Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 161
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Upgrading R6csi/R7csi to R8csi 3-5 Upgrade to Release 8 3 Upgrade to Release 8 Check SPE Ty p e status system 1 and press En t e r to c hec k the health of the system. Check Link Status 1. Enter display communication-interface links and press En t e r. Rememb er or write d own all enab led links 2. Type status link number and p ress En t e r for eac h enab led link. 3....
Page 162
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Upgrading R6csi/R7csi to R8csi 3-6 Upgrade to Release 8 3 !CAUTION: If you d o not d isab le Alarm Orig ination, the system may g enerate alarms, resulting in unnec essary troub le tic kets. 3. Type neither in the Alarm Origination to OSS Numbers field and p ress En t e r . NOTE: Disab ling alarm orig ination p revents the system from generating alarms, thus p...
Page 163
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Upgrading R6csi/R7csi to R8csi 3-7 Upgrade to Release 8 3 Save Announcements (if necessary) NOTE: The TN750C Announc ement c irc uit p ac k stores announc ements in nonvolatile memory; saving the announc ements to a flashc ard is op tional. 1. If the PPN c ontains a TN750/B Announc ement c irc uit p ac k, typ e display announcements and p ress En te r. 2. If administered...
Page 164
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Upgrading R6csi/R7csi to R8csi 3-8 Upgrade to Release 8 3 3. Insert the Release 8 g eneric p rog ram c ard (orang e c ard) into the TN798B. 4. Power up the c ab inet. The system automatic ally load s the Release 8 software. Upgrade Software NOTE: If you installed the TN798B, skip this step . 1. Insert the Release 8 g eneric p rog ram c ard (orang e c ard) into the...
Page 165
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Upgrading R6csi/R7csi to R8csi 3-9 Upgrade to Release 8 3 Administer the System 1. Log in as craft at the login: p rompt. 2. Check for the Translation Corruption Detected message before p roc eed ing with the up g rad e. If c orruption is d etec ted , refer to ‘‘Translation Corruption Detected’’ in Chapter 5, ‘‘Troubleshooting an Upgrade’’ to c orrec t the p rob lem....
Page 166
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Upgrading R6csi/R7csi to R8csi 3-10 Upgrade to Release 8 3 2. Type the appropriate start and stop information in the Change Day , Month , Date , Time , and Increment (for example, 1:00 eq uals one hour) field s for eac h rule. NOTE: You c an c hang e any rule exc ep t rule 0 (zero). You c annot delete a d aylig ht saving s rule if it is in use on either the Loc ations or...
Page 167
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Upgrading R6csi/R7csi to R8csi 3-11 Upgrade to Release 8 3 4. The c ursor is p ositioned on the Month: field . Typ e the c urrent month in Eng lish (January throug h Dec emb er). See Table 3-4 for Eng lish month names. After the month is entered, p ress Ta b to move to next field 5. The c ursor is p ositioned on the Day of the Month: field . Typ e the d ay of month (1...
Page 168
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Upgrading R6csi/R7csi to R8csi 3-12 Upgrade to Release 8 3 2. Notify the switc h ad ministrator that for any p revious log in names and p assword s that still exist, the p assword s exp ire in 24 hours. When changed, the new login names and passwords must conform to the following req uirements: As b efore, a log in name must have 3 to 6 alp hanumeric c harac ters. A p...
Page 169
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Upgrading R6csi/R7csi to R8csi 3-13 Upgrade to Release 8 3 Enable Customer Options and Alarm Origination 1. Get the DOSS order number of the upgrade from the project manager and ask the reg ional Customer Software Ad ministration to c omp lete the step s in the shad ed b ox. See ‘‘Where to Call for Tec hnic al Sup p ort’’ on p ag e -xix for telep hone numb ers. NOTE: As p...
Page 170
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Upgrading R6csi/R7csi to R8csi 3-14 DEFINITY AUDIX Power Procedures 3 Return Equipment 1. Return rep lac ed eq uip ment to Luc ent Tec hnolog ies ac c ord ing to the req uirements outlined in: BCS/Material Log istic s, MSL/Attend ed Stoc king Loc ations Method s and Proc ed ures for Basic Material Returns 2. Retain the old translation c ard for up to 10 b usiness days...