Page 121
INTER-TEL PRACTICES GLX-PLUS INSTALLATION & MAINTENANCE TROUBLESHOOTING Issue 2, June 1993 TROUBLESHOOTING CONTENTS PAGE 1. Introduction ......................................................... 2. Troubleshooting Checklist ............................................. 3. Troubleshooting Charts ................................................ A. Features ........................................................ B. Intercom ........................................................ C. CO Lines...
Page 122
TROUBLESHOOTING Issue 2. June 1993 INTER-TEL PRACTICES GLX-PLUS INSTALLATION L MAINTENANCE NOTE: If the LED is not flashing, there may still be an error. Place the PWR switch in the OFF position for 10 seconds; then return it to the ON position. (Turning the PWR switch off drops all calls in progress.) If the LED flashes, a software error has occurred. Follow the procedures given below. a. If the ERROR LED is flashing, an error has occurred in the system. Count the number of flashes...
Page 123
INTER-TEL PRACTICES GLX-PLUS INSTALLATION & MAINTENANCE TROUBLESHOOTING Issue 2, June 1993 3. TROUBLESHOOTING CHARTS 3.1 The simplified troubleshooting charts located on the following pages list symptoms, possible causes, and corrective actions for problems. Look up the problem in the appropriate chart and perform the corrective actions in the order given. The troubleshooting procedures for correcting equipment failures have been divided into the following six categories: A. Features B....
Page 124
TROUBLESHOOTING Issue 2, June 1993 INTER-TEL PRACTICES GLX-PLUS INSTALLATION & MAINTENANCE E. SINGLE-LINE SETS 3.7 If the problem is associated with a single-line set, refer to Figure 6-5, Single-Line Set Troubleshooting Chart, on page 6-14. The troubleshooting charts cover the following features: Single-line set is completely inoperative. Single-line set inoperative; talk battery is present. Single-line set inoperative; calls ring in; talk battery is present. Single-line set receives CO’...
Page 125
INTER-TEL PRACTICES GLX-PLUS INSTALLATION & MAINTENANCE TROUBLESHOOTING Issue 2, June 1993 FIGURE 6-l. FEATURE TROUBLESHOOTING CHART PROBABLE CAUSE User error Defective station instrument Defective Expansion PCB or APM Defective Main Control PCB SYMPTOM Last number redial does not vork Speed-dial memory lost or not working PROBABLE CAUSE User error Dialing speed too fast for PBX or central office Defective keyset Defective Expansion PCB or APM Defective Main Control PCB CORRECTIVE...
Page 126
TROUBLESHOOTING Issue 2, June 1993 INTER-TEL PRACTICES GLX-PLUS INSTALLATION dz MAINTENANCE FIGURE 6-l. FEATURE TROUBLESHOOTING CHART (CONT’D) SYhlPTOM PROBABLE CAUSE Zannot initiate a conference User error Conference circuits are busy Intercom channels are busy Defective station instrument Defective Expansion PCB or CORRECTIVE ACTION I Refer to page 4-30. I There are two conference circuits. When both are busy, the initiating party hears a busy signal. In- side parties are disconnected...
Page 127
INTER-TEL PRACTICES GLX-PLUS INSTALLATION & MAINTENANCE TROUBLESHOOTJNG Issue 2, June 1993 FIGURE 6-l. FEATURE TROUBLESHOOTING CHART (CONT’D) SYMPTOM Call is not forwarded to pub- lic network. Caller hears fast busy signal. PROBABLE CAUSE CORRECTIVE ACTION Call is toll-restricted or line If both station instruments are toll-restricted or is restricted restricted from accessing the CO line, the call is restricted. Line is not programmed for A CO line must be programmed as the call for- call...
Page 128
TROUBLESHOOTING Issue 2, June 1993 INTER-TEL PRACTICES GLX-PLUS INSTALLATION & MAINTENANCE FIGURE 6-2. INTERCOM TROUBLESHOOTING CHART NOTE: These symptoms are isolated to one station instrument only. For identical problems involving more than one station instrument, refer to Figure 6-6, System Troubleshooting Chart, on page 6-16. SYMPTOM No intercom dial tone PROBABLE CAUSE Defective station cabling Defective station instrument Defective Expansion PCB or APM Defective Main Control PCB...
Page 129
INTER-TEL PRACTICES GLX-PLUS INSTALLATION & MAINTENANCE TROUBLESHOOTING Issue 2, June 1993 FIGURE 6-3. CO LINE TROUBLESHOOTING CHART SWJPTOM PROBABLE CAUSE ZO lines will not ring for in- CO ring duration timer is set :oming calls too long CORRECTIVE ACTION Attach a lineman’s test set to one of the lines at the RJ connector. Place an outgoing call that will ring in on the line with the test set. Check for ring sig- nal. If you hear ring signal, set the timer to a short- er duration. Refer to...
Page 130
THOUBLESHOOTING Issue 2, June 1993 INTER-TEL PRACTICES GLX-PLUS INSTALLATION & MAINTENANCE FIGURE 6-3. CO LINE TROUBLESHOOTING CHART (CONT’D) SYMPTOM Other conversations can be heard on the line (crosstalk) I PROBABLE CAUSE Defective CO line(s) CO lines miswired Defective Expansion PCB or APM Defective Main Control PCB SYMPTOM I PROBABLE CAUSE Outside call dropped upon answering or during con- versation Database error I IAPM - CORRECTIVE ACTION I Attach a lineman’s test set to...