Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 211

DEFINITY ECS Release 8.2 Installation, Upgrades, 
and Additions for Compact Modular Cabinets  555-233-118  Issue 1
April 2000
Adding or Removing Hardware 
4-39 Add IP Interface Assembly 
4
3. Type iptrunk
 in the Password
 field  and  c lic k OK
. 
4. After log g ing  on for the first time, c hang e the ad ministrator p assword and , 
if d esired , the user name, to ensure sec urity. See your Wind ows NT server 
d oc umentation for d etails.
A-Law versus Mu-Law
For systems using  A-Law c omp and ing , an...

Page 212

DEFINITY ECS Release 8.2 Installation, Upgrades, 
and Additions for Compact Modular Cabinets  555-233-118  Issue 1
April 2000
Adding or Removing Hardware 
4-40 Add IP Interface Assembly 
4
4. Typ e the new d omain name in the Domain
 field and  c lic k OK > OK > 
Close
.
5. When p romp ted  to reb oot the c omp uter, selec t one of the following  
op tions:
nNo
 if you have not assig ned  IP ad dresses then g o to ‘‘Assign an IP 
Address’’
nYe s
 if you have assigned  IP ad dresses. 
Assign an IP...

Page 213

DEFINITY ECS Release 8.2 Installation, Upgrades, 
and Additions for Compact Modular Cabinets  555-233-118  Issue 1
April 2000
Adding or Removing Hardware 
4-41 Add IP Interface Assembly 
4
!CAUTION:
Do not c hange any setting s on the ad ap ter lab eled  [ 1]  for any 
reason.
6. Selec t the DEC Ethernet ad ap ter lab eled  [ 2] .
7. Typ e a valid  IP ad d ress for the IP Interfac e server in the IP Address:
 
field .
8. Typ e the ap p rop riate sub net mask in the Subnet Mask:
 field. 
NOTE:
Not all...

Page 214

DEFINITY ECS Release 8.2 Installation, Upgrades, 
and Additions for Compact Modular Cabinets  555-233-118  Issue 1
April 2000
Adding or Removing Hardware 
4-42 Add IP Interface Assembly 
4
11. Typ e d omain name in the Domain
 field .
12. If using  DNS, c lic k 
Add  under the DNS Service Search Order
 field  and 
type its IP ad d ress.
13. Clic k on the WINS Ad dress tab . 

Page 215

DEFINITY ECS Release 8.2 Installation, Upgrades, 
and Additions for Compact Modular Cabinets  555-233-118  Issue 1
April 2000
Adding or Removing Hardware 
4-43 Add IP Interface Assembly 
4
14. Make sure the [ 2]  DEC shows in the Adapter
 field.
15. If WINS server is availab le, typ e its IP ad d ress in the Primary WINS 
Server
 field .
16. If DNS is availab le, selec t Enable DNS for Windows Resolution
.
17. If the network uses an imp orted LMHOSTS file, selec t Enable LMHOSTS 
Lookup 
and Import...

Page 216

DEFINITY ECS Release 8.2 Installation, Upgrades, 
and Additions for Compact Modular Cabinets  555-233-118  Issue 1
April 2000
Adding or Removing Hardware 
4-44 Add IP Interface Assembly 
4
If administered  remotely throug h p c ANYWHERE:
21. Clic k on the p c ANYWHERE Restart Host Comp uter b utton on the toolb ar 
to restart the c omputer.
If administered  loc ally on a monitor, keyb oard, and  mouse:
21. Clic k Ye s
 in the d ialog  b ox to restart the c omp uter. 
!WARNING:
When c onnec ted  remotely...

Page 217

DEFINITY ECS Release 8.2 Installation, Upgrades, 
and Additions for Compact Modular Cabinets  555-233-118  Issue 1
April 2000
Adding or Removing Hardware 
4-45 Add IP Interface Assembly 
4
3. At the c ommand p romp t, type ping nnn.nnn.nnn.nnn (whic h is the IP 
ad d ress of your g ateway). 
nIf everything  is c onfigured  c orrec tly, the system respond s with the 
following message:
Reply from nnn.nnn.nnn.nnn: bytes=32 time Settings > Control Panel > 
Network
. Selec t the Adapters
 tab  and  hig...

Page 218

DEFINITY ECS Release 8.2 Installation, Upgrades, 
and Additions for Compact Modular Cabinets  555-233-118  Issue 1
April 2000
Adding or Removing Hardware 
4-46 Add IP Interface Assembly 
4
3. At the c ommand  p romp t, typ e ping 192.11.13.8 (whic h is the IP ad d ress of 
the internal p roc essor). 
nIf you have c onnec tivity, the system respond s with the following  
messag e:
Reply from 192.11.13.8: bytes=32 time

Page 219

DEFINITY ECS Release 8.2 Installation, Upgrades, 
and Additions for Compact Modular Cabinets  555-233-118  Issue 1
April 2000
Adding or Removing Hardware 
4-47 Add IP Interface Assembly 
4
3. Attach the mouse to the MOUSE connector of the external c able 
assemb ly.
4. Plug  the monitor into an AC p ower rec ep tac le and  turn it on.
5. If upg rad ing  loc ally, reb oot Wind ows NT b y p ressing  the rec essed  reset 
b utton on the fac ep late (see Figure 4-9
) of the TN802B IP Interfac e until 
the...

Page 220

DEFINITY ECS Release 8.2 Installation, Upgrades, 
and Additions for Compact Modular Cabinets  555-233-118  Issue 1
April 2000
Adding or Removing Hardware 
4-48 Add IP Interface Assembly 
4
5. When d one, c lic k OK, OK
.
Upgrade to TN802B (R8)
NOTE:
The upg rad e takes ab out 20 minutes.
1. Insert the flash d isk into the rig ht most slot on the TN802 IP trunk. On the 
monitor, a d ialog  b ox assig ns a d rive letter with the removab le med ia 
d esig nation; the d efault is D:. 
2. Rig ht c lic k on...