Have a look at the manual Lucent Technologies Definity Application Notes For Type Approval Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 383 Slovak Republic Slovak Republic Ta b l e 5 2 shows the rec ommended c irc uit p ac ks. Table 52. Recommended and Available CPs in Slovak Republic Equipment Equipment Type Cab inet Typ e & Power GAC-MCC DC-MCC AC-SCC DC-SCC AC-CSCC AC-CMC AC Power Voltag e & Freq 220V/50Hz Ring Generator 25Hz Tone Detec tor > TN2182B > TN744D TN420C Tone Cloc k > TN2182B TN780 R2MFC Circ uit Sp eec h Synthesizer > TN457 Call Classifier > TN744D Announc ement TN750C TN750B Analog DID Trunk > TN753v17 Analog CO Trunk (No PPM) > TN747Bv12 Analog CO Trunk (w/PPM) #TN465C> TN465B 4 Wire Tie Trunk > TN760Dv11 2 Wire Tie Trunk Auxiliary Trunk > TN763D Dig ital CO/DID Trunk > TN464F TN464E Dig ital Tie Trunk > TN464F TN464E Dig ital PRI CO Trunk n/a Dig ital BRI Trunk > TN2185 Dig ital Converter PRI-DASS Dig ital Converter PRI-DPNSS Dig ital Converter PRI-BRI 8 Port Analog Line n/a 16 Port Analog Line > TN746B 24 Port Analog Line n/a Continued on next page
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 384 Slovak Republic Feature Administration The sc reen d isp lays shown in this sec tion were effec tive the d ate the typ e ap p roval was award ed . The sc reens may have c hang ed sinc e that d ate. Only those feature-related p arameters that may have a Typ e Ap p roval or b asic c onnec tivity imp lic ation for a p artic ular c ountry are listed here. nARS/AAR Ad ministration To enab le ARS administration, on the System-Parameters Customer-Op tions sc reen, set the ARS field to y . You also should check all ARS/AAR d efaults. All d efault ARS analysis c odes are deleted b efore d ialed strings are ad d ed for routing when DEFINITY is installed outsid e of North Americ a. Be aware that the d efault for the 10 d ig its c ause dialing p rob lems. In p artic ular, the following c all typ es (ap pear as ARS/AAR d efaults) typ ic ally are not used in non-North Americ an ARS/AAR tab les: Luc ent rec ommend s only the following c all typ es b e used outside North Americ a: 4 Wire Digital Line > TN754B 2 Wire Digital Line #TN2224 > TN2181 TN2136 Data Line > TN726B BRI-U Line BRI-ST Line fnp a: North Americ an numb ers with an area c od e. hnp a: North Americ an numb ers without an area c od e. svc : North Americ an numb ers of the screen ‘‘x11’’. int: For all international numbers. natl: For all national PN numb ers. pubu: For all other external (that is, not extensions) numbers. Table 52. Recommended and Available CPs in Slovak Republic — Continued Equipment Equipment Type Continued on next page
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 385 Slovak Republic System Parameter Administration Only those feature-related p arameters that may have a Typ e Ap p roval or b asic c onnec tivity imp lic ation for a p artic ular c ountry are listed here. nFeature-Related System Parameters Ad ministration — Off-Premises Tone Detec t Timeout Interval (sec ond s): 5 — Nig ht Servic e Disc onnec t Timer (sec ond s): 10 (10 or b lank for testing op tional responses to errors — Unanswered DID Call Timer (sec ond s): 180 — DID Busy Treatment (set to attendant for testing op tional resp onse to errors) display system-parameters features Page 1 of 6 FEATURE-RELATED SYSTEM PARAMETERS Trunk-to-Trunk Transfer: all Coverage Subsequent Redirection/CFWD No Answer Interval: 2 Coverage - Caller Response Interval (seconds): 4 Keep Held SBA at Coverage Point? y Automatic Callback - No Answer Timeout Interval (rings): 3 Call Park Timeout Interval (minutes): 10 Off-Premises Tone Detect Timeout Interval (seconds): 5 AAR/ARS Dial Tone Required? y Music/Tone on Hold: none Music (or Silence) on Transferred Trunk Calls? no DID/Tie/ISDN Intercept Treatment: attd Messaging Service Adjunct (MSA) Connected? n Internal Automatic Answer for Attendant Extended Calls? n Automatic Circuit Assurance (ACA) Enabled? n Abbreviated Dial Programming by Assigned Lists? n Auto Abbreviated/Delayed Transition Interval (rings): 2
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 386 Slovak Republic — Outp ulse Without Tone? n (for d ial tone d etec tion) — Network Feed b ac k During Tone Detec tion? n (for dial tone detection) nSystem Parameters Customer Op tions — ARS? y (for d ial tone d etec tion) display system-parameters features Page 5 of 6 FEATURE-RELATED SYSTEM PARAMETERS Public Network Trunks on Conference Call: 5 Conference Parties with Public Network Trunks: 6 Conference Parties without Public Network Trunks: 6 Night Service Disconnect Timer (seconds): 10 Short Interdigit Timer (seconds): 3 Unanswered DID Call Timer (seconds): 180 Line Intercept Tone Timer (seconds): 20 Auto Start? n Auto Hold? y Attendant Tone? y Bridging Tone? n Conference Tone? n Intrusion Tone? y DID Busy Treatment: tone Allow AAR/ARS Access from DID/DIOD? n DISTINCTIVE AUDIBLE ALERTING Internal: 1 External: 2 Priority: 3 display system-parameters features FEATURE-RELATED SYSTEM PARAMETERS Pull Transfer: n Level Of Tone Detection: precise Wait Answer Supervision Timer? n Repetitive Call Waiting Tone? n Outpulse Without Tone? n Network Feedback During Tone Detection? n Intercept Treatment On Failed Trunk Transfers? n Vector Disconnect Timer (min): Station Tone Forward Disconnect: intercept Misoperation Alerting? n Allow Conference via Flash? y RECALL TIMING Flashhook Interval? y Upper Bound (msec): 1000 Lower Bound (msec): 200 Forward Disconnect Timer (msec): 600 ENHANCED DCS Enhanced DCS Enabled? n
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 387 Slovak Republic — Malic ious Call Trac e? y (for Malic ious Call feature) — Multifreq uenc y Sig naling ? y nSystem Parameter Country Op tions Ad ministration — Comp and ing Mode: A-Law — Dig ital Loss Plan: 14 — Analog Ring ing Cad enc e: 14 — Analog Line Transmission: 14 display system-parameters customer-options Page 1 of 2 OPTIONAL FEATURES G3 Version: V4 Logged-In ACD Agents: 150 Abbreviated Dialing Enhanced List? n Call Work Codes? n A/D Grp/Sys List Dialing Start at 01? n CAS Branch? n ACD? n CAS Main? n AT&T Adjunct Links? n DCS (Basic)? n Answer Supervision by Call Classifier? n DCS Call Coverage? n ARS? y DTMF Feedback Signals For VRU? n ARS/AAR Partitioning? y Emergency Access to Attendant? y ASAI Interface? n Expert Agent Selection (EAS)? n ATMS? n External Device Alarm Admin? n Audible Message Waiting? n Flexible Billing? n Authorization Codes? n Forced Entry of Account Codes? n BCMS (Basic)? n Hospitality (Basic)? y BCMS/VuStats LoginIDs? n G3V3 Hospitality Enhancements? n BCMS/VuStats Service Level? n Hospitality Parameter Reduction? n display system-parameters customer-options OPTIONAL FEATURES ISDN-PRI? n Service Observing (VDNs)? n ISDN-PRI over PACCON? n Station and Trunk MSP? n Lookahead Interflow (LAI)? n Tenant Partitioning? n Malicious Call Trace? y Terminal Trans. Init. (TTI)? n Multifrequency Signaling? y Time of Day Routing? n Multiple Call Handling (On Request)? n Uniform Dialing Plan? n Multiple Call Handling (Forced)? n Vectoring (Basic)? n PASTE (Display PBX Data on Phone)? n Vectoring (Prompting)? n Vectoring (G3V4 Enhanced)? n Premier Business Package? y Vectoring (ANI/II-Digits Routing)? n Processor and System MSP? n Vectoring (G3V4 Advanced Routing)? n Private Networking? n VDN of Origin Announcement? n VDN Return Destination? n Restrict Call Forward Off Net? y Voice Mail Application Support? n Secondary Data Module? n VuStats? n Service Observing (Basic)? y VuStats (G3V4 Enhanced)? n Service Observing (Remote/By FAC)? n Wideband Switching? n
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 388 Slovak Republic — Tone Detec tion Mod e: 5 — Customized Individual Tones In this sec tion, c ustomized tone d efinitions follow the data-entry syntax as sp ec ified for entry on the Ind ivid ual Tone Ad ministration Sc reen: [ (Freq uenc y/Level)|silenc e|g oto)] [ (Duration ms)|(Step)] — Intrusion: n(425/-11.0)(350) n(silenc e)(350) n(425/-5.0)(350) n(silenc e)(1500) n(goto)(1) — Reord er (Cong estion): n(425/-5)(150) n(silenc e)(150) n(goto)(1) — Sec ond ary Dial Tone: n(425/-5)(150) n(silenc e)(150) n(425/-5)(150) n(silenc e)(150) n(425/-5)(150) n(silenc e)(150) n(425/-5)(650) display system-parameters country-options Page 1 of 21 SYSTEM PARAMETERS COUNTRY-OPTIONS Companding Mode: A-Law Base Tone Generator Set: 14 440Hz PBX-dial Tone? n 440Hz Secondary-dial Tone? n Digital Loss Plan: 14 Analog Ringing Cadence: 14 Set Layer 1 timer T1 to 30 seconds? n Analog Line Transmission: 14 TONE DETECTION PARAMETERS Tone Detection Mode: 5 Dial Tone Validation Timer(msec): 500 Interdigit Pause: long
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 389 Slovak Republic n(silenc e)(650) n(goto)(1) —PBX Dial Tone: n(425/-5)(500) n(goto)(1) —Busy: n(425/-5)(350) n(silenc e)(350) n(goto)(1) — Ringback: n(425/-5)(1000) n(silenc e)(4000) n(goto)(1) — Call Wait 1: n(425/-11)(350) — Rec all Dial: n(425/-4)(150) n(silenc e)(150) n(425/-4)(150) n(silenc e)(150) n(425/-4)(1000) n(goto)(5) nC D R Sys t e m Pa r a m e t e r s — Primary Outp ut Format: int-d irec t (for showing PPM)
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 390 Slovak Republic nSystem Parameter Multifreq uenc y Sig naling Ad ministration (Pay c lose attention to the values on the following three sc reens. They are c ritic al.) — Req uest Inc oming ANI (non-AAR/ARS)? n (To c hec k Inc oming ANI, enter yes. It is p art of the malic ious c all trac e op tion.) NOTE: On Pag e 2 of the Multifreq uenc y-Sig naling -Related System Parameters sc reen, Group -I, numb ers 12, 13, and 14, should all b e ani-not-avail. display system-parameters cdr CDR SYSTEM PARAMETERS Node Number (Local PBX ID): 1 CDR Date Format: month/day Primary Output Format: int-direct Primary Output Ext: eia Secondary Output Format: Use ISDN Layouts? n EIA Device Bit Rate: 9600 Use Enhanced Formats? n Record Outgoing Calls Only? n Intra-switch CDR? n Suppress CDR for Ineffective Call Attempts? y CDR Call Splitting? y Disconnect Information in Place of FRL? n Attendant Call Recording? y Interworking Feat-flag? n Force Entry of Acct Code for Calls Marked on Toll Analysis Form? n Calls to Hunt Group - Record: member-ext Record Called Vector Directory Number Instead of Group or Member? n Record Non-Call-Assoc TSC? n Record Call-Assoc TSC? n Digits to Record for Outgoing Calls: dialed Privacy - Digits to Hide: 0 CDR Account Code Length: 2 display system-parameters multifrequency-signaling Page 1 of 3 MULTIFREQUENCY-SIGNALING-RELATED SYSTEM PARAMETERS Incoming Call Type: group-ii-mfc Outgoing Call Type: group-ii-mfc Maintenance Call Type: none Test Call Extension: Interdigit Timer (sec): 20 Outgoing Forward Signal Present Timer (sec): 20 Outgoing Forward Signal Absent Timer (sec): 12 Multifrequency Signaling Incoming Intercept Treatment? y Received Signal Gain(-Loss) (dB): 0 Transmitted Signal Gain(-Loss) (dB): -3 ANI Prefix: 42 Collect All Digits Before Seizure? n ANI for PBX: 400 Next ANI Digit: send-ani Request Incoming ANI (non-AAR/ARS)? n Called Party Category: user-type Use COR for Calling Party Category? n
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 391 Slovak Republic nARS Digit Analysis — Rte Pat: 2 (for d ial tone d etec t) display system-parameters multifrequency-signaling Page 2 of 3 MULTIFREQUENCY-SIGNALING-RELATED SYSTEM PARAMETERS INCOMING FORWARD SIGNAL TYPES INCOMING BACKWARD SIGNAL TYPES (Tones from CO) (Tones to CO) Group-I Group-II Group-A Group-B 11: send-congest 1: normal 1 : next-digit 3 : busy 12: send-congest 2: busy-rt-attd 3 : end-of-dial 4 : congestion 13: ani-not-avail 3: busy-rt-attd 4 : congestion 5 : intercept 14: send-congest 4: normal 5 : send-ani 6 : free 15: end-of-dial 5: busy-rt-attd : : 6: normal : : 7: normal : : 8: normal : : 9: busy-rt-attd : : 10: normal : : 11: send-intercept : : 12: send-intercept : : 13: normal : : 14: normal : : 15: send-intercept : : display system-parameters multifrequency-signaling MULTIFREQUENCY-SIGNALING-RELATED SYSTEM PARAMETERS OUTGOING FORWARD SIGNAL TYPES OUTGOING BACKWARD SIGNAL TYPES (Tones to CO) (Tones from CO) Group-I Group-II Group-A Group-B 12: ani-not-avail 1 : normal 1: next-digit 1: free 15: end-of-digits 1 : attendant 2: last-digit 2: congestion : 6 : data-call 3: end-of-dial 3: busy : : 4: congestion 4: congestion : : 5: send-ani 5: intercept : 6: setup-sppath 6: free : 7: last-2-digits 7: free : 8: last-3-digits 8: intercept : 9: congestion 9: congestion : 10: congestion 10: congestion : 11: congestion 11: congestion : 12: congestion 12: congestion : 13: congestion 13: congestion : 14: congestion 14: congestion : 15: congestion 15: congestion
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 392 Slovak Republic nRoute Pattern — Inserted Digits: + (for d ial tone d etec t) nConsole Parameters display ars analysis 0 ARS DIGIT ANALYSIS TABLE Partitioned Group Number: 1 Percent Full: 2 Dialed Total Rte Call Nd ANI Dialed Total Rte Call Nd ANI String Mn Mx Pat Type Num Rq String Mn Mx Pat Type Num Rq 2 2 7 2 pubu n n 3 2 7 2 pubu n n 4 2 7 2 pubu n n 5 2 7 2 pubu n n 6 7 7 2 hnpa n n 7 2 7 2 pubu n n 8 2 7 2 pubu n n 9 2 7 2 pubu n n n n n n n n n n n n n n display route-pattern 2 Pattern Number: 2 Grp. FRL NPA Pfx Hop Toll No. Del Inserted No. Mrk Lmt List Digits Digits 1: 29 0 + 2: 3: 4: 5: 6: