Page 111

DEFINITY Enterprise Communication Server Release 8.2
Reports Guide  555-233-505  Issue 1
April 2000
Traffic Data Analysis 
3-69 DS1 Link Performance Detailed Log Report 
3
Table 3-15. DS1 Link Performance Measurements Detailed Log Report 
Field Description
Date
The date of the 15-minute interval.
Time
The end ing  time for the 15-minute interval.
ES
Errored  Second. The numb er of errored  sec ond s for the sp ec ified  interval 
(maximum of 900). An errored  sec ond  is any sec ond  in whic h one or...

Page 112

DEFINITY Enterprise Communication Server Release 8.2
Reports Guide  555-233-505  Issue 1
April 2000
Traffic Data Analysis 
3-70 DS1 Link Performance Detailed Log Report 
3
CSSControlled  Slip  Sec ond s. The numb er of sec ond s (maximum of 255) with one 
or more c ontrolled  slip s (a rep lic ation or d eletion of a DS1 frame b y the 
receiver).
LOFC
Loss of Frame Count. 
The ac c umulation of the numb er of times a loss of 
frame is d ec lared (maximum of 255). A loss of frame is d ec lared  when there...

Page 113

DEFINITY Enterprise Communication Server Release 8.2
Reports Guide  555-233-505  Issue 1
April 2000
Traffic Data Analysis 
3-71 DS1 Converter Reports 
3
DS1 Converter Reports
This sec tion d esc rib es p erformanc e measurements for the four fac ilities 
assoc iated  with a DS1 Converter b oard. It inc lud es the DS1 Converter Link 
Performanc e Measurements Summary Rep ort and  the DS1 Converter Link 
Performanc e Log  Rep ort. These rep orts are availab le only on the G3r server.
The DS1 Converter b...

Page 114

DEFINITY Enterprise Communication Server Release 8.2
Reports Guide  555-233-505  Issue 1
April 2000
Traffic Data Analysis 
3-72 DS1 Converter Reports 
3
nBursty-Errored  Sec ond. Any sec ond  that c ontains from 2 to 319 error 
events.
nSeverely-Errored  Sec ond . Any sec ond  that c ontains 320 or more error 
events.
nFa i le d  Se c o n d . A state that exists when ten or more c onsec utive 
severely-errored  sec ond s are d etec ted . A Failed  Sec ond  state is c leared  
when no severely-errored...

Page 115

DEFINITY Enterprise Communication Server Release 8.2
Reports Guide  555-233-505  Issue 1
April 2000
Traffic Data Analysis 
3-73 DS1 Converter Reports 
3
This c ommand is only availab le on the G3r mod el. In add ition, the user c an reset 
all software c ounters assoc iated  with the sp ec ified  DS1 Converter c irc uit p ac k 
fac ility. The Counted Since
 time is also reset and  the Number of Valid Intervals
 
c ount is set to zero.
To d isp lay the DS1 Converter Performanc e Measurements Summary:
1....

Page 116

DEFINITY Enterprise Communication Server Release 8.2
Reports Guide  555-233-505  Issue 1
April 2000
Traffic Data Analysis 
3-74 DS1 Converter Reports 
3
Table 3-16. DS1 Converter Performance Measurements Summary Report 
Field Description
Counted 
SinceThe d ate and  time when the assoc iated  measurement c ounters are 
c leared  or the DS1 Converter fac ility is ad ministered . The c ounters are 
set to 0 and  start ac c umulating  d ata when the system is ad ministered  
or re-initialized . The c urrent...

Page 117

DEFINITY Enterprise Communication Server Release 8.2
Reports Guide  555-233-505  Issue 1
April 2000
Traffic Data Analysis 
3-75 DS1 Converter Reports 
3
Screen 3-21 shows one p ag e of a typ ic al DS1 Fac ility Log  Rep ort. This rep ort 
shows errors in fifteen-minute intervals, over the last twenty-four hour period , and  
usually extend s for several pag es. The head ings and  typ e of information shown 
here d o not c hang e on sub sequent p ag es.
Screen 3-21. DS1-Facility Log Report 
CategoryThe...

Page 118

DEFINITY Enterprise Communication Server Release 8.2
Reports Guide  555-233-505  Issue 1
April 2000
Traffic Data Analysis 
3-76 DS1 Converter Reports 
3
Table 3-17. DS1 Converter Performance Measurements 
Detailed Log Report 
Field Description
Date
The time and  d ate of the c urrent rep ort.
Counted 
SinceThe start time and date when the associated measurement counters are 
cleared or the DS1 Converter facility is administered.
Date and 
TimeThe d ate and  end  time of the 15-minute interval.
ES
Errored...

Page 119

DEFINITY Enterprise Communication Server Release 8.2
Reports Guide  555-233-505  Issue 1
April 2000
Traffic Data Analysis 
3-77 Emergency Access Calls Report 
3
Emergency Access Calls Report
The Emerg enc y Ac c ess Calls rep ort trac ks emerg enc y c alls by extension, event, 
type of c all, and  time of d ay. This rep ort p rints in the system journal p rinter with 
name, time and  event c od e (attend ant c risis alert).
Command
To d isp lay the Emerg ency Ac cess Calls rep ort:
1. Type list emergency...

Page 120

DEFINITY Enterprise Communication Server Release 8.2
Reports Guide  555-233-505  Issue 1
April 2000
Traffic Data Analysis 
3-78 Emergency Access Calls Report 
3
Screen
Screen 3-22 shows a typ ic al sc reen for the Emergenc y Ac c ess Calls rep ort. 
Table 3-18
 describes the data presented in the Emergency Access Calls report.
Screen 3-22. Emergency Access Calls report
Table 3-18. Emergency Access Calls report 
Field Description
Extension The extension where the c risis alert orig inated .
Event The...