Have a look at the manual Lucent Technologies Definity Application Notes For Type Approval Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 273 Italy (Lucent Technologies) NOTE: If c onnec ted to a 20-p ps system, then set the Outgoing Rotary Dig it Dial Make and Outg oing Rotary Dig it Dial Break times to 20 and 30 ms resp ec tively. nOutg oing Rotary Dig it Dial Break: 60 ms nOutg oing Rotary Dial Interd igit: 700 ms nInc oming Seizure: 100 ms (E&M c ont) nOutg oing End -of-Dial: 10 sec nOutg oing Seizure Resp onse: 1 sec (E&M c ont, d is) nDisc onnec t Sig nal Error: 2 sec (E&M c ont) nDisc onnec t Sig nal Error: 1 sec (E&M dis) nInc oming Partial Dial: 15 sec Digital Trunk Administration This sec tion d oes not list all p ossible valid ad ministrab le c omb inations.Rather the most c ommon or stand ard c omb ination, c omp atib le with p ub lic -network and Typ e Ap proval stand ard s for eac h c ountry, is p resented : nCO Trunks — DS1 Ad ministration Sc reen nCirc uit Pac k: TN464F (Not entered as ad ministrab le item) nBit Rate: 2.048 nInterfac e Comp anding : A-law nLine Cod ing: HDB3 nSignaling Mode: CAS nCountry Protoc ol: 4 nInterc onnec t: CO nCRC?: Yes nId le Cod e: 01010100 nTrunk Group Ad ministration sc reen (Timing ) nDig ital trunk timing values should b e set as for analog CO trunks. nDID Trunks — DS1 Ad ministration sc reen nCirc uit Pac k: TN464F nBit Rate: 2.048
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 274 Italy (Lucent Technologies) nInterfac e Comp anding : A-law nLine Cod ing: HDB3 nSignaling Mode: CAS nCountry Protoc ol: 4 nInterc onnec t: CO nCRC?: No nId le Cod e: 01010100 — Trunk Group Ad ministration sc reen (Timing ) Dig ital trunk timing values should b e set as for analog DID trunks. nTi e Tru n k s — Non-ISDN Sig naling Examp le (DS1 Ad ministration sc reen) nGroup Typ e: tie nCirc uit Pac k: TN464F nBit Rate: 2.048 nInterfac e Comp anding : A-law nLine Cod ing: HDB3 nSignaling Mode: CAS nCountry Protoc ol: 4 nInterc onnec t: p b x nCRC?: no nId le Cod e: 01010101 — Trunk Group Ad ministration sc reen (Timing ) Set the following timers from the Administrab le Timers sc reen d uring ad ministration of eac h trunk g roup . Selec t the following Tie trunk timer values for this c ountry: nInc oming Disc onnec t: 50 ms nOutg oing Disc onnec t: 50 ms nInc oming Dial Guard : 70 ms nOutg oing Dial Guard : 1000 ms nInc oming Glare Guard : 200 ms nOutg oing Glare Guard : 200 ms nOutg oing Dial Pulse Rate (PPS): 10 p p s nOutg oing Rotary Dig it Dial Make: 50 ms nOutg oing Rotary Dig it Dial Break: 50 ms
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 275 Italy (Lucent Technologies) nOutg oing Rotary Dial Interd igit: 700 ms nInc oming Seizure: 100 ms nOutg oing Seizure Resp onse: 60 sec nDisc onnec t Sig nal Error: 255 sec nInc oming Partial Dial: 6 sec — ISDN-PRI (Private Network) Sig naling (DS1 Ad ministration sc reen) This examp le assumes use of US Op tion 1 with fac ility assoc iated sig naling . Other feature op tions will req uire c hang es in one or more ad ministered items. nCirc uit Pac k: TN464F nBit Rate: 2.048 nInterfac e Comp anding : A-law nLine Cod ing: HDB3 nSignaling Mode: isdn-pri nCountry Protoc ol: 4 nConnec t: p b x nInterfac e: user nCRC: No nId le Cod e: 01010101 nSignaling Group screen nAssoc iated Sig naling : Yes nPrimary D_Channel: xxxx16 (xxxx= > dep end s on CP p hysical location) — Trunk Group Ad ministration sc reen nGroup Type: isdn-pri nServic e Type: tie nISDN-PRI (Public Network) (DS1 Ad ministration sc reen) Temporary Sig naling Connec tions and D-Channel Bac kup features must not b e ad ministered for E1 interfac es that use country protocol 13 (Italy). nCirc uit Pac k: TN464F nBit Rate: 2.048 nInterfac e Comp anding : A-law nLine Cod ing: HDB3 nSignaling Mode: isdn-pri
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 276 Italy (Lucent Technologies) nConnec t: Network nCountry Protocol: 13 nProtoc ol Version: a, for 1TR6 and b , for E-DSS1. Protoc ol version selec tion d ep end s on the typ e of p ub lic network servic e p urc hased by the c ustomer nCRC: yes nId le Cod e: 01010100 nSignaling Group screen nAssoc iated Sig naling : Yes nPrimary D_Channel: xxxx16 (xxxx= > dep end s on CP p hysical location) — Trunk Group Ad ministration sc reen nGroup Type: isdn-pri nCOR: COR for isd n-p ri p ub lic _ntwrk trunks must have a higher FRL than all Tie Trunks nService Type: public_ntwrk nOverlap Rec eiving: yes, a must for DID trunk op eration Station Administration The ad ministrator c an selec t italian on station ad ministration and attend ant ad ministration to pic k Italian as the d isp lay lang uage for the c orresp ond ing d isp lay set user. n85XX Terminals The 8510 terminal must b e ad ministered as a 7507 terminal to b e ab le to use the 8510 terminal for b oth voic e and d ata operation. If used for voic e only op eration, a terminal typ e of 8510D is suffic ient. Aliasing a terminal type of 8510+ to a 7507 is p referab le. — Terminal Setting s: Eac h 8510 must b e p rogramed with the following p arameters: nCountry Code = 6 nComp and ing Mode = a-law nTransmit Value = + 3 nReceive Value = -5 nSid e Tone Value = 0 nUse the following p rog ramming seq uenc e. n8510 Prog ram Instruc tions: (items in b rac kets [ ] mean use that b utton) for setting the p rop er c ountry c od e of 6.
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 277 Italy (Lucent Technologies) En t e r : Value Meaning ______ ______ [ MENU] [ MUTE] 2 p rog ram for 4 setting c ountry op tion 6 c ountry c ode 6 # save value For setting the p rop er transmission values for Italy (G3V3):
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 278 Italy (Lucent Technologies) En t e r : Value Meaning ______ ______ [ MENU] [MUTE] 2 p rog ram for 5 setting transmission values 2 a-law # save value and p roc eed to next step 3 transmit value of + 3 d esired * tog g le to selec t + # save value and p roc eed to next step 5 rec eive value of -5 d esired * tog g le to selec t - # save value and p roc eed to next step 0 sid e tone value of 0 d esired # save value and c omp lete setup step s for b oth voic e and d ata op eration The following values have been determined as a result of type approval. n84XX (94XX) Terminals Aliasing the terminal typ es of 9403B to 8403B, 9410B to 8410B, 9410D to 8410D, and 9434D to 8434D is a preferable way of hand ling the ad ministration for the 94XX family of terminals. —Terminal Parameters nDefault Parameter Set: 4 nCustomize Parameters? n The default p arameters for selec ting Italy c ountry c od e 4 are as follows and ARE PROGRAMMED AUTOMATICALLY. These values are inc lud ed as referenc e information only. — Display Mode: 1 — DLI Voltag e Level: auto — Handset Exp and er Enab led ? n
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 279 Italy (Lucent Technologies) — Primary Levels: nVoic e Transmit (d B): + 14.0 nVoic e Sid etone (d B): -25.0 nVoice Receive (dB): -5.0 nTouc h Tone Sid etone (d B): -25.0 nTouc h Tone Transmit (d B): -4.0 — Ad junc t Levels nVoic e Transmit (d B): 0.0 nVoice Receive (dB): -2.0 nVoic e Sid etone (d B): -14.5 nTouc h Tone Sid etone (d B): -25.0 n603/302B Terminals (nothing exc ep t for alias of 94XX to 84XX eq uivalent) —Terminal Parameters nDefault Parameter Set: 4 nCustomize Parameters? n The default p arameters for selec ting Italy c ountry c od e 4 are as follows and ARE PROGRAMMED AUTOMATICALLY with software load G3V3i.02.0.044.0 or later loads. These values are inc lud ed as referenc e information only. — Display Mode: 1 — DLI Voltag e Level: auto — Primary Levels: nVoice Transmit (dB): + 7.0 nVoic e Sid etone (d B): -35.5 nVoice Receive (dB): -6.5 nTouc h Tone Sid etone (d B): -25.0 nTouc h Tone Transmit (d B): -4.0
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 280 Italy-Italtel Italy-Italtel Ta b l e 3 8 shows the rec ommended c irc uit p ac ks. Table 38. Recommended and Available CPs in Italy-Italtel Equipment Equipment Type Cab inet Typ e & Power GAC-MCC DC-MCC AC-SCC AC-CSCC AC-CMC AC Power Voltag e & Freq 220V/50Hz Ring Generator 20Hz Tone Detec tor > TN420C Tone Cloc k > TN780 TN419B R2MFC Circ uit n/a Sp eec h Synthesizer > TN433 Call Classifier > TN2182B > TN744D Announc ement #TN750C > TN750B Analog DID Trunk > TN2139 Analog CO Trunk (No PPM) > n/a Analog CO Trunk (w/PPM) > TN2138 4 Wire Tie Trunk #TN2140B TN2140 2 Wire Tie Trunk > TN497 Auxiliary Trunk > TN763D TN417 Dig ital CO/DID Trunk > TN464F TN464E TN464D TN464C TN464B Dig ital Tie Trunk > TN464F TN464E TN464D TN464C TN464B Dig ital PRI CO Trunk n/a Dig ital BRI Trunk Dig ital Converter PRI-DASS Dig ital Converter PRI-DPNSS Dig ital Converter PRI-BRI 8 Port Analog Line n/a 16 Port Analog Line > TN2183 > TN2135 24 Port Analog Line n/a Continued on next page
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 281 Italy-Italtel Feature Administration The sc reen d isp lays shown in this sec tion were effec tive the d ate the typ e ap p roval was award ed . The sc reens may have c hang ed sinc e that d ate. Only those feature-related p arameters that may have a Typ e Ap p roval or b asic c onnec tivity imp lic ation for a p artic ular c ountry are listed here. nARS/AAR Ad ministration To enab le ARS administration, on the System-Parameters Customer-Op tions sc reen, set the ARS field to y . You also should check all ARS/AAR d efaults. All d efault ARS analysis c odes are deleted b efore d ialed strings are ad d ed for routing when DEFINITY is installed outsid e of North Americ a. Be aware that the d efault for the 10 d ig its c ause dialing p rob lems. In p artic ular, the following c all typ es (ap pear as ARS/AAR d efaults) typ ic ally are not used in non-North Americ an ARS/AAR tab les: Luc ent rec ommend s only the following c all typ es b e used outside North Americ a: 4 Wire Digital Line > TN754B TN413 2 Wire Digital Line > TN2181 TN2136 Data Line > TN726B BRI-U BRI-ST fnp a: North Americ an numb ers with an area c od e. hnp a: North Americ an numb ers without an area c od e. svc : North Americ an numb ers of the sc reen ‘‘x11’’. int: For all international numb ers. natl: For all national PN numbers. p ub u: For all other external (that is, not extensions) numb ers. Ta b l e 3 8 .Recommended and Available CPs in Italy-Italtel — Continued Equipment Equipment Type Continued on next page
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 282 Italy-Italtel System Parameter Administration Only those feature-related p arameters that may have a Typ e Ap p roval or b asic c onnec tivity imp lic ation for a p artic ular c ountry are listed here. nConsole Parameters Ad ministration — Return Call Timeout (sec ): 10 sec nFeature-Related System Parameters Ad ministration — Trunk-to-Trunk Transfer: Permitted b y c ountry’s reg ulations - Selec tion is c ustomer’s c hoic e. — Pub lic Network Trunks on Conferenc e Call: 5 — Conferenc e Parties With PNTs: 6 — Conferenc e Parties Without PNTs: 6 — Line Interc ep t Tone Timer: 30 — Nig ht Servic e Disc onnec t Timer: 180 sec — Short Interd ig it Timer: 3 sec — Unanswered DID Call Timer: 60 —Auto-Hold: Yes 11 — Attend ant Tone: Yes — Bridg ing Tone: No — Conferenc e Tone: No — Intrusion Tone: Yes — Rep etitive Call Waiting Tone: No — DID Busy Treatment: Attend ant — Pull Transfer: No — Level of Tone Detec tion: Prec ise — Outp ulse Without Tone: Yes — (Station-to-Switc h) Rec all Timing : nFlashhook Interval: Yes nUp p er Bound : 1000 ms nLower Bound : 200 ms nCountry Op tions Parameters — Comp and ing Mode: A-law — Base Tone Generation Set: 4 11. Althoug h not a Type App roval issue, this rep resents the convention for this country.