Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 161

DEFINITY ECS Release 8.2 Installation, Upgrades, 
and Additions for Compact Modular Cabinets  555-233-118  Issue 1
April 2000
Upgrading R6csi/R7csi to R8csi 
3-5 Upgrade to Release 8 
3
Upgrade to Release 8
Check SPE
Ty p e  status system 1 
and press En t e r to c hec k the health of the system. 
Check Link Status
1. Enter display communication-interface links
 and press En t e r. Rememb er 
or write d own all enab led  links
2. Type status link
 
number and  p ress En t e r for eac h enab led  link.
3....

Page 162

DEFINITY ECS Release 8.2 Installation, Upgrades, 
and Additions for Compact Modular Cabinets  555-233-118  Issue 1
April 2000
Upgrading R6csi/R7csi to R8csi 
3-6 Upgrade to Release 8 
3
!CAUTION:
If you d o not d isab le Alarm Orig ination, the system may g enerate 
alarms, resulting  in unnec essary troub le tic kets.
3. Type neither 
in the Alarm Origination to OSS Numbers
 field and 
p ress 
En t e r . 
NOTE:
Disab ling  alarm orig ination p revents the system from generating  
alarms, thus p...

Page 163

DEFINITY ECS Release 8.2 Installation, Upgrades, 
and Additions for Compact Modular Cabinets  555-233-118  Issue 1
April 2000
Upgrading R6csi/R7csi to R8csi 
3-7 Upgrade to Release 8 
3
Save Announcements (if necessary)
NOTE:
The TN750C Announc ement c irc uit p ac k stores announc ements in 
nonvolatile memory; saving  the announc ements to a flashc ard  is op tional.
1. If the PPN c ontains a TN750/B Announc ement c irc uit p ac k, typ e display 
announcements
 and  p ress 
En te r.
2. If administered...

Page 164

DEFINITY ECS Release 8.2 Installation, Upgrades, 
and Additions for Compact Modular Cabinets  555-233-118  Issue 1
April 2000
Upgrading R6csi/R7csi to R8csi 
3-8 Upgrade to Release 8 
3
3. Insert the Release 8 g eneric  p rog ram c ard  (orang e c ard) into the TN798B.
4. Power up  the c ab inet. The system automatic ally load s the Release 8 
software.
Upgrade Software
NOTE:
If you installed  the TN798B, skip  this step .
1. Insert the Release 8 g eneric  p rog ram c ard  (orang e c ard) into the...

Page 165

DEFINITY ECS Release 8.2 Installation, Upgrades, 
and Additions for Compact Modular Cabinets  555-233-118  Issue 1
April 2000
Upgrading R6csi/R7csi to R8csi 
3-9 Upgrade to Release 8 
3
Administer the System
1. Log in as craft
 at the login:
 p rompt. 
2. Check for the Translation Corruption Detected
 message before 
p roc eed ing  with the up g rad e. If c orruption is d etec ted , refer to 
‘‘Translation Corruption Detected’’
 in Chapter 5, ‘‘Troubleshooting an 
Upgrade’’ to c orrec t the p rob lem....

Page 166

DEFINITY ECS Release 8.2 Installation, Upgrades, 
and Additions for Compact Modular Cabinets  555-233-118  Issue 1
April 2000
Upgrading R6csi/R7csi to R8csi 
3-10 Upgrade to Release 8 
3
2. Type the appropriate start and stop information in the Change Day
, 
Month
, Date
, Time
, and  Increment
 (for example, 1:00
 eq uals one hour) 
field s for eac h rule. 
NOTE:
You c an c hang e any rule exc ep t rule 0 (zero). You c annot delete a 
d aylig ht saving s rule if it is in use on either the Loc ations or...

Page 167

DEFINITY ECS Release 8.2 Installation, Upgrades, 
and Additions for Compact Modular Cabinets  555-233-118  Issue 1
April 2000
Upgrading R6csi/R7csi to R8csi 
3-11 Upgrade to Release 8 
3
4. The c ursor is p ositioned  on the Month:
 field . Typ e the c urrent month in 
Eng lish (January throug h Dec emb er). See Table 3-4
 for Eng lish month 
names. After the month is entered, p ress 
Ta b to move to next field
5. The c ursor is p ositioned  on the Day of the Month:
 field . Typ e the d ay 
of month (1...

Page 168

DEFINITY ECS Release 8.2 Installation, Upgrades, 
and Additions for Compact Modular Cabinets  555-233-118  Issue 1
April 2000
Upgrading R6csi/R7csi to R8csi 
3-12 Upgrade to Release 8 
3
2. Notify the switc h ad ministrator that for any p revious log in names and  
p assword s that still exist, the p assword s exp ire in 24 hours. When 
changed, the new login names and passwords must conform to the 
following  req uirements:
As b efore, a log in name must have 3 to 6 alp hanumeric  c harac ters. A 
p...

Page 169

DEFINITY ECS Release 8.2 Installation, Upgrades, 
and Additions for Compact Modular Cabinets  555-233-118  Issue 1
April 2000
Upgrading R6csi/R7csi to R8csi 
3-13 Upgrade to Release 8 
3
Enable Customer Options and Alarm Origination
1. Get the DOSS order number of the upgrade from the project manager and 
ask the reg ional Customer Software Ad ministration to c omp lete the step s 
in the shad ed  b ox. See ‘‘Where to Call for Tec hnic al Sup p ort’’ on p ag e -xix
 
for telep hone numb ers.
NOTE:
As p...

Page 170

DEFINITY ECS Release 8.2 Installation, Upgrades, 
and Additions for Compact Modular Cabinets  555-233-118  Issue 1
April 2000
Upgrading R6csi/R7csi to R8csi 
3-14 DEFINITY AUDIX Power Procedures 
3
Return Equipment
1. Return rep lac ed  eq uip ment to Luc ent Tec hnolog ies ac c ord ing  to the 
req uirements outlined  in:
BCS/Material Log istic s, MSL/Attend ed  Stoc king  Loc ations
Method s and Proc ed ures for Basic  Material Returns
2. Retain the old  translation c ard  for up  to 10 b usiness days...
Start reading Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual

Related Manuals for Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual

All Lucent Technologies manuals