Page 21
Description and Installation Atlas AVM JR. Installation and Programming Manual 2-7 10. Program the analog station ports you are using as voicemail ports in the KSU. Refer to APPENDIX E for programming procedures for your particular system as they vary between systems. 11. Program the voicemail ports into a station hunt group. Refer to APPENDIX E for programming procedures for your particular system as they vary between systems. 12. Program the voicemail to ring for incoming calls, either...
Page 22
Description and Installation 2-8 Atlas AVM JR. Installation and Programming Manual 2.3.3.1 Expanding to Four Lines The two-port expansion kit contains: · 2-port expansion card · 4-wire connector · Two plastic stand-offs ä To install the expansion card: 1. Disconnect all external cables and connectors. 2. Remove the 9V DC adapter power plug from the main power supply outlet to turn the AVM JR. off. 3. Open the AVM JR.’s top cover by unscrewing the four screws. 4. Place the two plastic...
Page 23
Description and Installation Atlas AVM JR. Installation and Programming Manual 2-9 · Five hours and twenty minutes card with 4 memory chips ä To install the memory expansion card: 1. Disconnect all external cables and connectors. 2. Remove the 9V DC adapter power plug from the main power supply outlet to turn the AVM JR. off. 3. Open the AVM JR.’s top cover by unscrewing the four screws. 4. Insert the memory card into the SIMM connector. 5. Replace the top panel cover and plug the 9V DC adapter...
Page 24
Description and Installation 2-10 Atlas AVM JR. Installation and Programming Manual 2.4 2.4 Specifications Specifications DC Power Supply 9V DC/800 mA Line Voltage 24V to 72V DC DC Leakage Current < 10 m A On-hook Insulation Resistance between Line Terminal and the Ground 0V to 100V DC > 5 MW 100V to 200V DC > 30 KW 500V AC/50 Hz > 20 KW 100V AC/25 Hz > 100 KW Ring Capacitor 0.47 m F ± 10% On-hook Impedance @ 50V DC, 40V AC/25 Hz > 3000 W Ring Detect 27V to 100V AC/16 to 60 Hz DC...
Page 25
Atlas AVM JR. Installation and Programming Manual 3-1 3. DTMF PROGRAMMING You can program the AVM JR. by: · Telephone using DTMF tones · Computer using the Voicemail Utility Program (see Section 4) This section describes programming the AVM JR. using DTMF tones. Note: You will hear a confirmation tone every time you enter a programming command. 3.1 3.1 Entering and Entering and Exiting the Programming Mode Exiting the Programming Mode The AVM JR. does not handle calls when in the...
Page 26
DTMF Programming 3-2 Atlas AVM JR. Installation and Programming Manual Note: If you exited the programming mode by dialing *900, the AVM JR. plays the opening menu. You can then test the changes made to the system. 3.2 3.2 First Time Programming Checklist First Time Programming Checklist 1. Call from a system extension to the AVM JR.. You will hear the default message (system message 000 - see Appendix C). 2. Dial *900 and the administrator password (default: 1234) to enter the programming...
Page 27
DTMF Programming Atlas AVM JR. Installation and Programming Manual 3-3 Table 3-1 PBX Parameter Commands OPERATION COMMAND DEFAULT Extension Size *300 + X Where X is a digit 1-4 You can only change this parameter if mailboxes and/or legal extensions have not yet been defined. 2 Cut off time for continuous call progress tone detection *301 + X Where X= cut off time in seconds (0-9) 6 seconds Number of rings before the line is answered *310 + X +Y Where X is the port number (1-4) Y is the...
Page 28
DTMF Programming 3-4 Atlas AVM JR. Installation and Programming Manual OPERATION COMMAND DEFAULT Programmable code for retrieving messages *331 + X Where X is a digit 0-9 When the caller dials this digit at the no answer or busy greeting for their mailbox the system will prompt them for their password 9 Disconnect Code *333 + Code1 + # The AVM JR terminates the call when it receives the disconnect code. The code can include up to four digits. Legal values for this code can be any...
Page 29
DTMF Programming Atlas AVM JR. Installation and Programming Manual 3-5 OPERATION COMMAND DEFAULT Day Operator, Night Operator, Fax and Supervisor’s Extension numbers *360 + X + YYYY + # where: X = 1; Day operator X = 2; Night operator X = 3; Fax extension X = 4; Supervisor extension One mailbox can be defined as Supervisor. When the storage memory reaches 80% of its capacity, a message is sent to this mailbox indicating the situation. YYYY = Corresponding extension number 0 0 - -...
Page 30
DTMF Programming 3-6 Atlas AVM JR. Installation and Programming Manual OPERATION COMMAND DEFAULT Busy Signal Cadence Check *375 + XXXX + # Where XXXX is a busy extension number. Checks the busy signal by dialing the busy extension number and playing the busy cadence values. Voice and DTMF Sensitivity *376 + X + Y X = 1; Voice sensitivity level X = 2; DTMF sensitivity level Y = Sensitivity level (0-9) The volume at which the AVM JR detects voice when the called extension answers or the...