Page 171

Replacing Consumables 7-8
12Remove the cover from the 
toner roller.
Do not touch or scratch 
the toner roller.
13Align the shaft on each end of 
the toner cartridge with its hold-
ers, and then insert the car-
tridge.
Before inserting the toner 
cartridge, make sure that 
the color of the toner car-
tridge to be installed is 
the same as the label on 
the toner cartridge carou-
sel.
Downloaded From ManualsPrinter.com Manuals 

Page 172

Replacing Consumables7-9
Note
Do not touch the contact 
indicated in the illustration.
14Press in the toner cartridge until 
it locks into place.
15Close the front cover.
Downloaded From ManualsPrinter.com Manuals 

Page 173

Replacing Consumables 7-10
16Press the Stop/Reset key to reset the machine and clear the indicator 
message.
The machine must complete a calibration cycle after a toner car-
tridge has been replaced. If you open the scanner unit or front 
cover before the machine is reset, the calibration stops, then starts 
over again after the cover is closed.
Downloaded From ManualsPrinter.com Manuals 

Page 174

Replacing Consumables7-11 Removing All Toner Cartridges
Note
Be careful not to spill toner while removing a toner cartridge. If toner 
spills, immediately wipe it off with a soft, dry cloth.
By selecting the 
EJECT MODE in the PRINTER MODE menu, all toner car-
tridges can be removed.
Follow the procedure described below to use the EJECT MODE.
1With the main screen displayed, press the * key to display the PRINTER 
MODE screen.
2Press the , key to select T/C CHANGE and then press the Select key.
3Press...

Page 175

Replacing Consumables 7-12
5Pull down the handle on the 
toner cartridge until the toner 
cartridge is unlocked and moves 
out slightly toward you.
Remove the toner cartridge.
Do not manually rotate 
the toner cartridge carou-
sel. In addition, do not 
rotate the carousel with 
force, otherwise it may be 
damaged.
Note
Do not touch the contact 
indicated in the illustration.
6Close the front cover.
To exit EJECT MODE, press the Stop/Reset key.
Downloaded From ManualsPrinter.com Manuals 

Page 176

Replacing Consumables7-13
7Follow the same procedure to remove the cartridges for the cyan, black, 
then yellow toners.
8Press the Stop/Reset key to reset the machine.
Replacing the Imaging Cartridge
When replacing an imaging cartridge, refer to the following table. For opti-
mum print quality and performance, use only approved KONICA MINOLTA 
imaging cartridge for your specific machine type, as listed in the table below. 
You can find your machine type and the imaging cartridge part numbers on 
the...

Page 177

Replacing Consumables 7-14
Note
Do not touch the wires and flat 
cable shown in the illustration.
2Grab the handle and lift it up 
slightly to the back, and then 
slowly pull the imaging cartridge 
out vertically.
Note
Dispose of the used imaging cartridge according to your local 
regulations. Do not burn the imaging cartridge.
Downloaded From ManualsPrinter.com Manuals 

Page 178

Replacing Consumables7-15
3Prepare the new imaging cartridge.
Note
Do not touch the PC drum and the transfer belt on the imaging 
cartridge.
4Slowly insert the new imaging 
cartridge vertically, and then 
push it slightly down toward you 
to finish installing the imaging 
cartridge.
5Carefully close the scanner unit.
Downloaded From ManualsPrinter.com Manuals 

Page 179

Replacing Consumables 7-16
Note
Do not touch the wires and flat 
cable shown in the illustration.
The machine must complete a calibration cycle after the imaging 
cartridge has been replaced. If you open the scanner unit or front 
cover before the machine is reset, the calibration stops, then starts 
over again after the cover is closed.
Downloaded From ManualsPrinter.com Manuals 

Page 180

Replacing Consumables7-17 Replacing the Fuser Unit
For optimum print quality and performance, use only approved KONICA 
MINOLTA fuser unit for your specific machine type.
1Turn off the machine and discon-
nect the power cord.
Note
There are extremely hot parts within the machine. Before replacing 
the fuser unit, wait about 20 minutes after turning off the machine, 
and then check that the fusing section has reached room 
temperature, otherwise, you may get burnt.
2Open the scanner unit.
If there is...