Page 211
Cleaning the Machine 8-24 Note Do not touch the contact indicated in the illustration. 15Press in the magenta toner car- tridge until it locks into place. 16Close the front cover. Downloaded From ManualsPrinter.com Manuals
Page 213
Introduction 9-2 Introduction This chapter provides information to aid you in resolving machine problems you may encounter, or at least guide you to the proper sources for help. Printing a Configuration Page page 9-3 Preventing Media Misfeeds page 9-4 Understanding the Media Path page 9-5 Clearing Media Misfeeds page 9-5 Solving Problems with Media Misfeeds page 9-23 Solving Other Problems page 9-26 Solving Problems with Printing Quality page 9-31 Status, Error, and Service Messages page 9-38...
Page 214
Printing a Configuration Page9-3 Printing a Configuration Page 1 In the main screen, press the + or , key to select REPORT/STATUS, and then press the Select key. 2Press the + or , key to select REPORT, and then press the Select key. 3Press the + or , key to select CONFIGURATION PAGE, and then press the Select key. 4Press the Start-B&W key or the Start-Color key. Downloaded From ManualsPrinter.com Manuals
Page 215
Preventing Media Misfeeds 9-4 Preventing Media Misfeeds Make sure that... Media matches the machine specifications. Media is flat, especially on the leading edge. The machine is on a hard, flat, level surface. You store media in a dry location away from moisture and humidity. You always adjust the media guides in Tray 1 after inserting the media (a guide that is not properly adjusted can cause poor print quality, media mis- feeds, and machine damage). You load the media printing-side up in the tray...
Page 216
Understanding the Media Path9-5 Understanding the Media Path Understanding the media path will help you locate media misfeeds. 1. ADF media feed rollers 2. Document feed tray 3. Document output tray 4. Output tray 5. Imaging cartridge 6. Toner cartridge carousel 7. Tray 1 (multipurpose tray) 8. Tray 2 (optional lower feed unit) 9. Fuser unit 10. Duplex (optional) Clearing Media Misfeeds To avoid damage, always remove misfed media gently, without tearing it. Any piece of media left in the machine,...
Page 217
Clearing Media Misfeeds 9-6 CAUTION Unfused toner can mess your hands, clothes, or anything else it gets on. If you accidentally get toner on your clothes, lightly dust them off as best as you can. If some toner remains on your clothes, use cool, not hot water, to rinse the toner off. If toner gets on your skin, wash it off with cool water and a mild soap. CAUTION If you get toner in your eyes, wash it out immediately with cool water and consult a doctor. If, after clearing the media misfeed, the...
Page 218
Clearing Media Misfeeds9-7 Media Misfeed Messages and Clearing Procedures Media Misfeed Message Page Reference CHECK TRAY1 PAPER LOAD PAPER ( 1xx) (PRESS START KEY) This message appears in the following cases. zWhen no media is loaded in Tray 1 zWhen a misfeed has occurred in Tray 1 With the first case, load media into the tray, and then press the Start key. With the second case, refer to page 9-15. FUSER JAM OPEN TOP COVERpage 9-8 ORIGINAL DOC. JAM OPEN DOC.FEED COVERpage 9-19 OUTPUT JAM OPEN TOP...
Page 219
Clearing Media Misfeeds 9-8 Clearing a Media Misfeed in the Machine 1Open the scanner unit. If there is paper in the output tray, remove it, and then fold up the out- put tray before opening the scanner unit. Note Do not touch the wires and flat cable shown in the illustration. Downloaded From ManualsPrinter.com Manuals
Page 220
Clearing Media Misfeeds9-9 2Grab the handle and lift it up slightly to the back, and then slowly pull the imaging cartridge out vertically. Note Do not touch the PC drum and the transfer belt on the imaging cartridge. Position the removed imaging cartridge horizontally as shown in the illustration at the right. Be sure to keep the imaging cartridge horizontal and place it where it will not become dirty. Do not leave the imaging cartridge removed for more than 15 minutes, and do not place the...