Page 871
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 847 Multifrequency-Signaling-Related System Parameters 17 Tones from CO on Incoming Forward Calls — Group I Message codes 11 to 15 display. (Numbers 1 through 10 are assigned to the digits of the destination telephone number.) Assign a meaning to each code. Refer to ‘‘ Definitions of Group I, II, A, and B signals’’ on page 851 for signal type. Tones from CO on Incoming Forward Calls — Group II Message...
Page 872
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 848 Multifrequency-Signaling-Related System Parameters 17 Tones from CO on Incoming Forward Calls — Group I Message codes 11 to 15 display. (Numbers 1 through 10 are assigned to the digits of the destination telephone number.) Assign a meaning to each code. Tones to CO on Incoming Backward Calls — Group B This field does not appear if the Do Not Send Group B Signals to CO field is y. Message codes...
Page 873
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 849 Multifrequency-Signaling-Related System Parameters 17 Field descriptions for page 4 The fields shown on this page define the meaning of MFC tones for calls originated at the PBX. Refer to ‘‘ Definitions of Group I, II, A, and B signals’’ on page 851 for more information. Page 4 of the Multifrequency-Signaling-Related System Parameters screen only appears if Outgoing Call Type is group-ii-mfc or...
Page 874
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 850 Multifrequency-Signaling-Related System Parameters 17 Tones to CO on Outgoing Forward Calls — Group II Message codes between 1 and 15 display. Assign a meaning to each code. Each entry can only appear once in the group II column. Tones from CO on Outgoing Backward Calls — Group A Message codes between 1 and 15 display. Assign a meaning to each code. Valid entries Usage attendant Refer to...
Page 875
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 851 Multifrequency-Signaling-Related System Parameters 17 Tones from CO on Outgoing Backward Calls — Group B Message codes between 1 and 15 display. Assign a meaning to each code. Refer to ‘‘ Definitions of Group I, II, A, and B signals’’ on page 851 for signal type. Definitions of Group I, II, A, and B signals Group I signals Group I signals are a set of forward signals generated by the originating...
Page 876
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 852 Multifrequency-Signaling-Related System Parameters 17 end-of-dial This signal is used when open numbering is used on DID calls. The CO sends this signal to indicate the end-of-dial digits and the switch responds with a request for a group II signal. end-of-digits This signal is sent by the origination switch that makes outgoing calls, sends digits, and receives a next-digit group A signal from the...
Page 877
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 853 Multifrequency-Signaling-Related System Parameters 17 busy-rt-attd If the switch receives this signal on DID calls, the call terminates at an attendant if the called extension is busy or at the called extension if it is not busy. This signal is used on DID calls. data-call This signal is treated the same as the data-verify signal except that it does not require a terminating extension to be a data...
Page 878
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 854 Multifrequency-Signaling-Related System Parameters 17 toll-operator This signal, used in China, is treated as a normal subscriber signal. See the normal definition. Group A signals Group A signals are backward signals generated by the destination switch. send-ani The CO sends this signal to request calling-party category and sends additional signals to request ANI digits. This signal is sent to the...
Page 879
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 855 Multifrequency-Signaling-Related System Parameters 17 last-2-digits The switch sends this signal to adjust the outpulsing pointer so that the last 3 digits can be resent. This signal is used on DOD calls. last-3-digits The switch sends this signal to adjust the outpulsing pointer so that the last 4 digits can be resent. This signal is used on DOD calls. next-digit The switch sends this signal to...
Page 880
DEFINITY ECS Release 8.2 Administrator’s Guide 555-233-506 Issue 1.1 June 2000 Screen reference 856 Multifrequency-Signaling-Related System Parameters 17 free This signal indicates that the called party is idle. On DID calls, the signal is sent to the CO to indicate that the called party is idle and the call is terminated successfully. If the switch receives this signal on DOD calls, it connects the trunk to the calling party. intercept This signal indicates that the called party number is not in...