Honeywell 1300g2 Manual
Have a look at the manual Honeywell 1300g2 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 178 Honeywell manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
2 - 5 USB PC or Macintosh Keyboard Scan one of the following codes to program the scanner for USB PC Keyboard or USB Macintosh Keyboard. Scanning these codes also adds a CR and LF. USB HID POS Scan the following code to program the scanner for USB HID POS bar code scanners. USB Serial Commands USB Serial Emulation Scan the following code to program the scanner to emulate a regular RS232- based COM Port. If you are using a Microsoft® Windows® PC, you will need to download a driver from the Honeywell website (www.honeywellaidc.com). The driver will use the next available COM Port number. Apple® Macintosh comput- ers recognize the scanner as a USB CDC class device and automatically uses a class driver. Scanning this code also adds a CR and LF. Note: No extra configuration (e.g., baud rate) is necessary. U SB K ey b o a rd ( P C) USB Keyboard (Mac) USB HID POS Bar Code Scanner USB Serial Emulation
2 - 6 CTS/RTS Emulation ACK/NAK Mode Honeywell Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner for a Honeywell bioptic scanner auxiliary port configuration. This bar code sets the baud rate to 38400 bps and the data format to 8 data bits, no parity, 1 stop bit. Character RTS/CTS with timeout and 232 ACK/NAK are also enabled. Note: If you are having unexpected results with this programming code, scan the Resetting the Custom Defaultsbar code on page 1-5 first, then scan the programming code above. CTS/RTS Emulation On * CTS/RTS Emulation Off ACK/NAK Mode On * ACK/NAK Mode Off Honeywell Bioptic Settings
2 - 7 Datalogic™ Magellan®Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner for a Datalogic Magellan bioptic scanner auxiliary port configuration. This bar code sets the baud rate to 9600 bps and the data format to 8 data bits, no parity, 1 stop bit. Note: If you are having unexpected results with this programming code, scan the Resetting the Custom Defaultsbar code on page 1-5 first, then scan the programming code above. Wincor Mode A Scan the following Plug and Play code to program the scanner for Wincor Mode A mode. This bar code sets the baud rate to 9600 bps and the data format to 8 data bits, odd parity, 1 stop bit. Note: If you are having unexpected results with this programming code, scan the Resetting the Custom Defaultsbar code on page 1-5 first, then scan the programming code above. Datalogic Magellan Bioptic Settings Wincor Mode A
2 - 8 Keyboard Country Layout Scan the appropriate country code below to program the keyboard layout for your country or language. As a general rule, the following characters are sup- ported, but need special care for countries other than the United States: @ | $ # { } [ ] = / ‘ < > ~ * United States Albania Arabic Azeri (Cyrillic) Azeri (Latin) Belarus Belgium Bosnia
2 - 9 Brazil Brazil (MS) Bulgaria (Cyrillic) Bulgaria (Latin) Canada (French legacy) Canada (French) Canada (Multilingual) China Croatia
2 - 10 Czech Czech (Programmers) Czech (QWERTY) Czech (QWERTZ) Denmark Dutch (Netherlands) Estonia Faroese Finland
2 - 11 France Gaelic Germany Greek Greek (220 Latin) Greek (220) Greek (319 Latin) Greek (319) Greek (Latin)
2 - 12 Greek (MS) Greek (Polytonic) Hebrew Hungarian (101 key) Hungary Iceland Ireland Italian (142) Italy
2 - 13 Japan ASCII Kazakh Korea Kyrgyz (Cyrillic) Latin America Latvia Latvia (QWERTY) Lithuania Lithuania (IBM)
2 - 14 Macedonia Malta Mongolian (Cyrillic) Norway Poland Polish (214) Polish (Programmers) Portugal Romania