Screen reference 
827 Mode Code Related System Parameters 
17
External Coverage
This value defines a mode code that the switch sends when an external caller tries 
to reach a user at another extension and the call goes to the user’s voice mail 
coverage.
Refresh MW Lamp
This value defines a mode code that the switch sends during a system level 3 or 
higher reset that requests the VMS to refresh the Message Waiting (MW)...

Page 852

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1.1
June 2000
Screen reference 
828 Mode Code Related System Parameters 
17
OFF
Sending Delay
VMS Hunt Group Extension
A check is made to verify that a valid hunt group extension is entered, but a check 
is not made to verify that the hunt group members are VMI extensions.
Remote VMS Extensions - First 
You can administer this field if the Mode Code for Centralized Voice Mail field on 
the System-Parameters Customer-Options screen is set...

Page 853

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1.1
June 2000
Screen reference 
829 Modem Pool Group 
17
Modem Pool Group
There are two types of conversion resources for Modem Pooling. The first type, 
an integrated conversion resource, is a circuit pack that emulates a Trunk Data 
Module connected to a 212A-type modem. Two conversion resources are on each 
circuit pack.
The second type, a combined conversion resource, is a separate Trunk Data 
Module and modem administered as a unit....

Page 854

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1.1
June 2000
Screen reference 
830 Modem Pool Group 
17
Screen 163. Modem Pool Group — Combined screen if Group Type is combined
Group Number
A display-only field when the screen is accessed using an administration 
command such as 
add or change.
Group Type
This field designates what physical model pool you are going to.
Receiver Responds to Remote Loop
This field appears only when the Group Type field is 
integrated.
Valid entries...

Page 855

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1.1
June 2000
Screen reference 
831 Modem Pool Group 
17
Modem Name
Indicates the name of the modem pool. This field appears only when the Group 
Type field is 
combined.
Hold Time (min)
Enter the maximum number of minutes that a conversion resource in the group 
may be held while a call waits in a queue or reserved after Data Call 
Preindication.
Send Space Disconnect 
This field appears only when the Group Type field is 
integrated....

Page 856

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1.1
June 2000
Screen reference 
832 Modem Pool Group 
17
CF-CB Common
This field appears only when the Group Type field is 
integrated.
Direction
Enter the direction of the call for which modem pool will operate. This field 
appears only when the Group Type field is 
combined.
The following fields (Speed, Duplex, and Synchronization) cannot be filled out 
for the “integrated” pooled modem screens but can be assigned on the “combined”...

Page 857

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1.1
June 2000
Screen reference 
833 Modem Pool Group 
17
Speed
Enter the communication speed in bits per second of the conversion resources in 
the group. Enter one to three speeds separated by slashes (for example, 
300/1200/2400) to indicate a maximum of three running speeds.
Duplex
Indicates the duplex mode of the conversion resources in the group.
Synchronization
Indicates the synchronization mode of the conversion resources in the...

Page 858

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1.1
June 2000
Screen reference 
834 Modem Pool Group 
17
Circuit Pack Location
Enter the port associated with the conversion resource on the integrated modem 
pool circuit pack.
For example, 01A0612 is in cabinet 01, carrier A, slot 06, and circuit number 
(port) 12.
PORT PAIR ASSIGNMENTS are optional on “combined” pooled modem screens 
only.
Analog Digital 
Enter the port numbers of the modem/TDM pair in a conversion resource.
NOTE:
Two...

Page 859

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1.1
June 2000
Screen reference 
835 Multifrequency-Signaling-Related System Parameters 
17
Multifrequency-Signaling-Related
System Parameters
This screen sets the system parameters associated with multifrequency signaling. 
Screen 164 on page 835
 appears when Incoming Call Type is group-ii-mfc and 
Outgoing Call Type is 
none. Screen 165 on page 843 appears when both 
Incoming Call Type and Outgoing Call Type are 
group-ii-mfc.
Screen...

Page 860

DEFINITY ECS Release 8.2
Administrator’s Guide  555-233-506  Issue 1.1
June 2000
Screen reference 
836 Multifrequency-Signaling-Related System Parameters 
17
Incoming Call Type
This field defines the signal type that a CO uses to place an incoming call to the 
PBX.
ANI Prefix
This field appears only when Outgoing Call Type is 
group-ii-mfc or mfe.
Outgoing Call Type
This field defines the signal type that the PBX uses to place an outgoing call into a 
CO.
Valid entries Usage
group-ii-mfc
  If the value...