DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 827 Mode Code Related System Parameters 17 External Coverage This value defines a mode code that the switch sends when an external caller tries to reach a user at another extension and the call goes to the user’s voice mail coverage. Refresh MW Lamp This value defines a mode code that the switch sends during a system level 3 or higher reset that requests the VMS to refresh the Message Waiting (MW)...
Page 852
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 828 Mode Code Related System Parameters 17 OFF Sending Delay VMS Hunt Group Extension A check is made to verify that a valid hunt group extension is entered, but a check is not made to verify that the hunt group members are VMI extensions. Remote VMS Extensions - First You can administer this field if the Mode Code for Centralized Voice Mail field on the System-Parameters Customer-Options screen is set...
Page 853
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 829 Modem Pool Group 17 Modem Pool Group There are two types of conversion resources for Modem Pooling. The first type, an integrated conversion resource, is a circuit pack that emulates a Trunk Data Module connected to a 212A-type modem. Two conversion resources are on each circuit pack. The second type, a combined conversion resource, is a separate Trunk Data Module and modem administered as a unit....
Page 854
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 830 Modem Pool Group 17 Screen 163. Modem Pool Group — Combined screen if Group Type is combined Group Number A display-only field when the screen is accessed using an administration command such as add or change. Group Type This field designates what physical model pool you are going to. Receiver Responds to Remote Loop This field appears only when the Group Type field is integrated. Valid entries...
Page 855
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 831 Modem Pool Group 17 Modem Name Indicates the name of the modem pool. This field appears only when the Group Type field is combined. Hold Time (min) Enter the maximum number of minutes that a conversion resource in the group may be held while a call waits in a queue or reserved after Data Call Preindication. Send Space Disconnect This field appears only when the Group Type field is integrated....
Page 856
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 832 Modem Pool Group 17 CF-CB Common This field appears only when the Group Type field is integrated. Direction Enter the direction of the call for which modem pool will operate. This field appears only when the Group Type field is combined. The following fields (Speed, Duplex, and Synchronization) cannot be filled out for the “integrated” pooled modem screens but can be assigned on the “combined”...
Page 857
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 833 Modem Pool Group 17 Speed Enter the communication speed in bits per second of the conversion resources in the group. Enter one to three speeds separated by slashes (for example, 300/1200/2400) to indicate a maximum of three running speeds. Duplex Indicates the duplex mode of the conversion resources in the group. Synchronization Indicates the synchronization mode of the conversion resources in the...
Page 858
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 834 Modem Pool Group 17 Circuit Pack Location Enter the port associated with the conversion resource on the integrated modem pool circuit pack. For example, 01A0612 is in cabinet 01, carrier A, slot 06, and circuit number (port) 12. PORT PAIR ASSIGNMENTS are optional on “combined” pooled modem screens only. Analog Digital Enter the port numbers of the modem/TDM pair in a conversion resource. NOTE: Two...
Page 859
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 835 Multifrequency-Signaling-Related System Parameters 17 Multifrequency-Signaling-Related System Parameters This screen sets the system parameters associated with multifrequency signaling. Screen 164 on page 835 appears when Incoming Call Type is group-ii-mfc and Outgoing Call Type is none. Screen 165 on page 843 appears when both Incoming Call Type and Outgoing Call Type are group-ii-mfc. Screen...
Page 860
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 836 Multifrequency-Signaling-Related System Parameters 17 Incoming Call Type This field defines the signal type that a CO uses to place an incoming call to the PBX. ANI Prefix This field appears only when Outgoing Call Type is group-ii-mfc or mfe. Outgoing Call Type This field defines the signal type that the PBX uses to place an outgoing call into a CO. Valid entries Usage group-ii-mfc If the value...