Here you can view all the pages of manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation, Upgrades, And Additions For Compact Modular Cabinets Manual. The Lucent Technologies manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 121
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-95 Install Off-Premises Station Wiring 1 Figure 1-45 shows the c onnec tions for up to 24 off-p remises analog telep hones. Conc entrations of analog line p airs are used at b oth b uild ing s to minimize the off-p remises wiring req uired . At the MDF, jump ers must b e c onnec ted b etween 1 row/c onnec ting b loc k in the white...
Page 122
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-96 Install Off-Premises Station Wiring 1 Circuit Protectors Carb on b loc k, or eq uivalent p rotec tion is req uired at both b uilding entranc es. Also sneak c urrent p rotec tion is req uired . Protec tion c an b e provid ed b y a 4-typ e p rotec tor or a 3-typ e p rotec tor p lus a sep arate sneak c urrent p rotec tor. The 4-typ e p...
Page 123
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-97 Install Off-Premises Station Wiring 1 Digital Out-of-Building Telephones Protec tion is req uired at b oth b uild ing entranc es for d ig ital out-of-b uilding voic e terminals. There are 2 different typ es of protec tors that c an b e used to p rotec t d ig ital voic e terminals and d ig ital line c irc uit p ac ks. The 2 p rotec...
Page 124
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-98 Install Emergency Transfer Unit and Associated Telephones 1 The maximum rang e for out-of-b uild ing dig ital voic e terminals is 3400 feet (1036 m) when using 24 AWG (#5) (0.26 mm2) wire and 2200 feet (670 m) when using 26 AWG (#4) (0.14 mm2) wire. The rang e c an extend to 5000 feet (1524 m) using 24 AWG (#5) (0.26 mm2) wire or...
Page 125
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-99 Install Emergency Transfer Unit and Associated Telephones 1 Install the Emergency Transfer Panel The 808A Emerg enc y Transfer Panel is used in the following installation examp le. 1. Install the transfer p anel on any mounting frame in either a vertic al or horizontal p osition. The housing has ears for sc rew-mounting and c utouts...
Page 126
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-100 Install Emergency Transfer Unit and Associated Telephones 1 3. Loc ate the c irc uit start selec tion switc hes. See Figure 1-46. These are the first 10 two-p osition switc hes on the left sid e of the 808A. The switc hes set eac h of the 5 inc oming trunk lines to either loop start or g round start. Two switc hes are used for eac...
Page 127
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-101 Install Emergency Transfer Unit and Associated Telephones 1 8. Chec k the system for normal op eration as follows: a. Plac e the test switc h (switc h 12) in NORMAL OPERATION. b. Ensure the power supply is providing -48 VDC at 80 mA maximum. The p ower LED should b e ON. c . Chec k wiring c onnec tions. d . Verify there is d ial tone...
Page 128
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-102 Install Emergency Transfer Unit and Associated Telephones 1 38 BK-G TTC4 Tip -PBX Trunk Circuit 4 13 G-BK RTC4 Ring-PBX Trunk Circuit 4 39 BK-BR TTK4 Tip -CO Trunk Circ uit 4 14 BR-BK RTK4 Ring-CO Trunk Circ uit 4 40 BK-S TLC4 Tip -PBX Line Port 4 15 S-BK RLC4 Ring-PBX Line Port 4 41 Y-BL TST4 Tip -Emerg enc y Terminal 4 16 BL-Y RST4...
Page 129
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-103 Install Emergency Transfer Unit and Associated Telephones 1 9. Chec k the system for emergenc y transfer op eration as follows: a. Plac e the test switc h (switc h 12) in the ACTIVATED p osition. b . The p ower LED should b e OFF. c . Verify there is d ial tone on all emerg enc y transfer sets. 10. Connec t the 808A to the MDF with a...
Page 130
DEFINITY ECS Release 8.2 Installation, Upgrades, and Additions for Compact Modular Cabinets 555-233-118 Issue 1 April 2000 Installing and Cabling the Cabinets 1-104 Install Emergency Transfer Unit and Associated Telephones 1 Figure 1-48 shows the c onnec tions at the trunk/auxiliary field for a telep hone used for emerg enc y transfer and as a normal extension. Figure 1-48. Connections for Telephone Used for Emergency Transfer and as Normal Extension Figure Notes 1. To network interfac e fac...