Home
>
Lucent Technologies
>
Communications System
>
Lucent Technologies Definity Application Notes For Type Approval Manual
Lucent Technologies Definity Application Notes For Type Approval Manual
Have a look at the manual Lucent Technologies Definity Application Notes For Type Approval Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 323 Netherlands — RA Trunk Loss: 0d B —Trunk Gain: high — Rec eive Answer Sup ervision: no — Answer Sup ervision Timeout: 10 (This sets b oth the CP firmware timer and software timer. Set to 0 for any trunk that will rec eive answer sup ervision.) — Disc onnec t Sup ervision: nno for signaling type A nyes for signaling type B1 — Sup p ress # outp ulsing : Yes nTi m i n g Set the following timers from the Administrab le Timers sc reen d uring ad ministration of eac h trunk g roup . Selec t the following CO trunk timer values for this c ountry: — Inc oming Disc onnec t: 500 ms. (not ap p lic ab le - ac c ep t d efault) — Outg oing Disc onnec t: 500 ms. (not ap p lic ab le - ac c ep t d efault) — Outg oing Dial Guard : 1600 ms — Inc oming Glare Guard : 1500 ms — Outg oing Glare Guard : 1500 ms — Outg oing Rotary Dial Interd igit: 800 ms. — Outgoing Dial Pulse Rate (PPS): 10 pps. — Outg oing Rotary Dig it Dial Make: 40 ms. — Outg oing Rotary Dig it Dial Break: 60 ms. — Ring Monitor Timer: 5200 ms. — Inc oming Seizure: 200 ms. — Outg oing End -of-Dial: 10 sec . — Outg oing Seizure Resp onse: 5 (not need ed in Netherland s - b ut works and is useful - d rop s trunk, g ives reord er if no resp onse from far end ) — Prog rammed Dial Pause: 1500 msec . — Disc onnec t Sig nal Error: 240 sec . This field d oes not app ear for all trunk typ es. — End -To-End Sig naling Tone: 350 ms (ac c ep t d efault). — End -To-End Sig naling Pause: 150 ms (ac c ep t d efault). — PPM : N o
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 324 Netherlands DID Trunks nTrunk Group Sc reen — Group Typ e: DID — Country: 5 —Trunk Gain: high — Inc oming Dial Typ e: rotary or tone as negotiated with serving central office. — Trunk Type: immed -start — Trunk Termination: rc (c omp lex Z). — Disc onnec t Sup ervision: Yes — Disc onnec t Timing : 500 msec (This field will not b e used with CPs that c an ac c ep t the Inc oming Disc onnec t and Outg oing Disc onnec t timers. Set these latter two timers from the Ad ministrab le Timers Sc reen.) — Dig it Treatment: b lank —Digits: blank — Exp ec ted Dig its: d ep end s on system size and numb ering p lan — Terminal Balanc ed : no (should b e no for all c ountries) — RA Trunk Loss: 0d B — Extend ed Loop Rang e: (Used Only with TN459) no — Interc ept Tone: no — Inc oming Rotary Timeout (sec ): 5 sec (This field will not b e used with CPs that c an ac c ep t the Incoming Partial Dial WCC timer. This timer will b e set from the Ad ministrable Timers Sc reen.) nTi m i n g Set the following timers from the Administrab le Timers sc reen d uring ad ministration of eac h trunk g roup . Selec t the following DID trunk timer values for this c ountry: — Inc oming Disc onnec t: 500 ms. — Inc oming Dial Guard : 70 ms. (set to minimum to g et minimum start dial delay) — Inc oming Partial Dial: 18 sec . Does not ap p ear for Tone sig naling type. — Flash Leng th: 100 ms. — Inc oming Inc omplete Dial: 255 sec .
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 325 Netherlands Tie Trunks Information regard ing Typ e Ap proval-related setting s c urrently is not availab le. Digital Trunks The following are the most c ommon valid ad ministrab le c omb inations. They are c omp atib le with p ub lic -network and Typ e Ap p roval stand ard s for eac h c ountry. CO Trunks nDS1 Ad ministration Sc reen15 — Circ uit Pac k: TN464D (not entered as an ad ministrab le item) — Bit Rate: 2.048 (must matc h p lug on c irc uit p ac k) — Cab le imp ed anc e (p lug on c irc uit p ac k): 75 *W — Interfac e Comp anding : A-law — Line Cod ing: HDB3 — Sig naling Mod e: CAS — Country Protoc ol: 5 (Netherland s) — Interc onnec t: CO —CRC?: No — Id le Cod e: 01010100 — Slip Detec tion: Y Trunk Group Parameters Dig ital trunk p arameter values should b e set as for analog CO trunks, with the following exc ep tion: nPPM? ye s nFreq uenc y: 50Hz/12kHz DID Trunks nDS1 Ad ministration Sc reen — Circ uit Pac k: TN464D (not entered as an ad ministrab le item) — Bit Rate: 2.048 — Cab le imp ed anc e (p lug on c irc uit p ac k): 75 *(W — Interfac e Comp anding : A-law — Line Cod ing: HDB3 15. DS 1 is also analog ous to the term E1 whic h has b een c oined for the Europ ean T1 or 2 mb it interface.
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 326 Netherlands — Sig naling Mod e: CAS — Country Protoc ol: 5 (Netherland s) — Interc onnec t: CO —CRC?: No — Id le Cod e: 01010100 Trunk Group Parameters Dig ital trunk p arameter values should b e set as for analog DID trunks. Tie Trunks Non-ISDN Signaling Example nDS1-Ad ministration Sc reen — Circ uit Pac k: TN464D (not entered as an ad ministrab le item) — Bit Rate: 2.048 — Cab le imp ed anc e (p lug on c irc uit p ac k): 75 *(W — Interfac e Comp anding : A-law — Line Cod ing: HDB3 — Sig naling Mod e: CAS — Country Protoc ol: 5 (Netherland s) — Interc onnec t: p b x —CRC?: no — Id le Cod e: 01010100 ISDN PRI (Private Network) Signaling This examp le assumes use of US Option 1 with fac ility assoc iated sig naling . Other feature op tions will req uire c hang es in one or more ad ministered items. nDS1 Ad ministration sc reen — Circ uit Pac k: TN464D (not entered as an ad ministrab le item) — Bit Rate: 2.048 — Cab le imp ed anc e (p lug on c irc uit p ac k): 75 — Interfac e Comp anding : A-law — Line Cod ing: HDB3 — Sig naling Mod e: isd n-p ri — Country Protoc ol: 1 (US) — Connec t: p b x
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 327 Netherlands — Interfac e: user —CRC: No — Id le Cod e: 01010100 nSignaling Group screen — Assoc iated Sig naling : Yes — Primary D_Channel: xxxx16 (xxxx= > dep end s on CP p hysic al loc ation) nTrunk Group Ad ministration sc reen — Group Type: isdn-pri — Service Type: public_ntwrk ISDN PRI (Public Network) — Circ uit Pac k: TN464D (not entered as an ad ministrab le item) — Bit Rate: 2.048 — Cab le imp ed anc e (p lug on c irc uit p ac k): 75 — Interfac e Comp anding : A-law — Line Cod ing: HDB3 — Sig naling Mod e: isd n-p ri — Country Protoc ol: 5 (Netherland s) — Connec t: Network —CRC: No — Id le Cod e: 01010100 nSignaling Group screen — Assoc iated Sig naling : Yes — Primary D_Channel: xxxx16 (xxxx= > dep end s on CP p hysic al loc ation) nTrunk Group Ad ministration sc reen — Group Type: isdn-pri — Service Type: public_ntwrk
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 328 New Zealand New Zealand Ta b l e 4 4 shows the rec ommended c irc uit p ac ks. Table 44. Recommended and Available CPs in New Zealand Equipment Equipment Type Cab inet Typ e & Power GAC-MCC DC-MCC AC-SCC DC-SCC AC-CSCC AC-CMC AC Power Voltag e & Freq 240V/50Hz Ring Generator 20Hz Tone Detec tor > TN2182B > TN744D Tone Cloc k > TN2182B TN780 R2MFC Circ uit n/a Sp eec h Synthesizer > TN457 Call Classifier > TN744D Announc ement TN750C TN750B Analog DID Trunk > TN436B TN436 Analog CO Trunk (No PPM) TN2147C TN2147 Analog CO Trunk (w/PPM) #TN465C > TN438B 4 Wire Tie Trunk > TN437B TN437 2 Wire Tie Trunk TN439 Auxiliary Trunk > TN763D TN417 Dig ital CO/DID Trunk > TN2464 Dig ital Tie Trunk > TN2464 Dig ital PRI CO Trunk TN2464 Dig ital BRI Trunk > TN2185 Dig ital Converter PRI-DASS n/a Dig ital Converter PRI-DPNSS TN-CCSC-2 Dig ital Converter PRI-BRI n/a 8 Port Analog Line TN2183 16 Port Analog Line TN2215 #TN2183 24 Port Analog Line TN2793 Continued on next page
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 329 New Zealand 4 Wire Digital Line > TN754B TN413 2 Wire Digital Line #TN2214 > TN2181 Data Line > TN726B BRI-U Line BRI-ST Line TN556B Table 44. Recommended and Available CPs in New Zealand Equipment Equipment Type Continued on next page
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 330 Panama Panama Ta b l e 4 5 shows the rec ommended c irc uit p ac ks. Table 45. Recommended and Available CPs in Panama Equipment Equipment Type Cab inet Typ e & Power GAC-MCC AC-MCC DC-MCC AC-SCC DC-SCC AC-CSCC AC-CMC AC Power Voltag e & Freq 120V/60Hz 208V/60Hz 240V/60Hz Ring Generator 20Hz Tone Detec tor > TN2182 > TN744C TN748D TN748C Tone Cloc k > TN2182 TN780 TN768 R2MFC Circ uit n/a Sp eec h Synthesizer > TN725B Call Classifier > TN2182B, > TN2182 > TN744D > TN744C TN744B Announc ement #TN750C > TN750B TN750 Analog DID Trunk > TN753 Analog CO Trunk (No PPM) > TN747B Analog CO Trunk (w/PPM) n/a 4 Wire Tie Trunk > TN760D 2 Wire Tie Trunk n/a Auxiliary Trunk > TN763D TN763C TN763B Dig ital CO/DID Trunk > TN464F TN464E TN464D TN767 Dig ital Tie Trunk > TN464F TN464E TN464D TN767 TN722B Dig ital PRI CO Trunk > TN464F TN464E TN464D TN767 Dig ital BRI Trunk Dig ital Converter PRI-DASS Dig ital Converter PRI-DPNSS Dig ital Converter PRI-BRI 8 Port Analog Line TN742 16 Port Analog Line > TN746B TN746 Continued on next page
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 331 Panama Feature Administration The sc reen d isp lays shown in this sec tion were effec tive the d ate the typ e ap p roval was award ed . The sc reens may have c hang ed sinc e that d ate. Only those feature-related p arameters that may have a Typ e Ap p roval or b asic c onnec tivity imp lic ation for a p artic ular c ountry are listed here. nARS/AAR Ad ministration To enab le ARS administration, on the System-Parameters Customer-Op tions sc reen, set the ARS field to y . You also should check all ARS/AAR d efaults. All d efault ARS analysis c odes are deleted b efore d ialed strings are ad d ed for routing when DEFINITY is installed outsid e of North Americ a. Be aware that the d efault for the 10 d ig its c ause dialing p rob lems. In p artic ular, the following c all typ es (ap pear as ARS/AAR d efaults) typ ic ally are not used in non-North Americ an ARS/AAR tab les: Luc ent rec ommend s only the following c all typ es b e used outside North Americ a: 24 Port Analog Line n/a 4 Wire Digital Line > TN754B 2 Wire Digital Line > TN2224 TN2181 Data Line > TN726B BRI-U Line TN2198 BRI-ST Line TN556B fnp a: North Americ an numb ers with an area c od e. hnp a: North Americ an numb ers without an area c od e. svc : North Americ an numb ers of the screen ‘‘x11’’. int: For all international numb ers. natl: For all national PN numb ers. p ub u: For all other external (that is, not extensions) numb ers. Ta b l e 4 5 .Recommended and Available CPs in Panama — Continued Equipment Equipment Type Continued on next page
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 332 Panama Feature-Related System Parameters Page 1 of 6 FEATURE-RELATED SYSTEM PARAMETERS Trunk-to-Trunk Transfer: all Coverage - Subsequent Redirection No Answer Interval: 2 Coverage - Caller Response Interval (seconds): 4 Keep Held SBA at Coverage Point? y Automatic Callback - No Answer Timeout Interval (rings): 3 Call Park Timeout Interval (minutes): 10 Off-Premises Tone Detect Timeout Interval (seconds): 20 AAR/ARS Dial Tone Required? y Music/Tone on Hold: none Music (or Silence) on Transferred Trunk Calls? no DID/Tie/ISDN Intercept Treatment: attd Internal Automatic Answer for Attendant Extended Calls? n Automatic Circuit Assurance (ACA) Enabled? n Page 2 of 6 FEATURE-RELATED SYSTEM PARAMETERS LEAVE WORD CALLING PARAMETERS Maximum Number of Messages Per Station (when MSA not in service):10 Stations with System-wide Retrieval Permission (enter extension) 1: 2: 3: 4: 5: 6: 7: 8: 9: 10: WARNING! SEE USER DOCUMENTATION BEFORE CHANGING TTI STATE Terminal Translation Initialization (TTI) Enabled? n External Coverage Treatment for Transferred Incoming Calls? n SECURITY VIOLATION NOTIFICATION (SVN) PARAMETERS HAVE MOVED TO THE SYSTEM-PARAMETERS SECURITY SCREEN