Home > Honeywell > Scanner > Honeywell 20205 Manual

Honeywell 20205 Manual

Here you can view all the pages of manual Honeywell 20205 Manual. The Honeywell manuals for Scanner are available online for free. You can easily download all the documents as PDF.

Page 121

6 - 31
China Post Code

China Post Code
China Post Message Length
Scan the bar codes below to change the message length.  Refer to Message 
Lengthon page 6-2 for additional information.  Minimum and Maximum
lengths = 2-80.   Minimum Default = 4, Maximum Default = 80.
On
* Off
Minimum Message Length
Maximum Message Length 

Page 122

6 - 32
Korea Post Code

Korea Post Code
Korea Post Message Length
Scan the bar codes below to change the message length.  Refer to Message 
Lengthon page 6-2 for additional information.  Minimum and Maximum
lengths = 2-80.   Minimum Default = 4, Maximum Default = 48.
PosiCode

PosiCode A and B
On
* Off
Minimum Message Length
Maximum Message Length
* On
Off 

Page 123

6 - 33
You have to have PosiCode A and B on to read any of the PosiCode symbolo-
gies.
PosiCode Message Length
Scan the bar codes below to change the message length.  Refer to Message 
Lengthon page 6-2 for additional information.  Minimum and Maximum
lengths = 2-80.   Minimum Default = 4, Maximum Default = 48.
A and B On
(No Limited)
A and B and Limited A On
(Limited B Off)
* A and B and Limited B On
(Limited A Off)
Minimum Message Length
Maximum Message Length 

Page 124

6 - 34
Codablock F

Codablock F
Codablock F Message Length
Scan the bar codes below to change the message length.  Refer to Message 
Lengthon page 6-2 for additional information.  Minimum and Maximum
lengths = 1-2048.   Minimum Default = 1, Maximum Default = 2048.
Code 16K

On
* Off
Minimum Message Length
Maximum Message Length 

Page 125

6 - 35
Code 16K
Code 16K Message Length
Scan the bar codes below to change the message length.  Refer to Message 
Lengthon page 6-2 for additional information.  Minimum and Maximum
lengths = 0-160.   Minimum Default = 1, Maximum Default = 160.
Code 49

Code 49
On
* Off
Minimum Message Length
Maximum Message Length
* On
Off 

Page 126

6 - 36
Code 49 Message Length
Scan the bar codes below to change the message length.  Refer to Message 
Lengthon page 6-2 for additional information.    Minimum and Maximum
lengths = 1-81.   Minimum Default = 1, Maximum Default = 81.
Minimum Message Length
Maximum Message Length 

Page 127

7 - 1
7
Interface Keys
Keyboard Function Relationships
The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII 
“CTRL”+  relationships apply to all terminals that can be used with the image 
scanner.  Refer to page 2-7 enable Control + ASCII mode.
Function Code HEX/ASCII Value Full ASCII “CTRL” +
NUL 00 @
SOH 01 A
STX 02 B
ETX 03 C
EOT 04 D
ENQ 05 E
ACK 06 F
BEL 07 G
BS 08 H
HT 09 I
LF 0A J
VT 0B K
FF 0C L
CR 0D M
SO 0E N
SI 0F O
DLE 10 P
DC1 11 Q
DC2 12 R
DC3 13 S
DC4 14 T
NAK 15 U
SYN 16...

Page 128

7 - 2
The last five characters in the Full ASCII “CTRL”+ column  ( [  ] 6 - ), apply to 
US only.  The following chart indicates the equivalents of these five characters 
for different countries.
Country Codes
United States[\]6-
Belgium [

Page 129

7 - 3
Supported Interface Keys
ASCIIHEX
IBM AT/XT and 
PS/2 Compatibles, 
WYSE PC/AT
Supported Keys
IBM XTs and 
Compatibles
Supported KeysIBM, DDC, Memorex 
Telex, Harris*
Supported Keys
NUL 00 Reserved Reserved Reserved
SOH 01 Enter (KP) CR/Enter Enter
STX 02 Cap Lock Caps Lock F11
ETX 03 ALT make Reserved F12
EOT 04 ALT break Reserved F13
ENQ 05 CTRL make Reserved F14
ACK 06 CTRL break Reserved F15
BEL 07 CR/Enter CR/Enter New Line
BS 08 Reserved Reserved F16
HT 09 Tab Tab F17
LF 0A Reserved Reserved...

Page 130

7 - 4
Supported Interface Keys
 
ASCII
HEX
IBM, Memorex Telex (102)*
Supported KeysMemorex Telex (88)**
Supported Keys
NUL 00 Reserved Reserved
SOH 01 Enter Enter
STX 02 F11 PF10
ETX 03 F12 PF11
EOT 04 F13 PF12
ENQ 05 F14 Reserved
ACK 06 F15 Reserved
BEL 07 New Line New Line
BS 08 F16 Field Forward
HT 09 F17 Field Forward
LF 0A F18 Reserved
VT 0B Tab/Field Forward Field Forward
FF 0C Delete Delete
CR 0D Field Exit New Line
SO 0E Insert Insert
SI 0F Clear Erase
DLE 10 Error Reset Error Reset
DC1 11 Home...
Start reading Honeywell 20205 Manual

Related Manuals for Honeywell 20205 Manual

All Honeywell manuals