Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 111
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-85 CAMA/E911 Installation 1 Screen 1-11. Class of Restriction form (page 1) 36. On the Class of Restric tion sc reen (pag e 1), in the Calling Party Restriction: field , typ e none and p ress En te r. 37. Typ e Save Translation and press En te r. Page 1 of 3 CLASS OF RESTRICTION COR Number: 10 COR...
Page 112
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-86 Install the BRI Terminating Resistor 1 Install the BRI Terminating Resistor The resistors balanc e the c able p lant b etween the rec eiver and the transmitter on the interfac e. When using the TN2198 ISDN-BRI 2-Wire U Interfac e c irc uit p ac k, an NT1 is req uired. A terminating resistor is always req uired near the terminal when...
Page 113
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-87 Install the BRI Terminating Resistor 1 Terminating Resistor Adapter Figure 1-38 shows an 8-p in 440A4 terminating resistor ad ap ter. The ad ap ter has an 8-wid e plug at 1 end , a short c ord , and an 8-wid e jac k at the op p osite end . Figure 1-38. 8-Wide Terminating Resistor Adapter (440A4) Figure Notes 1. 8-wid e p lug 2. 8-wid...
Page 114
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-88 Install the BRI Terminating Resistor 1 Closet Mounted (110RA1-12) The 110RA1-12 terminating resistor bloc k c onsists of twelve 2-p air c irc uits and p rovid es the 100 Ohm termination used for ISDN-BRI c irc uits. Figure 1-39 shows the wiring of the 110RA1-12. Three rows of 110D-4 c onnec tor b loc ks c ontain resistors and c ap...
Page 115
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-89 Install the BRI Terminating Resistor 1 Figure 1-40 shows the wiring c onnec tions for the 110RA1-12 terminal b loc k. The TN556 BRI switc h p ort is terminated to b ottom row C. Figure 1-40. Typical Installation of Terminating Resistor Block For p oint-to-p oint wiring , the top row c onnec ts to the b lue station field . The p air c...
Page 116
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-90 Install Multi-point Adapters 1 Install Multi-point Adapters Use multi-point ad ap ters to p rovid e sig nal fanout of the T-interfac e. BR851-B or the 367A p erform fanout at the work station. These ad ap ters sup p ort more than 1 ISDN terminal p er horizontal 4-p air D-insid e wire (DIW). To sup p ort multiple horizontal runs, a MDF...
Page 117
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-91 Install Multi-point Adapters 1 367A Adapter The 367A ad ap ter p rovid es fanout for up to 7 terminals. See Figure 1-42. Figure 1-42. Wiring Diagram of 367A Adapter Figure Notes 1. Jac k 1 2. Jac k 23. Jac k 8 4. 367A ad ap ter 312 88 877 766 655 544 433 322 211 1 4
Page 118
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-92 Install Multi-point Adapters 1 Basic Multi-point Installation Distances Figure 1-43 p rovid es c ab ling information for fanout of ISDN-BRI multi-point installations. In Figure 1-43 , the terminating resistor is loc ated in the satellite c loset. All d istanc es assume 24 AWG (#5) (0.26 mm2) D-Insid e Wire (DIW). Figure 1-43. Basic...
Page 119
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-93 Install Off-Premises Station Wiring 1 Install Off-Premises Station Wiring The c abling for off-p remises stations is p rovid ed by the loc al telep hone c omp any. These stations c an ap p ear on any of the RJ21X network interfac es p rovid ed for the CO trunks. !CAUTION: Use only an FCC-ap p roved (or eq uivalent) analog type...
Page 120
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-94 Install Off-Premises Station Wiring 1 Figure 1-44. Connections for 1 to 8 Out-of-Building Analog Telephones Figure Notes 1. Loc ally eng ineered c ab les 2. Out-of-b uild ing wiring 3. Multi-p air p rotec tor units (p rimary p rotec tors with heat c oils or eq uivalent with sneak current protection) 4. 356A ad ap ter 5. B25A c ab le...