Page 141

10 - 3
Responses
The device responds to serial commands with one of three responses:
ACKIndicates a good command which has been processed.
ENQIndicates an invalid Tag or SubTag command. 
NAKIndicates the command was good, but the Data field entry was out of the 
allowable range for this Tag and SubTag combination, e.g., an entry for a mini-
mum message length of 100 when the field will only accept 2 characters.
When responding, the device echoes back the command sequence with the 
status character...

Page 142

10 - 4
Example #4:  What are the device’s settings for all Codabar selections?
Enter: cbr?.
Response: CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
MAX60[ACK],
DFT[ACK].
This response indicates that the device’s Codabar Coding Enable (CBRENA) is 
set to 1, or on; 
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit; 
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled; 
the Minimum Message Length (MIN) is set to 2 characters; 
the...

Page 143

10 - 5
The Menu Commands starting on page 10-6 list the factory default settings for 
each of the commands (indicated by an asterisk (*) on the programming pages).
Note: Scanning this bar code also causes both the image scanner and the base 
to perform a reset and become unlinked.  Refer to Linking Image 
Scanner to Baseon page 1-5 for additional information.
Note: If your image scanner is in multiple image scanner mode and you scan 
either the current or all application group default bar code, you will...

Page 144

10 - 6
Menu Commands
SelectionSetting* Indicates default
Serial 
Command
# Indicates a 
numeric entryPage
Base Charge Mode *Automatic
BASCHG11-4
Full Charge Rate
BASCHG21-4
Low Charge Rate
BASCHG31-4
Battery Charge Off
BASCHG41-4
Image Scanner Modes 
- SingleUnlink Image Scanner
BT_RMV1-5
*Locked Link Mode
BASCON0,DNG11-6
Open Link Mode
BASCON1,DNG11-6
Override Locked Image 
Scanner
BT_RPL11-6
Multiple Image Scan-
ner
OperationMultiple Image Scan-
ner Operation
BASCON2,DNG3
1-7
Image Scanner NameImage...

Page 145

10 - 7
Out-of-Range Alarm Base Alarm Duration 
(Range 1 - 3000 sec 
(*0))
BASORD
1-13
Image Scanner Alarm 
Duration (Range 1 - 
3000 sec (*0))
BT_ORD1-13
Alarm Sound Type Base Alarm Type
BASORW1-13
Image Scanner Alarm 
Ty p e
BT_ORW1-13
Data Accumulation 
ModeOn
BATENA11-13
*Off
BATENA01-13
Batch Mode Transmit 
Delay*Off
BATDLY01-14
Short (ms)
BATDLY2501-14
Medium (ms)
BATDLY5001-14
Long (ms)
BATDLY10001-14
Factory Default Set-
tingsDefault
DEFALT1-20
Terminal Interfaces
Terminal ID *003TERMID###2-2...

Page 146

10 - 8
Program Keyboard 
Country*U.S.A.KBDCTY02-4
Belgium
KBDCTY12-4
Brazil
KBDCTY162-4
Canada (French)
KBDCTY182-4
Czech Republic
KBDCTY152-4
Denmark
KBDCTY82-4
Finland (Sweden)
KBDCTY22-4
France
KBDCTY32-4
Germany/Austria
KBDCTY42-4
Greece
KBDCTY172-4
Hungary
KBDCTY192-4
Israel (Hebrew)
KBDCTY122-4
Italy
KBDCTY52-5
Latin America
KBDCTY142-5
Netherlands (Dutch)
KBDCTY112-5
Norway
KBDCTY92-5
Pola nd
KBDCTY202-5
Portugal
KBDCTY132-5
Romania
KBDCTY252-5
Russia
KBDCTY262-5
SCS
KBDCTY212-5
Slovakia...

Page 147

10 - 9
Keyboard Style *RegularKBDSTY02-6
Caps Lock
KBDSTY12-6
Shift Lock
KBDSTY22-6
Automatic Caps Lock
KBDSTY62-6
Emulate External
Keyboard
KBDSTY52-6
Keyboard Modifiers *Control + ASCII Off
KBDCAS02-7
Control + ASCII On
KBDCAS22-7
*Turbo Mode Off
KBDTMD02-7
Turbo Mode On
KBDTMD12-7
*Numeric Keypad Off
KBDNPS02-7
Numeric Keypad On
KBDNPS12-7
*Auto Direct Conn. Off
KBDADC02-7
Auto Direct Conn. On
KBDADC12-7
Serial Port Connection RS-232
PAP2322-8
Baud Rate 300 BPS
232BAD02-9
600 BPS
232BAD12-9
1200 BPS...

Page 148

10 - 10
Word Length:  Data 
Bits, Stop Bits, and 
Par ity7 Data, 1 Stop, Parity 
Even232WRD32-10
7 Data, 1 Stop, Parity 
None
232WRD02-10
7 Data, 1 Stop, Parity 
Odd
232WRD62-10
7 Data, 2 Stop, Parity 
Even
232WRD42-10
7 Data, 2 Stop, Parity 
None
232WRD12-10
7 Data, 2 Stop, Parity 
Odd
232WRD72-10
8 Data, 1 Stop, Parity 
Even
232WRD52-10
*8 Data, 1 Stop, Parity 
None
232WRD22-10
8 Data, 1 Stop, Parity 
Odd
232WRD82-10
RS-232 Handshaking *RTS/CTS Off
232CTS02-11
RTS/CTS On
232CTS22-11
*XON/XOFF Off...

Page 149

10 - 11
Wand Emulation Polar-
ity*Black HighWNDPOL02-15
White High
WNDPOL12-15
Wand Emulation Idle Idle Low
WNDIDL02-15
*Idle High
WNDIDL12-15
Wand Emulation Data 
Block Size20
WNDBLK02-16
*40
WNDBLK12-16
60
WNDBLK22-16
80
WNDBLK32-16
Wand Emulation Delay 
Between Blocks5ms
WNDDLY02-16
*50ms
WNDDLY12-16
150ms
WNDDLY22-16
500ms
WNDDLY32-16
Wand Emulation Over-
all Checksum*Off
WNDCHK02-16
On
WNDCHK12-16
Output Selections
Beeper - Good Read  OffBEPBEP03-1
*On
BEPBEP13-1
Beeper Volume - Good 
ReadOff...

Page 150

10 - 12
Number of Beeps - 
Good Read *1BEPRPT13-2
Range 1 - 9
BEPRPT#3-2
Good Read Delay *No Delay
DLYGRD03-3
Short Delay (500 ms)
DLYGRD5003-3
Medium Delay (1000 
ms)
DLYGRD10003-3
Long Delay (1500 ms)
DLYGRD15003-3
User-Specified Good 
Read DelayRange 0 - 30,000 ms
DLYGRD#####3-3
Trigger Mode *Manual Trigger
TRGMOD03-3
Read Time-Out (0 - 
300,000 ms) *30,000
TRGSTO####3-4
Image Scanner Power 
Time-Out Timer (0-
7200 seconds) *3600
BT_LPT03-5
BT_LPT2003-5
BT_LPT4003-5
BT_LPT9003-5
BT_LPT36003-5...