4.ClickUpgradeFirmware. Theselectedmanagementprocessorsareupgraded.Althoughthisutilityenablesyouto upgradehundredsofmanagementprocessors,only25managementprocessorsareupgraded simultaneously.Networkactivityisconsiderableduringthisprocess. 5.Aftertheupgradeiscomplete,clickNext. Duringthefirmwareupgradeprocess,allbuttonsaredeactivatedtopreventnavigation.Youcan stillclosetheapplicationbyclickingtheXatthetoprightofthepage.IftheGUIisclosedduring programmingoffirmware,theapplicationcontinuestoruninthebackgroundandcompletesthe firmwareupgradeonallselecteddevices. Selectingadirectoryaccessmethod AfteryouclickNextintheUpgradeFirmwareonManagementProcessorswindow,theSelectthe DesiredConfigurationwindowappears(Figure112).Youcanselectwhichmanagementprocessors toconfigure(withrespecttoschemausage)andhowtoconfigurethem.TheSelecttheDesired ConfigurationwindowhelpstopreventanaccidentaloverwriteofiLOsalreadyconfiguredforHP schema,oriLOsthathavedirectoriesturnedoff. Theselectionsyoumakeinthiswindowdeterminethewindowsthataredisplayedwhenyouclick Next. Figure112SelecttheDesiredConfigurationwindow Toconfigurethemanagementprocessorfordirectoryservices,see“Configuringdirectorieswhen HPextendedschemaisselected”(page202).ToconfigurethemanagementprocessorforSchema-free (defaultschema)directoriessupport,see“Configuringdirectorieswhenschema-freeintegrationis selected”(page206). HPDirectoriesSupportforProLiantManagementProcessorsutility201
Namingmanagementprocessors TheNamethemanagementprocessorswindow(Figure113)enablesyoutonameiLOmanagement deviceobjectsinthedirectoryandcreatecorrespondingdeviceobjectsforallmanagement processorstobemanaged.Youcancreatenamesbyusingoneormoreofthefollowing: •Thenetworkaddress •TheDNSname •Anindex •Manualcreationofthename •Theadditionofaprefixtoall •Theadditionofasuffixtoall Tonamethemanagementprocessors,clicktheObjectNamecolumnandenterthename,ordo thefollowing: 1.SelectUseiLONames,CreateNameUsingIndex,orUseNetworkAddress. 2.Optional:Enterthetexttoadd(suffixorprefix)toallnames. 3.ClickCreateNames. ThenamesappearintheObjectNamecolumnastheyaregenerated.Atthispoint,names arenotwrittentothedirectoryorthemanagementprocessors.Thenamesarestoreduntilthe nextHPDirectoriesSupportforProLiantManagementProcessorswindowisdisplayed. 4.Optional:Tochangethenames,clickClearNames,andrenamethemanagementprocessors. 5.Whenthenamesarecorrect,clickNext. Figure113Namethemanagementprocessorswindow ConfiguringdirectorieswhenHPextendedschemaisselected TheConfigureDirectorywindow(Figure114)enablesyoutocreateadeviceobjectforeach discoveredmanagementprocessorandtoassociatethenewdeviceobjectwithapreviouslydefined 202Directoryservices
role.Forexample,thedirectorydefinesauserasamemberofarole(suchasadministrator)who hasacollectionofprivilegesonaspecificdeviceobject,asshowninFigure114(page203). TheboxesontheConfigureDirectorywindowfollow: •NetworkAddress—Thenetworkaddressofthedirectoryserver,whichcanbeavalidDNS nameorIPaddress. •Port—TheSSLporttothedirectory.Thedefaultportis636.Managementprocessorscan communicatewiththedirectoryonlybyusingSSL. •LoginNameandPassword—Entertheloginnameandpasswordforanaccountthathas domainadministratoraccesstothedirectory. •ContainerDN—Afteryouhavethenetworkaddress,port,andlogininformation,youcanclick BrowsetosearchforthecontainerDN.Thecontaineriswherethemigrationutilitywillcreate themanagementprocessorobjectsinthedirectory. •RoleDN—Afteryouhavethenetworkaddress,port,andlogininformation,youcanclick BrowsetosearchfortheroleDN.Theroleiswheretheroletobeassociatedwiththedevice objectsresides.Therolemustbecreatedbeforeyourunthisutility. Figure114ConfigureDirectorywindow Toconfigurethedeviceobjectstobeassociatedwitharole: 1.Enterthenetworkaddress,loginname,andpasswordforthedesignateddirectoryserver. 2.EnterthecontainerDNintheContainerDNbox,orclickBrowse,asshowninFigure115 (page204). HPDirectoriesSupportforProLiantManagementProcessorsutility203
Figure115Enteringthecontainerdistinguishedname 3.AssociatedeviceobjectswithamemberofarolebyenteringtheroleDNintheRole(s)DN box,orclickBrowse,asshowninFigure116(page204). Figure116Enteringtheroledistinguishedname 204Directoryservices
4.ClickUpdateDirectory. Theutilityconnectstothedirectory,createsthemanagementprocessorobjects,andadds themtotheselectedroles. 5.Afterthedeviceobjectshavebeenassociatedwitharole,clickNext. ThevaluesyouenteredaredisplayedintheConfigureDirectorywindow(Figure117). Figure117ConfigureDirectorywindow 6.Definetheusercontexts. TheusercontextsdefinewheretheuserswhowilllogintoiLOarelocatedintheLDAPstructure. YoucanentertheorganizationalunitDNorclickBrowse. HPDirectoriesSupportforProLiantManagementProcessorsutility205
Figure118Definingtheusercontexts 7.ClickConfigure,andthenclickDonewhenbuttonisavailable. Configuringdirectorieswhenschema-freeintegrationisselected TheboxesontheConfigureManagementProcessorswindow(Figure119)follow: •NetworkAddress—Thenetworkaddressofthedirectoryserver,whichcanbeavalidDNS nameorIPaddress. •LoginNameandPassword—Entertheloginnameandpasswordforanaccountthathas domainadministratoraccesstothedirectory. •SecurityGroupDistinguishedName—TheDNofthegroupinthedirectorythatcontainsaset ofiLOuserswithacommonsetofprivileges.Ifthedirectoryname,loginname,andpassword arecorrect,youcanclickBrowsetonavigatetoandselectthegroup. •Privileges—TheiLOprivilegesassociatedwiththeselectedgroup.Theloginprivilegeisimplied iftheuserisamemberofthegroup. ConfigureManagementProcessorssettingsarestoreduntilthenextwindowinthewizardis displayed. 206Directoryservices
Figure119ConfigureManagementProcessorswindow Settingupmanagementprocessorsfordirectories Thelaststepinthemigrationprocessistoconfigurethemanagementprocessorstocommunicate withthedirectory.TheSetupManagementProcessorsforDirectorieswindow(Figure120)enables youtocreateusercontexts. Usercontextsenabletheusertouseshortnamesoruserobjectnamestologin,ratherthanthe fullDN.Forexample,havingausercontextsuchasCN=Users,DC=iLOTEST2,DC=HPenables userElizabethBennetttologinusingElizabeth BennettratherthanCN=Elizabeth Bennett,CN=Users, DC=iLOTEST2,[email protected], @iLOTEST2.HPinacontextboxenablestheusertologinusingebennett(assumingthat ebennettistheusershortname). Toconfigurethemanagementprocessorstocommunicatewiththedirectory: 1.Entertheusercontexts,orclickBrowse. 2.ClickConfigure. Themigrationutilityconnectstoallselectedmanagementprocessorsandupdatestheir configurationsasspecified.Theutilitysupportsconfiguring15usercontexts.Toaccessthe usercontextboxes,usethescrollbar. HPDirectoriesSupportforProLiantManagementProcessorsutility207
Figure120SetupManagementProcessorsforDirectorieswindow WhenyouclickConfigure,theutilitymightdisplayamessagesimilartothefollowing: 3.ClickOKtocontinue. 4.Whentheprocessiscomplete,clickDone. 208Directoryservices
7Troubleshooting iLO3POSTLEDindicators DuringtheinitialbootofiLO,thePOSTLEDindicatorsflashtodisplaytheprogressthroughthe iLObootprocess.Afterthebootprocessiscomplete,theHBLEDflashesinonesecondintervals. LEDindicators(1through6)lightupafterthesystemhasbootedtoindicateahardwarefailure. Ifahardwarefailureisdetected,resetiLO.ForthelocationoftheLEDindicators,refertotheserver documentation. AruntimefailureofiLOisindicatedbyHBremainingineithertheOnorOffstateconstantly.A runtimefailureofiLOcanalsobeindicatedbyarepeatedflashingpatternonalleightLEDs.Ifa runtimeerroroccurs,resetiLO. TheLEDindicatorshavethefollowingassignments: 1234567HB FailureindicatedDescriptionPOSTcode(activity completed) LEDindicator Setupchipselects00None Scrubdone02–Normaloperation2 Subsystemstartupfailedif thisstatusremainsfor Kernellaunch82HBand2 extendedperiodoftime (~60seconds) Themainpayloadiscorrupt, thekernelisrunningflash recovery. MainError-Recovery0F5,4,3,2,1blinking Failuretofindandloada kernel KernelErrorE0HB,7,and6steady 5,4,3,2,1blinking FlashesastheiLOprocessor executesfirmwarecode.It HB doesnotchangethevalue ofthelowersevenLEDs. Kerneldebugging UsetheWindowsWindbgkerneldebuggerfromalocaltestsystem(usuallyalaptop)forahost serverthatyouwanttodebug.ThismethodusestheiLOVirtualSerialPortfeature. NOTE:YoumusthavePuTTYinstalledonyourtestsystem.YoucandownloadPuTTYfromhttp:// www.putty.org/. 1.UsingtheiLOwebinterfaceonthehostserverwithkernelissues,navigatetothe Administration→AccessSettingspageandconfiguretheSerialCommandLineInterfaceSpeed setting. 2.ConfigurethedebugoptionsinWindows(theboot.iniparametersfortheserialconnection). Usedebugport=com2,andsetthebaudratetomatchthesettingsintheiLOwebinterface. 3.DuringPOST,pressF9toenterthesystemRBSU. 4.Fromthemainmenu,disableEMSandBIOSSerialConsole. Fordetailedinstructions,seetheHPROM-BasedSetupUtilityUserGuide. iLO3POSTLEDindicators209
5.SettheVirtualSerialPorttoCOM 2. Fordetailedinstructions,seetheHPROM-BasedSetupUtilityUserGuide. 6.RebootthehostservertoaccesstheselectionmenufortheWindowsdebugbootoption. 7.Fromthelocaltestsystem,usePuTTYtoconnecttoiLOandlogin. ThisisaCLIconnectiontoiLO. 8.EntertheIPaddressforthesessionhostname.UsethedefaultsettingsforanSSHsession. WhenthePuTTYiLOCLIsessionopens,auserloginwindowopens,unlessthePuTTYsession isconfiguredtouseprivatekeys.Formoreinformation,see“ConfiguringiLOsecurity” (page43)and“AdministeringSSHkeys”(page46). Itmighttakeaminutefortheprompttoappear. 9.AtthehpiLO->prompt,enterthefollowingcommand: windbg_enable ThisopensasockettotheVirtualSerialPortonport3002. 10.EnterthefollowingcommandtostarttheWindowsdebugger: windbg -k com:port=,ipport=3002 istheiLOIPaddress,and3002isthesockettoconnectto(therawserial datasocketforiLO). NOTE:Youcanaddotherwindbgcommand-lineparametersifnecessary.HPrecommends usingthe-bparameterfortheinitialbreakpoint. 11.Gototheserverconsole(oraccesstheiLORemoteConsole),andpressEntertobootthe debugselectionontheOSloadmenu. Thismighttakeseveralminutes. 12.Whenyouarefinisheddebuggingthehostserver,usePuTTYtoconnecttotheCLIandturn offthedebugsockettotheVirtualSerialPort.Then,enterthefollowingcommand: windbg_disable NOTE:YoucandisconnectandreconnecttheWindowsdebuggeraslongasyoukeepthe iLOdebugsocketenabled. Eventlogentries Table11(page210)liststypicaliLOeventlogentries. Table11Eventlogentries DescriptionEventlogentry Theserverpowerwasremoved.Server power removed TheIPaddressforthebrowserthatloggedin.Browser login: Theserverpowerwasrestored.Server power restored TheIPaddressforthebrowserthatloggedout.Browser logout: Theserverwasreset.Server reset Abrowserloginfailed.Failed Browser login ? IP Address: iLOfailedaninternaltest.Theprobablecauseisfailureofacriticalcomponent. FurtheruseofiLOonthisserverisnotrecommended. iLO Self Test Error: # 210Troubleshooting