6 - 31 China Post Code China Post Code China Post Message Length Scan the bar codes below to change the message length. Refer to Message Lengthon page 6-2 for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80. On * Off Minimum Message Length Maximum Message Length
6 - 32 Korea Post Code Korea Post Code Korea Post Message Length Scan the bar codes below to change the message length. Refer to Message Lengthon page 6-2 for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 48. PosiCode PosiCode A and B On * Off Minimum Message Length Maximum Message Length * On Off
6 - 33 You have to have PosiCode A and B on to read any of the PosiCode symbolo- gies. PosiCode Message Length Scan the bar codes below to change the message length. Refer to Message Lengthon page 6-2 for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 48. A and B On (No Limited) A and B and Limited A On (Limited B Off) * A and B and Limited B On (Limited A Off) Minimum Message Length Maximum Message Length
6 - 34 Codablock F Codablock F Codablock F Message Length Scan the bar codes below to change the message length. Refer to Message Lengthon page 6-2 for additional information. Minimum and Maximum lengths = 1-2048. Minimum Default = 1, Maximum Default = 2048. Code 16K On * Off Minimum Message Length Maximum Message Length
6 - 35 Code 16K Code 16K Message Length Scan the bar codes below to change the message length. Refer to Message Lengthon page 6-2 for additional information. Minimum and Maximum lengths = 0-160. Minimum Default = 1, Maximum Default = 160. Code 49 Code 49 On * Off Minimum Message Length Maximum Message Length * On Off
6 - 36 Code 49 Message Length Scan the bar codes below to change the message length. Refer to Message Lengthon page 6-2 for additional information. Minimum and Maximum lengths = 1-81. Minimum Default = 1, Maximum Default = 81. Minimum Message Length Maximum Message Length
7 - 1 7 Interface Keys Keyboard Function Relationships The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships apply to all terminals that can be used with the image scanner. Refer to page 2-7 enable Control + ASCII mode. Function Code HEX/ASCII Value Full ASCII “CTRL” + NUL 00 @ SOH 01 A STX 02 B ETX 03 C EOT 04 D ENQ 05 E ACK 06 F BEL 07 G BS 08 H HT 09 I LF 0A J VT 0B K FF 0C L CR 0D M SO 0E N SI 0F O DLE 10 P DC1 11 Q DC2 12 R DC3 13 S DC4 14 T NAK 15 U SYN 16 V ETB 17 W CAN 18 X EM 19 Y SUB 1A Z ESC 1B [ FS 1C \ GS 1D ] RS 1E ^ US 1F _
7 - 2 The last five characters in the Full ASCII “CTRL”+ column ( [ ] 6 - ), apply to US only. The following chart indicates the equivalents of these five characters for different countries. Country Codes United States[\]6- Belgium [
7 - 3 Supported Interface Keys ASCIIHEX IBM AT/XT and PS/2 Compatibles, WYSE PC/AT Supported Keys IBM XTs and Compatibles Supported KeysIBM, DDC, Memorex Telex, Harris* Supported Keys NUL 00 Reserved Reserved Reserved SOH 01 Enter (KP) CR/Enter Enter STX 02 Cap Lock Caps Lock F11 ETX 03 ALT make Reserved F12 EOT 04 ALT break Reserved F13 ENQ 05 CTRL make Reserved F14 ACK 06 CTRL break Reserved F15 BEL 07 CR/Enter CR/Enter New Line BS 08 Reserved Reserved F16 HT 09 Tab Tab F17 LF 0A Reserved Reserved F18 VT 0B Tab Tab Tab/Field Forward FF 0C Delete Delete Delete CR 0D CR/Enter CR/Enter Field Exit/New Line SO 0E Insert Insert Insert SI 0F Escape Escape F19 DLE 10 F11 Reserved Error Reset DC1 11 Home Home Home DC2 12 Print Print F20 DC3 13 Back Space Back Space Back Space DC4 14 Back Tab Back Tab Backfield/Back Tab NAK 15 F12 Reserved F21 SYN 16 F1 F1 F1 ETB 17 F2 F2 F2 CAN 18 F3 F3 F3 EM 19 F4 F4 F4 SUB 1A F5 F5 F5 ESC 1B F6 F6 F6 FS 1C F7 F7 F7 GS 1D F8 F8 F8 RS 1E F9 F9 F9 US 1F F10 F10 F10 * IBM 3191/92, 3471/72, 3196/97, 3476/77, Telex (all models)
7 - 4 Supported Interface Keys ASCII HEX IBM, Memorex Telex (102)* Supported KeysMemorex Telex (88)** Supported Keys NUL 00 Reserved Reserved SOH 01 Enter Enter STX 02 F11 PF10 ETX 03 F12 PF11 EOT 04 F13 PF12 ENQ 05 F14 Reserved ACK 06 F15 Reserved BEL 07 New Line New Line BS 08 F16 Field Forward HT 09 F17 Field Forward LF 0A F18 Reserved VT 0B Tab/Field Forward Field Forward FF 0C Delete Delete CR 0D Field Exit New Line SO 0E Insert Insert SI 0F Clear Erase DLE 10 Error Reset Error Reset DC1 11 Home Reserved DC2 12 Print Print DC3 13 Back Space Back Space DC4 14 Back Tab Back Field NAK 15 F19 Reserved SYN 16 F1 PF1 ETB 17 F2 PF2 CAN 18 F3 PF3 EM 19 F4 PF4 SUB 1A F5 PF5 ESC 1B F6 PF6 FS 1C F7 PF7 GS 1D F8 PF8 RS 1E F9 PF9 US 1F F10 Home * IBM 3196/97, 3476/77, 3191/92, 3471/72, Memorex Telex (all models) with 102 key keyboards ** Memorex Telex with 88 key keyboards