10 - 13 Centering Centering OnDECWIN13-7 *Centering Off DECWIN03-7 Left of Centering Win- dow *40 DECLFT###3-7 Right of Centering Win- dow *60 DECRGT###3-7 Preferred Symbology On PRFENA13-8 *Off PRFENA03-8 High Priority Symbol- ogy PRFCOD##3-9 Low Priority Symbology PRFBLK##3-9 Preferred Symbology Timeout (*500) Range 100-3000 PRFPTO#### 3-9 Preferred Symbology Default PRFDFT3-9 Output Sequence Edi- torEnter Sequence SEQBLK3-11 Default Sequence SEQDFT3-11 Require Output SequenceRequired SEQ_EN23-11 On/Not Required SEQ_EN13-11 *Off SEQ_EN03-11 Multiple Symbols On SHOTGN13-14 *Off SHOTGN03-14 No Read On SHWNRD13-14 *Off SHWNRD03-14 Video Reverse On VIDREV13-13 *Off VIDREV03-13 Prefix/Suffix Selections Add CR Suffix to All Symbologies VSUFCR4-3 Prefix Add Prefix PREBK2##4-3 Clear One Prefix PRECL24-3 Clear All Prefixes PRECA24-3 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage
10 - 14 Suffix Add Suffix SUFBK2##4-4 Clear One Suffix SUFCL24-4 Clear All Suffixes SUFCA24-4 Function Code Trans- mit*Enable RMVFNC04-4 Disable RMVFNC14-4 Intercharacter Delay DLYCHR##4-5 User Specified Inter- character DelayDelay Length DLYCRX##4-5 Character to Trigger DelayDLY_XX###4-5 Interfunction Delay DLYFNC##4-6 Intermessage Delay DLYMSG##4-6 Data Formatter Selections Data Format Editor *Default Data Format (None)DFMDF35-4 Enter Data Format DFMBK3##5-4 Clear One Data Format DFMCL35-4 Clear All Data Formats DFMCA35-4 Data Formatter Off DFM_EN05-4 *On, but Not Required DFM_EN15-4 On, Required DFM_EN25-5 Alternate Data For- mats1VSAF_15-5 2VSAF_25-5 3VSAF_35-5 Symbologies All Symbologies All Symbologies Off ALLENA06-1 All Symbologies On ALLENA16-1 Codabar Default All Codabar SettingsCBRDFT6-3 Codabar Off CBRENA06-3 *On CBRENA16-3 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage
10 - 15 Codabar Start/Stop Char.*Don’t Transmit CBRSSX06-3 Transmit CBRSSX16-3 Codabar Check Char.*No Check Char. CBRCK206-4 Validate, But Don’t TransmitCBRCK216-4 Validate, and Transmit CBRCK226-4 Codabar Concatena- tionOff CBRCCT06-4 On CBRCCT16-4 Require CBRCCT26-4 Codabar Message LengthMinimum (2 - 60) *4 CBRMIN##6-5 Maximum (2 - 60) *60 CBRMAX##6-5 Code 39 Default All Code 39 SettingsC39DFT6-5 Code 39 Off C39ENA06-5 *On C39ENA16-5 Code 39 Start/Stop Char.*Don’t Transmit C39SSX06-5 Transmit C39SSX16-5 Code 39 Check Char.*No Check Char. C39CK206-6 Validate, But Don’t TransmitC39CK216-6 Va l i d a t e , and TransmitC39CK226-6 Code 39 Message LengthMinimum (0 - 48) *0 C39MIN##6-6 Maximum (0 - 48) *48 C39MAX##6-6 Code 39 Append *Off C39APP06-7 On C39APP16-7 Code 32 Pharmaceuti- cal (PARAF)*Off C39B3206-7 On C39B3216-7 Code 39 Full ASCII *Off C39ASC06-8 On C39ASC16-8 Interleaved 2 of 5 Default All Interleaved 2 of 5 SettingsI25DFT6-9 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage
10 - 16 Interleaved 2 of 5 Off I25ENA06-9 *On I25ENA16-9 Interleaved 2 of 5 Check Digit*No Check Char. I25CK206-10 Validate, But Don’t Tr a n s m i tI25CK216-10 Validate, and Transmit I25CK226-10 Interleaved 2 of 5 Mes- sage LengthMinimum (2 - 80) *4 I25MIN##6-10 Maximum (2 - 80) *80 I25MAX##6-10 Code 93 Default All Code 93 SettingsC93DFT6-11 Code 93 Off C93ENA06-11 *On C93ENA16-11 Code 93 Message LengthMinimum (0 - 80) *0 C93MIN##6-11 Maximum (0 - 80) *80 C93MAX##6-11 Straight 2 of 5 Indus- trialDefault All Straight 2 of 5 Industrial SettingsR25DFT6-12 Straight 2 of 5 Indus- trial*Off R25ENA06-12 On R25ENA16-12 Straight 2 of 5 Indus- trial Message LengthMinimum (1 - 48) *4 R25MIN##6-12 Maximum (1 - 48) *48 R25MAX##6-12 Straight 2 of 5 IATA Default All Straight 2 of 5 IATA SettingsA25DFT6-13 Straight 2 of 5 IATA *Off A25ENA06-13 On A25ENA16-13 Straight 2 of 5 IATA Message LengthMinimum (1 - 48) *4 A25MIN##6-13 Maximum (1 - 48) *48 A25MAX##6-13 Matrix 2 of 5 Default All Matrix 2 of 5 SettingsX25DFT6-13 Matrix 2 of 5 *Off X25ENA06-13 On X25ENA16-13 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage
10 - 17 Matrix 2 of 5 Message LengthMinimum (1 - 80) *4 X25MIN##6-14 Maximum (1 - 80) *80 X25MAX##6-14 Code 11 Default All Code 11 SettingsC11DFT6-14 Code 11 *Off C11ENA06-14 On C11ENA16-14 Code 11 Check Digits Required1 Check Digit C11CK206-14 *2 Check Digits C11CK216-14 Code 11 Message LengthMinimum (1 - 80) *4 C11MIN##6-15 Maximum (1 - 80) *80 C11MAX##6-15 Code 128 Default All Code 128 Settings128DFT6-15 Code 128 Off 128ENA06-16 *On 128ENA16-15 ISBT Concatenation On ISBENA16-16 *Off ISBENA06-16 Code 128 Message LengthMinimum (0 - 80) *0 128MIN##6-16 Maximum (0 - 80) *80 128MAX##6-16 Code 128 Code Page Code 128 Code Page 128DCP6-16 Code 128 Function Code Transmit*Off 128FNX06-17 On 128FNX16-17 ISBT Concatenation *Off ISBENA06-16 On ISBENA16-16 Telepen Default All Telepen SettingsTELDFT6-17 Telepen *Off TELENA06-17 On TELENA16-17 Telepen Output *AIM Telepen Output TELOLD06-17 Original Telepen Out- putTELOLD16-17 Telepen Message LengthMinimum (1 - 60) *1 TELMIN##6-18 Maximum (1 - 60) *60 TELMAX##6-18 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage
10 - 18 UPC A Default All UPC A SettingsUPADFT6-18 UPC A Off UPAENA06-18 *On UPAENA16-18 UPC A Check Digit Off UPACKX06-18 *On UPACKX16-18 UPC A Number Sys- temOff UPANSX06-19 *On UPANSX16-19 UPC A 2 Digit Addenda*Off UPAAD206-19 On UPAAD216-19 UPC A 5 Digit Addenda*Off UPAAD506-19 On UPAAD516-19 UPC A Addenda Required*Not Required UPAARQ06-19 Required UPAARQ16-19 UPC A Addenda SeparatorOff UPAADS06-20 *On UPAADS16-20 UPC E Default All UPC E SettingsUPEDFT6-21 UPC E0 Off UPEEN006-21 *On UPEEN016-21 UPC E1 *Off UPEEN106-21 On UPEEN116-21 UPC E Expand *Off UPEEXP06-21 On UPEEXP16-21 UPC E Check Digit Off UPECKX06-22 *On UPECKX16-22 UPC E Number Sys- temOff UPENSX06-22 *On UPENSX16-22 UPC E 2 Digit Addenda*Off UPEAD206-23 On UPEAD216-23 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage
10 - 19 UPC E 5 Digit Addenda*Off UPEAD506-23 On UPEAD516-23 UPC E Addenda Required*Not Required UPEARQ06-21 Required UPEARQ16-21 UPC E Addenda SeparatorOff UPEADS06-22 *On UPEADS16-22 EAN/JAN 13 Default All EAN/ JAN 13 SettingsE13DFT6-23 EAN/JAN 13 Off E13ENA06-23 *On E13ENA16-23 EAN/JAN 13 Check DigitOff E13CKX06-23 *On E13CKX16-23 EAN/JAN 13 2 Digit Addenda*Off E13AD206-24 On E13AD216-24 EAN/JAN 13 5 Digit Addenda*Off E13AD506-24 On E13AD516-24 EAN/JAN 13 Addenda Required*Not Required E13ARQ06-24 Required E13ARQ16-24 EAN/JAN 13 Addenda SeparatorOff E13ADS06-24 *On E13ADS16-24 ISBN Translate *Off E13ISB06-25 On E13ISB16-25 EAN/JAN 8 Default All EAN/ JAN 8 SettingsEA8DFT6-25 EAN/JAN 8 Off EA8ENA06-25 *On EA8ENA16-25 EAN/JAN 8 Check DigitOff EA8CKX06-25 *On EA8CKX16-25 EAN/JAN 8 2 Digit Addenda*Off EA8AD206-26 On EA8AD216-26 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage
10 - 20 EAN/JAN 8 5 Digit Addenda*Off EA8AD506-26 On EA8AD516-26 EAN/JAN 8 Addenda Required*Not Required EA8ARQ06-26 Required EA8ARQ16-26 EAN/JAN 8 Addenda SeparatorOff EA8ADS06-26 *On EA8ADS16-26 Coupon Code Off CPNENA06-26 *On CPNENA16-20 MSI Default All MSI Settings MSIDFT6-27 MSI *Off MSIENA06-27 On MSIENA16-27 MSI Check Character *Validate Type 10, but Don’t TransmitMSICHK06-27 Validate Type 10 and Tr a n s m i tMSICHK16-27 MSI Message Length Minimum (4 - 48) *4 MSIMIN##6-27 Maximum (4 - 48) *48 MSIMAX##6-27 Plessey Code Default All Plessey Set- tingsPLSDFT6-28 Plessey Code *Off PLSENA06-28 On PLSENA16-28 Plessey Message LengthMinimum (4 - 48) *4 PLSMIN##6-28 Maximum (4 - 48) *48 PLSMAX##6-28 GS1 DataBar Default All GS1 DataBar SettingsRSSDFT6-29 GS1 DataBar Off RSSENA06-29 *On RSSENA16-29 GS1 DataBar Limited Default All GS1 Data- Bar Limited SettingsRSLDFT6-29 GS1 DataBar Limited Off RSLENA06-29 *On RSLENA16-29 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage
10 - 21 GS1 DataBar ExpandedDefault All GS1 Data- Bar Expanded SettingsRSEDFT6-30 GS1 DataBar ExpandedOff RSEENA06-30 *On RSEENA16-30 GS1 DataBar Expanded Msg. LengthMinimum (4 - 74) *4 RSEMIN##6-30 Maximum (4 - 74) *74 RSEMAX##6-30 GS1 DataBar Emula- tionEANEMU26-30 128 Emulation EANEMU16-30 OffEANEMU06-30 China Post Code Default All China Post Code SettingsCPCDFT6-31 China Post Code *Off CPCENA06-31 On CPCENA16-31 China Post Code Msg. LengthMinimum (2 - 80) *4 CPCMIN##6-31 Maximum (2 - 80) *80 CPCMAX##6-31 Korea Post Code Default All Korea Post Code SettingsKPCDFT6-32 Korea Post Code *Off KPCENA06-32 On KPCENA16-32 Korea Post Code Msg. LengthMinimum (2 - 80) *4 KPCMIN##6-32 Maximum (2 - 80) *48 KPCMAX##6-32 PosiCode Default All PosiCode SettingsPOSDFT6-32 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage
10 - 22 Pos iCo de Off P OS ENA 06-32 *On POSENA16-32 A and B On POSLIM06-33 A and B and Limited A OnPOSLIM16-33 *A and B and Limited B OnPOSLIM26-33 PosiCode Msg. Length Minimum (2 - 80) *4 POSMIN##6-33 Maximum (2 - 80) *48 POSMAX##6-33 Codablock F Default All Codablock F SettingsCBFDFT6-34 Codablock F *Off CBFENA06-34 On CBFENA16-34 Codablock F Msg. LengthMinimum (1 - 2048) *1 CBFMIN####6-34 Maximum (1 - 2048) *2048CBFMAX####6-34 Code 16K Default All Code 16K Settings16KDFT6-34 Code 16K *Off 16KENA06-35 On 16KENA16-35 Code 16K Minimum (0 - 160) *1 16KMIN###6-35 Maximum (0 - 160) *16016KMAX###6-35 Code 49 Default All Code 49 SettingsC49DFT6-35 Code 49 Off C49ENA06-35 *On C49ENA16-35 Code 49 Minimum (1 - 81) *1 C49MIN##6-36 Maximum (1 - 81) *81 C49MAX##6-36 Minimizing Bluetooth/ISM Band Network Activity Auto Reconnect Mode *On BT_ACM1B-1 Off BT_ACM0B-1 SelectionSetting * Indicates default Serial Command # Indicates a numeric entryPage