    Have a look at the manual Lucent Technologies Definity Application Notes For Type Approval Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 484
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    63 Bolivia 
                                                                                                                                                                    
                                                                     Page   2 of 10
    TRUNK FEATURES
              ACA Assignment? n                 Measured: none
                                                                 Maintenance Tests? y
                                        Data Restriction? n
       Abandoned Call Search? n
       Suppress # Outpulsing? n
                                                                     Page   3 of 10
                                         TRUNK GROUP
    ADMINISTRABLE TIMERS
       Incoming Disconnect(msec): 500             Outgoing Disconnect(msec): 500
                                                  Outgoing Dial Guard(msec): 1600
      Incoming Glare Guard(msec): 1500           Outgoing Glare Guard(msec): 1500
     
           Ringing Monitor(msec): 5200               Incoming Seizure(msec): 500
       Outgoing End of Dial(sec): 10         Outgoing Seizure Response(sec): 5
     Programmed Dial Pause(msec): 1500
              Flash Length(msec): 540
    END TO END SIGNALING
        Tone(msec): 350                          Pause(msec): 150
    OUTPULSING INFORMATION
        PPS: 10    Make(msec): 40   Break(msec): 60      PPM? n
                                                                     Page   4 of 10
                                         TRUNK GROUP
                                          Administered Members (min/max):   0/0
                                              Total Administered Members:   0
    GROUP MEMBER ASSIGNMENTS
    Port     Code     Sfx   Name        Night        Mode       Type        Ans Delay
    1: 
    2: 
    3:  
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    64 Bolivia 
    DIOD Trunk Group Administration
                                                                     Page   1 of 10
                                        TRUNK GROUP
    Group Number:                     Group Type: diod           CDR Reports: y
      Group Name: OUTSIDE CALL               COR: 1         TN: 1        TAC:GG
       Direction: two-way       Outgoing Display? n
     Dial Access? n               Busy Threshold: 99
    Queue Length: 0        Country: 1
                                       Auth Code? n    Digit Absorption List:
        Prefix-1? n                  Trunk Flash? n          Toll Restricted? n
    TRUNK PARAMETERS
                Trunk Type: immed-start
        Outgoing Dial Type: mf                            Incoming Dial Type: mf       
         Trunk Termination: rc
           Digit Treatment:                                           Digits:
           Expected Digits:                                Sig Bit Inversion: none
         Terminal Balanced? n                                  RA Trunk Loss: 0db
                                       Trunk Gain: high       Drop Treatment: silence
    Disconnect Supervision - In? y  Out? n
     Answer Supervision Timeout: 10               Receive Answer Supervision? n
                                                                    Page   2 of 20
    TRUNK FEATURES
              ACA Assignment? n    Measured: none
                                                            Maintenance Tests? y
                           Data Restriction? n
       Suppress # Outpulsing? n 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    65 Bolivia 
                                                                     Page   3 of 10
                                         TRUNK GROUP
    ADMINISTRABLE TIMERS 
       Incoming Disconnect(msec): 500               Outgoing Disconnect(msec): 500
       Incoming Dial Guard(msec): 70                Outgoing Dial Guard(msec): 1600
      Incoming Glare Guard(msec): 1500             Outgoing Glare Guard(msec): 1500
     
           Ringing Monitor(msec): 5200                 Incoming Seizure(msec): 500
       Outgoing End of Dial(sec): 10           Outgoing Seizure Response(sec): 5
     Programmed Dial Pause(msec): 1500
              Flash Length(msec):         Incoming Incomplete Dial Alarm(sec): 255
    END TO END SIGNALING
        Tone(msec): 350              Pause(msec): 150 
    OUTPULSING INFORMATION
         PPS: 10    Make(msec): 40   Break(msec): 60      PPM? n
                                                                   Page   4 of 10
                                         TRUNK GROUP
                                          Administered Members (min/max):   0/0
    GROUP MEMBER ASSIGNMENTS                  Total Administered Members:   0
    Port     Code     Sfx    Name        Night       Mode       Type       Ans Delay
    1: 
    2: 
    3:  
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    66 Bolivia 
    DID Trunk Group Administration
                                                                    Page   1 of 10
                                       TRUNK GROUP
    Group Number:                     Group Type: did            CDR Reports: y
      Group Name: OUTSIDE CALL               COR: 1        TN: 1         TAC:
                                Country: 1
                                       Auth Code? n
    TRUNK PARAMETERS
                Trunk Type: immed-start         Incoming Rotary Timeout(sec): 5
        Incoming Dial Type: tone
         Trunk Termination: rc                       Disconnect Timing(msec): 500
           Digit Treatment:                                           Digits:
           Expected Digits:                                Sig Bit Inversion: none
         Terminal Balanced? n                                  RA Trunk Loss: 0db
       Extended Loop Range? n          Trunk Gain: high       Drop Treatment: silence
     Disconnect Supervision - In? y
                                                                     Page   2 of 10
    TRUNK FEATURES
              ACA Assignment? n      Measured: none
                                                             Maintenance Tests? y
                             Data Restriction? n
       Suppress # Outpulsing? n
                                                                     Page   3 of 10
                                        TRUNK GROUP
    ADMINISTRABLE TIMERS
       Incoming Disconnect(msec): 500
       Incoming Dial Guard(msec): 70
              Flash Length(msec): 540      Incoming Incomplete Dial Alarm(sec): 255
    END TO END SIGNALING
        Tone(msec): 350      Pause(msec): 150 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    67 Bolivia 
    DS1 for CO, DID and DIOD Trunks to the PTT 
    Using Digital Trunks
                                                                     Page   4 of 10
                                        TRUNK GROUP
                                          Administered Members (min/max):   0/0
    GROUP MEMBER ASSIGNMENTS                  Total Administered Members:   0
    Port        Code         Sfx        Name
    1: 
    2: 
    3: 
                                                                    Page   1 of  1
                                     DS1 CIRCUIT PACK
                Location:                               Name: E-1CO, DID, DIOD
                Bit Rate: 2.048                  Line Coding: hdb3
          Signaling Mode: CAS
            Interconnect: CO                Country Protocol: 7
    Interface Companding: alaw                           CRC? n
               Idle Code: 11111111
     MAINTENANCE PARAMETERS
          Slip Detection? n                Near-end CSU Type: other 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    68 Brazil 
    Brazil
    Ta b l e  1 9 shows the rec ommended  c irc uit p ac ks.
    Table 19. Recommended and Available CPs in Brazil
    Equipment Equipment Type
    Cab inet Typ e & Power GAC-MCC AC-MCC DC-MCC AC-SCC 
    DC-SCC AC-CSCC AC-CMC
    AC Power Voltag e & Freq 127V/60Hz 220V/60Hz 
    Ring  Generator 25Hz 
    Tone Detec tor > TN2182B > TN744D TN748D
    Tone Cloc k > TN2182B TN780 
    R2MFC Circ uit > TN744D TN744B
    Sp eec h Synthesizer > TN725B 
    Call Classifier > TN744D
    Announc ement > TN750C TN750B 
    Analog DID Trunk > TN753
    Analog  CO Trunk (No PPM) 
    Analog  CO Trunk (w/PPM) > TN465C TN465B
    4 Wire Tie Trunk > TN2140B 
    2 Wire Tie Trunk > TN439
    Auxiliary Trunk > TN763D 
    Dig ital CO/DID Trunk > TN464F TN464E TN464D TN464C
    Dig ital Tie Trunk > TN464F TN464E TN464D TN464C
    Dig ital PRI CO Trunk > TN464F TN464E TN464D TN464C
    Dig ital BRI Trunk
    Dig ital Converter PRI-DASS   
    Dig ital Converter PRI-DPNSS
    Dig ital Converter PRI-BRI   
    8 Port Analog  Line n/a
    16 Port Analog  Line > TN746B
    24 Port Analog  Line n/a
    Continued on next page 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    69 Brazil 
    Country-Specific Feature
    When not using the Bloc k Collec t Call feature, the Country field  should  b e 16
    .
    NOTE:
    Bloc k Collec t Call req uires TN753 v22 or later for DID trunks, TN464F v9 or 
    later for DS1 trunks, and  TN465C (all vintag es) for analog  CO trunks.
    NOTE:
    The 900 ohms feature requires TN465CV2 or later for analog  CO c irc uit 
    p ac ks, and  either TN2155V3 or later or TN2183BV4 or later for analog  line 
    circuit packs.
    Feature Administration
    The sc reen d isp lays shown in this sec tion were effec tive the d ate the typ e 
    ap p roval was award ed . The sc reens may have c hang ed  sinc e that d ate.
    Only those feature-related  p arameters that may have a Typ e Ap p roval or b asic  
    c onnec tivity imp lic ation for a p artic ular c ountry are listed  here.
    nARS/AAR Ad ministration 
    To enab le ARS administration, on the System-Parameters 
    Customer-Op tions sc reen, set the ARS
     field  to y
    . You also should check all 
    ARS/AAR d efaults. All d efault ARS analysis c odes are deleted  b efore 
    d ialed  strings are ad d ed for routing when DEFINITY is installed  outsid e of 
    North Americ a. Be aware that the d efault for the 10 d ig its c ause dialing 
    p rob lems. In p artic ular, the following  c all typ es (ap pear as ARS/AAR 
    d efaults) typ ic ally are not used  in non-North Americ an ARS/AAR tab les: 4 Wire Digital Line > TN754B 
    2 Wire Digital Line #TN2224 > TN2181
    Data Line > TN726B 
    BRI-U Line TN2198
    BRI-ST Line TN556B
    Ta b l e  1 9 .Recommended and Available CPs in Brazil — Continued
    Equipment Equipment Type
    Continued on next page 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    70 Brazil 
    Luc ent rec ommend s only the following  c all typ es b e used  outside North 
    Americ a:
    System Parameter Administration
    Feature-Related System Parameters
    fnp a: North Americ an numb ers with an area c od e.
    hnp a: North Americ an numb ers without an area c od e.
    svc : North Americ an numb ers of the screen ‘‘x11’’.
    int: For all international numbers.
    natl: For all national PN numb ers.
    pubu: For all other external (that is, not extensions) numbers.
                                                                     Page   1 of  6
                            FEATURE-RELATED SYSTEM PARAMETERS
                                    Trunk-to-Trunk Transfer: all
       Coverage - Subsequent Redirection No Answer Interval: 2
              Coverage - Caller Response Interval (seconds): 4
                            Keep Held SBA at Coverage Point? y
    Automatic Callback - No Answer Timeout Interval (rings): 3
                       Call Park Timeout Interval (minutes): 10
        Off-Premises Tone Detect Timeout Interval (seconds): 20
                                 AAR/ARS Dial Tone Required? y
                                         Music/Tone on Hold: none
              Music (or Silence) on Transferred Trunk Calls? no
                           DID/Tie/ISDN Intercept Treatment: attd
     Internal Automatic Answer for Attendant Extended Calls? n
                  Automatic Circuit Assurance (ACA) Enabled? n 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    71 Brazil 
                                                                    Page   2 of  6
                                FEATURE-RELATED SYSTEM PARAMETERS
    LEAVE WORD CALLING PARAMETERS
      Maximum Number of Messages Per Station (when MSA not in service):10
      Stations with System-wide Retrieval Permission (enter extension)
      1:          2:          3:          4:          5:
      6:          7:          8:          9:         10:
      WARNING!    SEE USER DOCUMENTATION BEFORE CHANGING TTI STATE 
                    Terminal Translation Initialization (TTI) Enabled? n
           External Coverage Treatment for Transferred Incoming Calls? n
    SECURITY VIOLATION NOTIFICATION (SVN) PARAMETERS HAVE MOVED TO
    THE SYSTEM-PARAMETERS SECURITY SCREEN
                                                                     Page   3 of  6
                             FEATURE-RELATED SYSTEM PARAMETERS
                         Reserved Slots for Attendant Priority Queue: 5
                                          Time before Off-hook Alert: 10
                              Emergency Access Redirection Extension: 
                                      Service Observing Warning Tone? y
                Number of Emergency Calls Allowed in Attendant Queue: 5
                                                Call Pickup Alerting? n
                   Deluxe Paging and Call Park Timeout to Originator? n
          Controlled Outward Restriction Intercept Treatment: tone
         Controlled Termination Restriction (Do Not Disturb): tone
                   Controlled Station to Station Restriction: tone
    AUTHORIZATION CODE PARAMETERS        Authorization Codes Enabled?
                                           Authorization Code Length:
                              Authorization Code Cancellation Symbol: #
                                             Attendant Time Out Flag? n
                                          Display Authorization Code? y 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    72 Brazil 
                                                                     Page   4 of  6
                              FEATURE-RELATED SYSTEM PARAMETERS
    SYSTEM PRINTER PARAMETERS
                 System Printer Extension:                      Lines Per Page: 60
    SYSTEM-WIDE PARAMETERS
                              Switch Name:
    CALL CENTER SYSTEM PARAMETERS
      Direct Agent Announcement Extension:
                                               Direct Agent Announcement Delay: 
                                               Converse Delay  Data1: 0  Data2: 2
       Direct Agent Announcement Extension:        Converse Pulse ON: 100  OFF: 70
                                                      Prompting Timeout (secs): 10
    CALL MANAGEMENT SYSTEM PARAMETERS
            BCMS/VuStats Measurement Interval: hour
    BCMS/VuStats Abandon Call Timer (seconds):              Validate Login IDs? n
              ACD Login Identification Length:             Adjunct CMS Release:
    MALICIOUS CALL TRACE PARAMETERS
                   Apply MCT Warning Tone? n    MCT Voice Recorder Trunk Group:
                                                                     Page   5 of  6
                               FEATURE-RELATED SYSTEM PARAMETERS
            Public Network Trunks on Conference Call: 5          Auto Start? n
       Conference Parties with Public Network Trunks: 6           Auto Hold? n
    Conference Parties without Public Network Trunks: 6      Attendant Tone? y
            Night Service Disconnect Timer (seconds): 180     Bridging Tone? n
                    Short Interdigit Timer (seconds): 3     Conference Tone? n
                 Unanswered DID Call Timer (seconds):        Intrusion Tone? n
                 Line Intercept Tone Timer (seconds): 30
                                  DID Busy Treatment: tone
                  Allow AAR/ARS Access from DID/DIOD? n
      DISTINCTIVE AUDIBLE ALERTING
                           Internal: 1   External: 2   Priority: 3
                                     Attendant Originated Calls: external 
    						