The following fields are unique to this screen. Analog Loss Group This field determines which administered 2-party row in the loss plan applies to this trunk group if the call is carried over an analog signaling port in the trunk group. Coverage...
Page 886
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 862 Personal CO Line Group 17 Digital Loss Group This field determines which administered 2-party row in the loss plan applies to this trunk group if the call is carried over a digital signaling port in the trunk group. Security Code Trunk Direction Trunk Port Trunk Name Valid entries Usage 1 to 17Shows the values from the loss plan and tone plan. Valid entries Usage 4 digits Enter a 4-digit code that...
Page 887
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 863 Personal CO Line Group 17 Field descriptions for page 2 Screen 172. Personal CO Line Group Ext This display-only field shows the extension of phones that have a CO Line button. Name This display-only field shows the name assigned to phones that have a CO Line button. Field descriptions for page 3 Administrable timers for Personal CO Line groups appear on Field descriptions for page 3. Refer to ‘‘...
Page 888
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 864 Pickup Group 17 Pickup Group This screen implements call pickup groups with up to 50 extensions per group. A pickup group is a group of users authorized to answer calls to a phone extension within that group of users. A phone extension number can only belong to one pickup group. Field descriptions for pages 1 and 2 Screen 173. Pickup Group Group Number A display-only field when the screen is...
Page 889
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 865 PRI Endpoint 17 Extended Group Number This field appears only when the Group Call Pickup field is set to flexible on the Feature-Related System Parameters screen. The extended group is a collection of pickup groups that can answer calls from other pickup groups in the same extended group. Ext Enter the extension assigned to a station. Name This display-only field shows the name assigned to the...
Page 890
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 866 PRI Endpoint 17 Screen 174. PRI Endpoint Extension A display-only field when the screen is accessed using an administration command such as change or display. Name Identifies the endpoint. (Starting) Port Enter the seven-character starting port of the PRI Endpoint. Valid entries Usage blank This is the extension number used to access the PRI endpoint. Enter a valid unassigned extension number when...