Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 101
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-75 Install and Wire Telephones and Other Equipment 1 Install Attendant Console — Optional 1. Position the attend ant c onsole in the d esired loc ation and c onnec t the mod ular c ord to the information outlet. 2. Install lab els p er the Attend ant Console form and Disp lay Mod ule form assig nments. 3. Install a Digital Line c irc...
Page 102
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-76 Connect External Alarms and Auxiliary Connections 1 Connect External Alarms and Auxiliary Connections NOTE: The AUX c onnec tor is p art of the Proc essor Interfac e c ab le assemb ly (J1). Alarm Input Alarms c an b e g enerated on ad junc t eq uip ment, sent to the DEFINITY System, and rec ord ed and rep orted as “ external...
Page 103
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-77 Telephone Pin Designations 1 Emergency Transfer and Auxiliary Power NOTE: Only 1 emerg enc y transfer p ower p anel and 1 auxiliary power c onnec tion is provided per system. Connec t emerg enc y transfer p ower and auxiliary p ower as shown in Table 1-16 . Auxiliary p ower inc ludes power to an attend ant c onsole or ad junc t devic...
Page 104
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-78 CAMA/E911 Installation 1 CAMA/E911 Installation Configuration The CAMA/E911 feature will only work on R8 CMC if TN429C CO trunk c irc uit p ac ks (or later suffix) are used . Port Networks (PNs) that inc lud e TN429C c irc uit pac ks used to interfac e to CAMA trunks may require some CPTR resourc es to b e either TN744D V2 or TN2182B...
Page 105
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-79 CAMA/E911 Installation 1 5. In the Outgoing Display: field , enter y . 6. In the CESID I Digits Sent: field , enter the number d irec ted b y the Central Offic e (CO) or the Pub lic Safety Answering Point (PSAP). 7. Sc roll to p ag e 3 of the form. Screen 1-4. Administrable Timers form (page 3) 8. On the Administrable Timers sc reen...
Page 106
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-80 CAMA/E911 Installation 1 10. At the promp t, type change feature-access-code and press En t e r. Screen 1-6. Feature Access Code (FAC) form (page 1) 11. The Feature Ac c ess Cod e (FAC) sc reen (p ag e 1) ap p ears. 12. In the Auto Route Selection (ARS) Access Code 1: field, ad minister the ARS ac c ess c od e (in the examp le above,...
Page 107
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-81 CAMA/E911 Installation 1 Screen 1-7. ARS Digit Analysis Table 14. On ARS Dig it Analysis Tab le sc reen app ears. In the Dialed String field , in the first emp ty row, enter 11 . 15. In the Total Mn field , enter 2 . 16. In the Total Mx field , enter 2 . 17. In the Rte Pat field , enter the d esired Route Pattern (in the examp le...
Page 108
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-82 CAMA/E911 Installation 1 24. At the p rompt, typ e change route-pattern (the route pattern to b e c hanged ; in the examp le b elow, the route pattern is 11) and p ress En te r. Screen 1-8. Route Pattern form (Page 1) 25. On the Route Pattern sc reen, in Grp. No . field , enter the CAMA trunk g roup number. 26. In the FRL field ,...
Page 109
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-83 CAMA/E911 Installation 1 28. At the p rompt, typ e change route-pattern (the route pattern to b e c hanged ; in the examp le b elow, the route pattern is 12) and p ress En te r. Screen 1-9. Route Pattern form (Page 1) 29. On the Route Pattern sc reen, in Grp. No . field , typ e the CAMA trunk g roup number and p ress En te r. 30....
Page 110
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-84 CAMA/E911 Installation 1 Screen 1-10. CAMA Numbering Format form 33. In the CAMA Numb ering - E911 Format sc reen (p ag e 1), in System CESID Default: field , enter your own system d efault and p ress En t e r. This is the numb er outp ulsed when the extension c od e is not found in the CAMA Numb ering tab le. See Screen 1-10 ....