Page 151

10 - 13
Centering Centering OnDECWIN13-7
*Centering Off
DECWIN03-7
Left of Centering Win-
dow *40
DECLFT###3-7
Right of Centering Win-
dow *60
DECRGT###3-7
Preferred Symbology On
PRFENA13-8
*Off
PRFENA03-8
High Priority Symbol-
ogy
PRFCOD##3-9
Low Priority Symbology
PRFBLK##3-9
Preferred Symbology 
Timeout (*500) Range 
100-3000
PRFPTO####
3-9
Preferred Symbology 
Default
PRFDFT3-9
Output Sequence Edi-
torEnter Sequence
SEQBLK3-11
Default Sequence
SEQDFT3-11
Require Output 
SequenceRequired
SEQ_EN23-11...

Page 152

10 - 14
Suffix Add Suffix SUFBK2##4-4
Clear One Suffix SUFCL24-4
Clear All Suffixes SUFCA24-4
Function Code Trans-
mit*Enable RMVFNC04-4
Disable RMVFNC14-4
Intercharacter Delay DLYCHR##4-5
User Specified Inter-
character DelayDelay Length DLYCRX##4-5
Character to Trigger 
DelayDLY_XX###4-5
Interfunction Delay DLYFNC##4-6
Intermessage Delay DLYMSG##4-6
Data Formatter Selections
Data Format Editor *Default Data Format 
(None)DFMDF35-4
Enter Data Format DFMBK3##5-4
Clear One Data Format DFMCL35-4
Clear All...

Page 153

10 - 15
Codabar Start/Stop 
Char.*Don’t Transmit CBRSSX06-3
Transmit CBRSSX16-3
Codabar Check Char.*No Check Char. CBRCK206-4
Validate, But Don’t 
TransmitCBRCK216-4
Validate, and Transmit CBRCK226-4
Codabar Concatena-
tionOff CBRCCT06-4
On CBRCCT16-4
Require CBRCCT26-4
Codabar Message 
LengthMinimum (2 - 60)  *4 CBRMIN##6-5
Maximum (2 - 60)  *60 CBRMAX##6-5
Code 39 Default All Code 39 
SettingsC39DFT6-5
Code 39 Off C39ENA06-5
*On C39ENA16-5
Code 39 Start/Stop 
Char.*Don’t Transmit C39SSX06-5
Transmit...

Page 154

10 - 16
Interleaved 2 of 5 Off I25ENA06-9
*On I25ENA16-9
Interleaved 2 of 5 
Check Digit*No Check Char. I25CK206-10
Validate, But Don’t 
Tr a n s m i tI25CK216-10
Validate, and Transmit I25CK226-10
Interleaved 2 of 5 Mes-
sage LengthMinimum (2 - 80)  *4 I25MIN##6-10
Maximum (2 - 80)  *80 I25MAX##6-10
Code 93 Default All Code 93 
SettingsC93DFT6-11
Code 93 Off C93ENA06-11
*On C93ENA16-11
Code 93 Message 
LengthMinimum (0 - 80)  *0 C93MIN##6-11
Maximum (0 - 80)  *80 C93MAX##6-11
Straight 2 of 5 Indus-...

Page 155

10 - 17
Matrix 2 of 5 Message 
LengthMinimum (1 - 80)  *4 X25MIN##6-14
Maximum (1 - 80)  *80 X25MAX##6-14
Code 11 Default All Code 11 
SettingsC11DFT6-14
Code 11 *Off C11ENA06-14
On C11ENA16-14
Code 11 Check Digits 
Required1 Check Digit C11CK206-14
*2 Check Digits C11CK216-14
Code 11 Message 
LengthMinimum (1 - 80)  *4 C11MIN##6-15
Maximum (1 - 80)  *80 C11MAX##6-15
Code 128 Default All Code 128
Settings128DFT6-15
Code 128 Off 128ENA06-16
*On 128ENA16-15
ISBT Concatenation On ISBENA16-16
*Off...

Page 156

10 - 18
UPC A Default All 
UPC A SettingsUPADFT6-18
UPC A Off UPAENA06-18
*On UPAENA16-18
UPC A Check Digit Off UPACKX06-18
*On UPACKX16-18
UPC A Number Sys-
temOff UPANSX06-19
*On UPANSX16-19
UPC A 2 Digit 
Addenda*Off UPAAD206-19
On UPAAD216-19
UPC A 5 Digit 
Addenda*Off UPAAD506-19
On UPAAD516-19
UPC A Addenda 
Required*Not Required UPAARQ06-19
Required UPAARQ16-19
UPC A Addenda 
SeparatorOff UPAADS06-20
*On UPAADS16-20
UPC E Default All UPC E
SettingsUPEDFT6-21
UPC E0 Off UPEEN006-21
*On UPEEN016-21...

Page 157

10 - 19
UPC E 5 Digit 
Addenda*Off UPEAD506-23
On UPEAD516-23
UPC E Addenda 
Required*Not Required UPEARQ06-21
Required UPEARQ16-21
UPC E Addenda 
SeparatorOff UPEADS06-22
*On UPEADS16-22
EAN/JAN 13 Default All EAN/
JAN 13 SettingsE13DFT6-23
EAN/JAN 13 Off E13ENA06-23
*On E13ENA16-23
EAN/JAN 13 Check 
DigitOff E13CKX06-23
*On E13CKX16-23
EAN/JAN 13 2 Digit 
Addenda*Off E13AD206-24
On E13AD216-24
EAN/JAN 13 5 Digit 
Addenda*Off E13AD506-24
On E13AD516-24
EAN/JAN 13 Addenda 
Required*Not Required...

Page 158

10 - 20
EAN/JAN 8 5 Digit 
Addenda*Off EA8AD506-26
On EA8AD516-26
EAN/JAN 8 Addenda 
Required*Not Required EA8ARQ06-26
Required EA8ARQ16-26
EAN/JAN 8 Addenda 
SeparatorOff EA8ADS06-26
*On EA8ADS16-26
Coupon Code Off CPNENA06-26
*On CPNENA16-20
MSI Default All MSI Settings MSIDFT6-27
MSI *Off MSIENA06-27
On MSIENA16-27
MSI Check Character *Validate Type 10, but 
Don’t TransmitMSICHK06-27
Validate Type 10 and 
Tr a n s m i tMSICHK16-27
MSI Message Length Minimum (4 - 48) *4 MSIMIN##6-27
Maximum (4 - 48)...

Page 159

10 - 21
GS1 DataBar 
ExpandedDefault All GS1 Data-
Bar
Expanded SettingsRSEDFT6-30
GS1 DataBar 
ExpandedOff RSEENA06-30
*On RSEENA16-30
GS1 DataBar 
Expanded Msg. 
LengthMinimum (4 - 74) *4 RSEMIN##6-30
Maximum (4 - 74) *74 RSEMAX##6-30
 GS1 DataBar Emula-
tionEANEMU26-30
128 Emulation EANEMU16-30

OffEANEMU06-30
China Post Code Default All China Post 
Code SettingsCPCDFT6-31
China Post Code *Off CPCENA06-31
On CPCENA16-31
China Post Code Msg. 
LengthMinimum (2 - 80) *4 CPCMIN##6-31
Maximum (2 - 80) *80...

Page 160

10 - 22
Pos iCo de Off P OS ENA 06-32
*On POSENA16-32
A and B On POSLIM06-33
A and B and Limited A 
OnPOSLIM16-33
*A and B and Limited B 
OnPOSLIM26-33
PosiCode Msg. Length Minimum (2 - 80) *4 POSMIN##6-33
Maximum (2 - 80) *48 POSMAX##6-33
Codablock  F Default All Codablock F 
SettingsCBFDFT6-34
Codablock F *Off CBFENA06-34
On CBFENA16-34
Codablock F Msg. 
LengthMinimum (1 - 2048) *1 CBFMIN####6-34
Maximum (1 - 2048) 
*2048CBFMAX####6-34
Code 16K Default All Code 16K 
Settings16KDFT6-34
Code 16K *Off...