Page 861
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 837 Multifrequency-Signaling-Related System Parameters 17 ANI for PBX This field appears only when Outgoing Call Type is group-ii-mfc or mfe. MFE Type This field only appears when Incoming Call Type is mfe and the Outgoing Call Type is mfe or none. Maintenance Call Type Next ANI Digit This field appears when Outgoing Call Type is group-ii-mfc. Valid entries Usage 2 to 15 Enter the PBX identification...
Page 862
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 838 Multifrequency-Signaling-Related System Parameters 17 Test Call Extension Interdigit Timer (sec) Specify the maximum number of seconds the switch will wait for the first forward signal (digit) to arrive, and for subsequent digits to arrive. Intercept returns to the calling party if this timer expires. Maximum Resent Requests Received Signal Gain (-Loss) (dB) Transmitted Signal Gain (-Loss) (dB) Valid...
Page 863
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 839 Multifrequency-Signaling-Related System Parameters 17 Outgoing Forward Signal Present Timer (sec) This field appears only when the value of Outgoing Call Type is group-ii-mfc. Outgoing Forward Signal Absent Timer (sec) This field appears only when the content of Outgoing Call Type is group-ii-mfc. Multifrequency Signaling Incoming Intercept Treatment Overlap Sending on Link-to-Link Tandem Calls A...
Page 864
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 840 Multifrequency-Signaling-Related System Parameters 17 Private Group II Permissions and Public Interworking Convert First Digit End-of-ANI To Collect All Digits Before Seizure This field appears only when Outgoing Call Type is group-ii-mfc or mfe. Request Incoming ANI (non-AAR/ARS) This field only applies if the incoming call via the R2-MFC trunk is terminating to a local station on this PBX. Valid...
Page 865
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 841 Multifrequency-Signaling-Related System Parameters 17 Forward Cycle Timer (sec) This field appears only if Incoming Call Type is mfe and Outgoing Call Type is mfe or none. Backward Cycle Timer (sec) This field appears only if Incoming Call Type is mfe and Outgoing Call Type is mfe or none. Incomplete Dial Timer (sec) This field appears only if Incoming Call Type is mfe and Outgoing Call Type is...
Page 866
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 842 Multifrequency-Signaling-Related System Parameters 17 Group II Called Party Category Enter the type of group II signals that should be used on the outgoing R2-MFC call Note: For India, the ANI can be requested without the call category information. Use COR for Calling Party Category Indicates the category to send with ANI if requested on an outgoing R2-MFC call. Outgoing Shuttle Exchange Cycle Timer...
Page 867
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 843 Multifrequency-Signaling-Related System Parameters 17 Field descriptions for page 2 The fields on Page 2 define call category and ANI information. For India, the ANI can be requested without the call category information. Screen 165. Multifrequency-Signaling-Related Parameters screen Request Call Category at Start of Call Indicates that the Send-ANI backward signal requesting for the caller-category...
Page 868
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 844 Multifrequency-Signaling-Related System Parameters 17 Number of Incoming ANI Digits Number of Outgoing ANI Digits This field applies to Russian shuttle trunks, and MFC and MFE trunks. Truncate Station Number in ANI This field applies to Russian shuttle trunks, and MFC and MFE trunks. ANI Source for Forwarded Calls Valid entries Usage 0 to 15Enter the number of ANI digits for incoming MFC calls. Valid...
Page 869
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 845 Multifrequency-Signaling-Related System Parameters 17 Address Digits Include End-of-Digits Signal Indicates that an outgoing forward Group I end-of-digit signal is always sent after completion of address digits upon request from the Central Office for outgoing calls. Call Category for Vector ii-digits Allows you to use the call category digit as the ii-digits on call vector steps. Request CPN at...
Page 870
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 846 Multifrequency-Signaling-Related System Parameters 17 ANI Not Available You must enter a value if the ANI for PBX field is blank Field descriptions for page 3 The fields shown on Page 3 of the Multifrequency-Signaling-Related System Parameters screen define the meaning of MFC tones for calls originated at the CO. Refer to ‘‘ Definitions of Group I, II, A, and B signals’’ on page 851 for more...