Honeywell 20205 Manual
Have a look at the manual Honeywell 20205 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
10 - 3 Responses The device responds to serial commands with one of three responses: ACKIndicates a good command which has been processed. ENQIndicates an invalid Tag or SubTag command. NAKIndicates the command was good, but the Data field entry was out of the allowable range for this Tag and SubTag combination, e.g., an entry for a mini- mum message length of 100 when the field will only accept 2 characters. When responding, the device echoes back the command sequence with the status character inserted directly before each of the punctuation marks (the period, exclamation point, comma, or semicolon) in the command. Examples of Query Commands In the following examples, a bracketed notation [ ] depicts a non-displayable response. Example #1:What is the range of possible values for Codabar Coding Enable? Enter: cbrena*. Response: CBRENA0-1[ACK] This response indicates that Codabar Coding Enable (CBRENA) has a range of values from 0 to 1 (off and on). Example #2: What is the default value for Codabar Coding Enable? Enter: cbrena^. Response: CBRENA1[ACK] This response indicates that the default setting for Codabar Coding Enable (CBRENA) is 1, or on. Example #3: What is the device’s current setting for Codabar Coding Enable? Enter: cbrena?. Response: CBRENA1[ACK] This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on.
10 - 4 Example #4: What are the device’s settings for all Codabar selections? Enter: cbr?. Response: CBRENA1[ACK], SSX0[ACK], CK20[ACK], CCT1[ACK], MIN2[ACK], MAX60[ACK], DFT[ACK]. This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on; the Start/Stop Character (SSX) is set to 0, or Don’t Transmit; the Check Character (CK2) is set to 0, or Not Required; concatenation (CCT) is set to 1, or Enabled; the Minimum Message Length (MIN) is set to 2 characters; the Maximum Message Length (MAX) is set to 60 characters; and the Default setting (DFT) has no value. Trigger Commands You can activate and deactivate the image scanner with serial trigger com- mands. First, the image scanner must be put in Manual/Serial Trigger Mode either by scanning the Manual/Serial Trigger Mode bar code (page 3-3), or by sending the Manual/Serial Menu Command (page 10-12). Once the image scanner is in serial trigger mode, the trigger is activated and deactivated by sending the following commands: Activate:SYN T CR Deactivate:SYN U CR The image scanner scans until a bar code has been read, until the deactivate command is sent, or until the serial time-out has been reached (see Read Time-Out (Serial Trigger Mode)on page 3-4 for a description, and the serial command on page 10-12). Resetting the Standard Product Default Settings: Current Application Work Group If you aren’t sure what programming options are in your image scanner, or you’ve changed some options and want the standard product default settings restored, scan the Standard Product Default Settings: Current Application Group bar code below.
10 - 5 The Menu Commands starting on page 10-6 list the factory default settings for each of the commands (indicated by an asterisk (*) on the programming pages). Note: Scanning this bar code also causes both the image scanner and the base to perform a reset and become unlinked. Refer to Linking Image Scanner to Baseon page 1-5 for additional information. Note: If your image scanner is in multiple image scanner mode and you scan either the current or all application group default bar code, you will hear up to 30 seconds of beeping while all image scanners are re-linked from the base and the settings are defaulted to * settings. The default interface is keyboard wedge and the default image scanner mode is single image scanner locked link mode. Resetting the Standard Product Default Settings: All Application Work Groups The following bar code defaults all of the work groups to the factory settings. The Menu Commands starting on page 10-6 list the standard product default settings for each of the commands (indicated by an asterisk (*) on the program- ming pages). Standard Product Default Settings: Current Application Group Standard Product Default Settings: All Application Groups
10 - 6 Menu Commands SelectionSetting* Indicates default Serial Command # Indicates a numeric entryPage Base Charge Mode *Automatic BASCHG11-4 Full Charge Rate BASCHG21-4 Low Charge Rate BASCHG31-4 Battery Charge Off BASCHG41-4 Image Scanner Modes - SingleUnlink Image Scanner BT_RMV1-5 *Locked Link Mode BASCON0,DNG11-6 Open Link Mode BASCON1,DNG11-6 Override Locked Image Scanner BT_RPL11-6 Multiple Image Scan- ner OperationMultiple Image Scan- ner Operation BASCON2,DNG3 1-7 Image Scanner NameImage Scanner Name BT_NAM1-8 Image Scanner Report Image Scanner Report RPTSCN1-9 Application Work Group Selections*Group 0 GRPSEL01-10 Group 1 GRPSEL11-10 Group 2 GRPSEL21-10 Group 3 GRPSEL31-10 Group 4 GRPSEL41-10 Group 5 GRPSEL51-10 Group 6 GRPSEL61-10 Standard Product Defaults: Current Application Work GroupDefault - Current Work Group DEFALT 1-11 Standard Product Defaults: All Applica- tion Work GroupsDefault - All Work Groups PAPDFT 1-11 Non-Base Bluetooth ConnectionNon-Base BT Connec- tion BT_DNG51-12 Bluetooth PIN Code Bluetooth PIN BT_PIN1-12
10 - 7 Out-of-Range Alarm Base Alarm Duration (Range 1 - 3000 sec (*0)) BASORD 1-13 Image Scanner Alarm Duration (Range 1 - 3000 sec (*0)) BT_ORD1-13 Alarm Sound Type Base Alarm Type BASORW1-13 Image Scanner Alarm Ty p e BT_ORW1-13 Data Accumulation ModeOn BATENA11-13 *Off BATENA01-13 Batch Mode Transmit Delay*Off BATDLY01-14 Short (ms) BATDLY2501-14 Medium (ms) BATDLY5001-14 Long (ms) BATDLY10001-14 Factory Default Set- tingsDefault DEFALT1-20 Terminal Interfaces Terminal ID *003TERMID###2-2 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage
10 - 8 Program Keyboard Country*U.S.A.KBDCTY02-4 Belgium KBDCTY12-4 Brazil KBDCTY162-4 Canada (French) KBDCTY182-4 Czech Republic KBDCTY152-4 Denmark KBDCTY82-4 Finland (Sweden) KBDCTY22-4 France KBDCTY32-4 Germany/Austria KBDCTY42-4 Greece KBDCTY172-4 Hungary KBDCTY192-4 Israel (Hebrew) KBDCTY122-4 Italy KBDCTY52-5 Latin America KBDCTY142-5 Netherlands (Dutch) KBDCTY112-5 Norway KBDCTY92-5 Pola nd KBDCTY202-5 Portugal KBDCTY132-5 Romania KBDCTY252-5 Russia KBDCTY262-5 SCS KBDCTY212-5 Slovakia KBDCTY222-5 Spain KBDCTY102-5 Sweden KBDCTY232-5 Switzerland (German) KBDCTY62-5 Tu r k e y F KBDCTY272-5 Tu r k e y Q KBDCTY242-5 U.K. KBDCTY72-5 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage
10 - 9 Keyboard Style *RegularKBDSTY02-6 Caps Lock KBDSTY12-6 Shift Lock KBDSTY22-6 Automatic Caps Lock KBDSTY62-6 Emulate External Keyboard KBDSTY52-6 Keyboard Modifiers *Control + ASCII Off KBDCAS02-7 Control + ASCII On KBDCAS22-7 *Turbo Mode Off KBDTMD02-7 Turbo Mode On KBDTMD12-7 *Numeric Keypad Off KBDNPS02-7 Numeric Keypad On KBDNPS12-7 *Auto Direct Conn. Off KBDADC02-7 Auto Direct Conn. On KBDADC12-7 Serial Port Connection RS-232 PAP2322-8 Baud Rate 300 BPS 232BAD02-9 600 BPS 232BAD12-9 1200 BPS 232BAD22-9 2400 BPS 232BAD32-9 4800 BPS 232BAD42-9 9600 BPS 232BAD52-9 19200 BPS 232BAD62-9 38400 BPS 232BAD72-9 57600 BPS 232BAD82-9 *115200 BPS 232BAD92-9 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage
10 - 10 Word Length: Data Bits, Stop Bits, and Par ity7 Data, 1 Stop, Parity Even232WRD32-10 7 Data, 1 Stop, Parity None 232WRD02-10 7 Data, 1 Stop, Parity Odd 232WRD62-10 7 Data, 2 Stop, Parity Even 232WRD42-10 7 Data, 2 Stop, Parity None 232WRD12-10 7 Data, 2 Stop, Parity Odd 232WRD72-10 8 Data, 1 Stop, Parity Even 232WRD52-10 *8 Data, 1 Stop, Parity None 232WRD22-10 8 Data, 1 Stop, Parity Odd 232WRD82-10 RS-232 Handshaking *RTS/CTS Off 232CTS02-11 RTS/CTS On 232CTS22-11 *XON/XOFF Off 232XON02-11 XON/XOFF On 232XON12-11 *ACK/NAK Off 232ACK02-11 ACK/NAK On 232ACK12-11 Wand Emulation Con- nectionSame Code Format TERMID642-14 Code 39 Format TERMID612-14 Wand Emulation Transmission Rate10 WNDSPD02-15 *25 WNDSPD12-15 40 WNDSPD22-15 80 WNDSPD32-15 120 WNDSPD42-15 150 WNDSPD52-15 200 WNDSPD62-15 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage
10 - 11 Wand Emulation Polar- ity*Black HighWNDPOL02-15 White High WNDPOL12-15 Wand Emulation Idle Idle Low WNDIDL02-15 *Idle High WNDIDL12-15 Wand Emulation Data Block Size20 WNDBLK02-16 *40 WNDBLK12-16 60 WNDBLK22-16 80 WNDBLK32-16 Wand Emulation Delay Between Blocks5ms WNDDLY02-16 *50ms WNDDLY12-16 150ms WNDDLY22-16 500ms WNDDLY32-16 Wand Emulation Over- all Checksum*Off WNDCHK02-16 On WNDCHK12-16 Output Selections Beeper - Good Read OffBEPBEP03-1 *On BEPBEP13-1 Beeper Volume - Good ReadOff BEPLVL03-1 Low BEPLVL13-1 *Medium BEPLVL23-1 High BEPLVL33-1 Beeper Pitch - Good Read (Frequency)Low (1600) (min 400Hz) BEPFQ116003-2 *Medium (3250) BEPFQ132503-2 High (4200) (max 9000Hz) BEPFQ142003-2 Beeper Duration - Good Read*Normal Beep BEPBIP03-2 Short Beep BEPBIP13-2 LED - Good Read Off BEPLED03-2 *On BEPLED13-2 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage
10 - 12 Number of Beeps - Good Read *1BEPRPT13-2 Range 1 - 9 BEPRPT#3-2 Good Read Delay *No Delay DLYGRD03-3 Short Delay (500 ms) DLYGRD5003-3 Medium Delay (1000 ms) DLYGRD10003-3 Long Delay (1500 ms) DLYGRD15003-3 User-Specified Good Read DelayRange 0 - 30,000 ms DLYGRD#####3-3 Trigger Mode *Manual Trigger TRGMOD03-3 Read Time-Out (0 - 300,000 ms) *30,000 TRGSTO####3-4 Image Scanner Power Time-Out Timer (0- 7200 seconds) *3600 BT_LPT03-5 BT_LPT2003-5 BT_LPT4003-5 BT_LPT9003-5 BT_LPT36003-5 BT_LPT72003-5 Automatic Trigger TRGMOD13-5 Presentation Mode TRGMOD33-5 Hands Free Time-Out (0-300,000 seconds) *5000 TRGPTO###### 3-6 Reread Delay Short (500 ms) DLYRRD5003-6 *Medium (750 ms) DLYRRD7503-6 Long (1000 ms) DLYRRD10003-6 Extra Long (2000 ms) DLYRRD30003-6 User-Specified Reread DelayRange 0 - 30,000 ms DLYRRD#####3-6 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage