    							4.ClickUpgradeFirmware.
    Theselectedmanagementprocessorsareupgraded.Althoughthisutilityenablesyouto
    upgradehundredsofmanagementprocessors,only25managementprocessorsareupgraded
    simultaneously.Networkactivityisconsiderableduringthisprocess.
    5.Aftertheupgradeiscomplete,clickNext.
    Duringthefirmwareupgradeprocess,allbuttonsaredeactivatedtopreventnavigation.Youcan
    stillclosetheapplicationbyclickingtheXatthetoprightofthepage.IftheGUIisclosedduring
    programmingoffirmware,theapplicationcontinuestoruninthebackgroundandcompletesthe
    firmwareupgradeonallselecteddevices.
    Selectingadirectoryaccessmethod
    AfteryouclickNextintheUpgradeFirmwareonManagementProcessorswindow,theSelectthe
    DesiredConfigurationwindowappears(Figure112).Youcanselectwhichmanagementprocessors
    toconfigure(withrespecttoschemausage)andhowtoconfigurethem.TheSelecttheDesired
    ConfigurationwindowhelpstopreventanaccidentaloverwriteofiLOsalreadyconfiguredforHP
    schema,oriLOsthathavedirectoriesturnedoff.
    Theselectionsyoumakeinthiswindowdeterminethewindowsthataredisplayedwhenyouclick
    Next.
    Figure112SelecttheDesiredConfigurationwindow
    Toconfigurethemanagementprocessorfordirectoryservices,see“Configuringdirectorieswhen
    HPextendedschemaisselected”(page202).ToconfigurethemanagementprocessorforSchema-free
    (defaultschema)directoriessupport,see“Configuringdirectorieswhenschema-freeintegrationis
    selected”(page206).
    HPDirectoriesSupportforProLiantManagementProcessorsutility201 
    						
    							Namingmanagementprocessors
    TheNamethemanagementprocessorswindow(Figure113)enablesyoutonameiLOmanagement
    deviceobjectsinthedirectoryandcreatecorrespondingdeviceobjectsforallmanagement
    processorstobemanaged.Youcancreatenamesbyusingoneormoreofthefollowing:
    •Thenetworkaddress
    •TheDNSname
    •Anindex
    •Manualcreationofthename
    •Theadditionofaprefixtoall
    •Theadditionofasuffixtoall
    Tonamethemanagementprocessors,clicktheObjectNamecolumnandenterthename,ordo
    thefollowing:
    1.SelectUseiLONames,CreateNameUsingIndex,orUseNetworkAddress.
    2.Optional:Enterthetexttoadd(suffixorprefix)toallnames.
    3.ClickCreateNames.
    ThenamesappearintheObjectNamecolumnastheyaregenerated.Atthispoint,names
    arenotwrittentothedirectoryorthemanagementprocessors.Thenamesarestoreduntilthe
    nextHPDirectoriesSupportforProLiantManagementProcessorswindowisdisplayed.
    4.Optional:Tochangethenames,clickClearNames,andrenamethemanagementprocessors.
    5.Whenthenamesarecorrect,clickNext.
    Figure113Namethemanagementprocessorswindow
    ConfiguringdirectorieswhenHPextendedschemaisselected
    TheConfigureDirectorywindow(Figure114)enablesyoutocreateadeviceobjectforeach
    discoveredmanagementprocessorandtoassociatethenewdeviceobjectwithapreviouslydefined
    202Directoryservices 
    						
    							role.Forexample,thedirectorydefinesauserasamemberofarole(suchasadministrator)who
    hasacollectionofprivilegesonaspecificdeviceobject,asshowninFigure114(page203).
    TheboxesontheConfigureDirectorywindowfollow:
    •NetworkAddress—Thenetworkaddressofthedirectoryserver,whichcanbeavalidDNS
    nameorIPaddress.
    •Port—TheSSLporttothedirectory.Thedefaultportis636.Managementprocessorscan
    communicatewiththedirectoryonlybyusingSSL.
    •LoginNameandPassword—Entertheloginnameandpasswordforanaccountthathas
    domainadministratoraccesstothedirectory.
    •ContainerDN—Afteryouhavethenetworkaddress,port,andlogininformation,youcanclick
    BrowsetosearchforthecontainerDN.Thecontaineriswherethemigrationutilitywillcreate
    themanagementprocessorobjectsinthedirectory.
    •RoleDN—Afteryouhavethenetworkaddress,port,andlogininformation,youcanclick
    BrowsetosearchfortheroleDN.Theroleiswheretheroletobeassociatedwiththedevice
    objectsresides.Therolemustbecreatedbeforeyourunthisutility.
    Figure114ConfigureDirectorywindow
    Toconfigurethedeviceobjectstobeassociatedwitharole:
    1.Enterthenetworkaddress,loginname,andpasswordforthedesignateddirectoryserver.
    2.EnterthecontainerDNintheContainerDNbox,orclickBrowse,asshowninFigure115
    (page204).
    HPDirectoriesSupportforProLiantManagementProcessorsutility203 
    						
    							Figure115Enteringthecontainerdistinguishedname
    3.AssociatedeviceobjectswithamemberofarolebyenteringtheroleDNintheRole(s)DN
    box,orclickBrowse,asshowninFigure116(page204).
    Figure116Enteringtheroledistinguishedname
    204Directoryservices 
    						
    							4.ClickUpdateDirectory.
    Theutilityconnectstothedirectory,createsthemanagementprocessorobjects,andadds
    themtotheselectedroles.
    5.Afterthedeviceobjectshavebeenassociatedwitharole,clickNext.
    ThevaluesyouenteredaredisplayedintheConfigureDirectorywindow(Figure117).
    Figure117ConfigureDirectorywindow
    6.Definetheusercontexts.
    TheusercontextsdefinewheretheuserswhowilllogintoiLOarelocatedintheLDAPstructure.
    YoucanentertheorganizationalunitDNorclickBrowse.
    HPDirectoriesSupportforProLiantManagementProcessorsutility205 
    						
    							Figure118Definingtheusercontexts
    7.ClickConfigure,andthenclickDonewhenbuttonisavailable.
    Configuringdirectorieswhenschema-freeintegrationisselected
    TheboxesontheConfigureManagementProcessorswindow(Figure119)follow:
    •NetworkAddress—Thenetworkaddressofthedirectoryserver,whichcanbeavalidDNS
    nameorIPaddress.
    •LoginNameandPassword—Entertheloginnameandpasswordforanaccountthathas
    domainadministratoraccesstothedirectory.
    •SecurityGroupDistinguishedName—TheDNofthegroupinthedirectorythatcontainsaset
    ofiLOuserswithacommonsetofprivileges.Ifthedirectoryname,loginname,andpassword
    arecorrect,youcanclickBrowsetonavigatetoandselectthegroup.
    •Privileges—TheiLOprivilegesassociatedwiththeselectedgroup.Theloginprivilegeisimplied
    iftheuserisamemberofthegroup.
    ConfigureManagementProcessorssettingsarestoreduntilthenextwindowinthewizardis
    displayed.
    206Directoryservices 
    						
    							Figure119ConfigureManagementProcessorswindow
    Settingupmanagementprocessorsfordirectories
    Thelaststepinthemigrationprocessistoconfigurethemanagementprocessorstocommunicate
    withthedirectory.TheSetupManagementProcessorsforDirectorieswindow(Figure120)enables
    youtocreateusercontexts.
    Usercontextsenabletheusertouseshortnamesoruserobjectnamestologin,ratherthanthe
    fullDN.Forexample,havingausercontextsuchasCN=Users,DC=iLOTEST2,DC=HPenables
    userElizabethBennetttologinusingElizabeth BennettratherthanCN=Elizabeth
    Bennett,CN=Users, DC=iLOTEST2,[email protected],
    @iLOTEST2.HPinacontextboxenablestheusertologinusingebennett(assumingthat
    ebennettistheusershortname).
    Toconfigurethemanagementprocessorstocommunicatewiththedirectory:
    1.Entertheusercontexts,orclickBrowse.
    2.ClickConfigure.
    Themigrationutilityconnectstoallselectedmanagementprocessorsandupdatestheir
    configurationsasspecified.Theutilitysupportsconfiguring15usercontexts.Toaccessthe
    usercontextboxes,usethescrollbar.
    HPDirectoriesSupportforProLiantManagementProcessorsutility207 
    						
    							Figure120SetupManagementProcessorsforDirectorieswindow
    WhenyouclickConfigure,theutilitymightdisplayamessagesimilartothefollowing:
    3.ClickOKtocontinue.
    4.Whentheprocessiscomplete,clickDone.
    208Directoryservices 
    						
    							7Troubleshooting
    iLO3POSTLEDindicators
    DuringtheinitialbootofiLO,thePOSTLEDindicatorsflashtodisplaytheprogressthroughthe
    iLObootprocess.Afterthebootprocessiscomplete,theHBLEDflashesinonesecondintervals.
    LEDindicators(1through6)lightupafterthesystemhasbootedtoindicateahardwarefailure.
    Ifahardwarefailureisdetected,resetiLO.ForthelocationoftheLEDindicators,refertotheserver
    documentation.
    AruntimefailureofiLOisindicatedbyHBremainingineithertheOnorOffstateconstantly.A
    runtimefailureofiLOcanalsobeindicatedbyarepeatedflashingpatternonalleightLEDs.Ifa
    runtimeerroroccurs,resetiLO.
    TheLEDindicatorshavethefollowingassignments:
    1234567HB
    FailureindicatedDescriptionPOSTcode(activity
    completed)
    LEDindicator
    Setupchipselects00None
    Scrubdone02–Normaloperation2
    Subsystemstartupfailedif
    thisstatusremainsfor
    Kernellaunch82HBand2
    extendedperiodoftime
    (~60seconds)
    Themainpayloadiscorrupt,
    thekernelisrunningflash
    recovery.
    MainError-Recovery0F5,4,3,2,1blinking
    Failuretofindandloada
    kernel
    KernelErrorE0HB,7,and6steady
    5,4,3,2,1blinking
    FlashesastheiLOprocessor
    executesfirmwarecode.It
    HB
    doesnotchangethevalue
    ofthelowersevenLEDs.
    Kerneldebugging
    UsetheWindowsWindbgkerneldebuggerfromalocaltestsystem(usuallyalaptop)forahost
    serverthatyouwanttodebug.ThismethodusestheiLOVirtualSerialPortfeature.
    NOTE:YoumusthavePuTTYinstalledonyourtestsystem.YoucandownloadPuTTYfromhttp://
    www.putty.org/.
    1.UsingtheiLOwebinterfaceonthehostserverwithkernelissues,navigatetothe
    Administration→AccessSettingspageandconfiguretheSerialCommandLineInterfaceSpeed
    setting.
    2.ConfigurethedebugoptionsinWindows(theboot.iniparametersfortheserialconnection).
    Usedebugport=com2,andsetthebaudratetomatchthesettingsintheiLOwebinterface.
    3.DuringPOST,pressF9toenterthesystemRBSU.
    4.Fromthemainmenu,disableEMSandBIOSSerialConsole.
    Fordetailedinstructions,seetheHPROM-BasedSetupUtilityUserGuide.
    iLO3POSTLEDindicators209 
    						
    							5.SettheVirtualSerialPorttoCOM 2.
    Fordetailedinstructions,seetheHPROM-BasedSetupUtilityUserGuide.
    6.RebootthehostservertoaccesstheselectionmenufortheWindowsdebugbootoption.
    7.Fromthelocaltestsystem,usePuTTYtoconnecttoiLOandlogin.
    ThisisaCLIconnectiontoiLO.
    8.EntertheIPaddressforthesessionhostname.UsethedefaultsettingsforanSSHsession.
    WhenthePuTTYiLOCLIsessionopens,auserloginwindowopens,unlessthePuTTYsession
    isconfiguredtouseprivatekeys.Formoreinformation,see“ConfiguringiLOsecurity”
    (page43)and“AdministeringSSHkeys”(page46).
    Itmighttakeaminutefortheprompttoappear.
    9.AtthehpiLO->prompt,enterthefollowingcommand:
    windbg_enable
    ThisopensasockettotheVirtualSerialPortonport3002.
    10.EnterthefollowingcommandtostarttheWindowsdebugger:
    windbg -k com:port=,ipport=3002
    istheiLOIPaddress,and3002isthesockettoconnectto(therawserial
    datasocketforiLO).
    NOTE:Youcanaddotherwindbgcommand-lineparametersifnecessary.HPrecommends
    usingthe-bparameterfortheinitialbreakpoint.
    11.Gototheserverconsole(oraccesstheiLORemoteConsole),andpressEntertobootthe
    debugselectionontheOSloadmenu.
    Thismighttakeseveralminutes.
    12.Whenyouarefinisheddebuggingthehostserver,usePuTTYtoconnecttotheCLIandturn
    offthedebugsockettotheVirtualSerialPort.Then,enterthefollowingcommand:
    windbg_disable
    NOTE:YoucandisconnectandreconnecttheWindowsdebuggeraslongasyoukeepthe
    iLOdebugsocketenabled.
    Eventlogentries
    Table11(page210)liststypicaliLOeventlogentries.
    Table11Eventlogentries
    DescriptionEventlogentry
    Theserverpowerwasremoved.Server power removed
    TheIPaddressforthebrowserthatloggedin.Browser login: 
    Theserverpowerwasrestored.Server power restored
    TheIPaddressforthebrowserthatloggedout.Browser logout: 
    Theserverwasreset.Server reset
    Abrowserloginfailed.Failed Browser login ? IP
    Address: 
    iLOfailedaninternaltest.Theprobablecauseisfailureofacriticalcomponent.
    FurtheruseofiLOonthisserverisnotrecommended.
    iLO Self Test Error: #
    210Troubleshooting 
    						