6 - 5 Codabar Concatenation Codabar supports symbol concatenation. When you enable concatenation, the scanner looks for a Codabar symbol having a “D” start character, adjacent to a symbol having a “D” stop character. In this case the two messages are concat- enated into one with the “D” characters omitted. Select Require to prevent the scanner from decoding a single “D” Codabar sym- bol without its companion. This selection has no effect on Codabar symbols without Stop/Start D characters. A12D D34A Codabar Character Stop Start Stop Start On * Off Require
6 - 6 Codabar Message Length Scan the bar codes below to change the message length. Refer to Message Lengthon page 6-2 for additional information. Minimum and Maximum lengths = 2-60. Minimum Default = 4, Maximum Default = 60. Minimum Message Length Maximum Message Length
6 - 7 Code 39 < Default All Code 39 Settings > Code 39 Code 39 Start / Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit. Code 39 Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character. When Check Character is set to Validate, but Don’t Transmit, the unit only reads Code 39 bar codes printed with a check character, but will not transmit the check character with the scanned data. *On Off Transmit * Don’t Transmit
6 - 8 When Check Character is set to Validate and Transmit, the scanner only reads Code 39 bar codes printed with a check character, and will transmit this charac- ter at the end of the scanned data. Default = No Check Character. Code 39 Message Length Scan the bar codes below to change the message length. Refer to Message Lengthon page 6-2 for additional information. Minimum and Maximum lengths = 0-48. Minimum Default = 0, Maximum Default = 48. Code 39 Append This function allows the scanner to append the data from several Code 39 bar codes together before transmitting them to the host computer. When this func- tion is enabled, the scanner stores those Code 39 bar codes that start with a space (excluding the start and stop symbols), and does not immediately trans- mit the data. The scanner stores the data in the order in which the bar codes Validate, but Don’t Transmit * No Check Character Validate and Transmit Minimum Message Length Maximum Message Length
6 - 9 are read, deleting the first space from each. The scanner transmits the appended data when it reads a Code 39 bar code that starts with a character other than a space. Default = Off. Code 32 Pharmaceutical (PARAF) Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian pharmacies. This symbology is also known as PARAF. Default = Off. *Off On * Off On
6 - 10 Full ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #. Default = Off. Character pairs /M and /N decode as a minus sign and period respectively. Character pairs /P through /Y decode as 0 through 9. Code 39 Code Page Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting. If this is the case, scan the bar code below, select the code page with which the bar codes were created from the chart, NUL %UDLE $PSP SPACE00@%VPP‘%Wp+P SOH $A DC1 $Q!/A11AAQQa+Aq+Q STX $B DC2 $R“/B22BBRRb+Br+R ETX $C DC3 $S#/C33CCSSc+Cs+S EOT $D DC4 $T$/D44DDTTd+Dt+T ENQ $E NAK $U%/E55EEUUe+Eu+U ACK $F SYN $V&/F66FFVVf+Fv+V BEL $G ETB $W‘/G77GGWWg+Gw+W BS $H CAN $X(/H88HHXXh+Hx+X HT $I EM $Y)/I99IIYYi+Iy+Y LF $J SUB $Z*/J:/ZJJZZj+Jz+Z VT $K ESC %A+/K;%FKK[%Kk+K{%P FF $L FS %B,/L%INN^%Nn+N~%S SI $O US %E//O?%JOO_%Oo+ODEL %T * Full ASCII Off Full ASCII On
6 - 11 ASCII Conversion Chart (Code Page 1252), page A-3, and scan the value and the Save bar code from the inside the back cover of this manual. The data characters should then appear properly. Interleaved 2 of 5 < Default All Interleaved 2 of 5 Settings > Interleaved 2 of 5 Check Digit No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit. When Check Digit is set to Validate, but Don’t Transmit, the unit only reads Interleaved 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data. Code 39 Code Page * On Off
6 - 12 When Check Digit is set to Validate and Transmit, the scanner only reads Interleaved 2 of 5 bar codes printed with a check digit, and will transmit this digit at the end of the scanned data. Default = No Check Digit. Interleaved 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Lengthon page 6-2 for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80. Validate, but Don’t Transmit * No Check Digit Validate and Transmit Minimum Message Length Maximum Message Length
6 - 13 Code 93 < Default All Code 93 Settings > Code 93 Code 93 Message Length Scan the bar codes below to change the message length. Refer to Message Lengthon page 6-2 for additional information. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80. Code 93 Code Page Code pages define the mapping of character codes to characters. If the data received does not display with the proper characters, it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting. If this is the case, scan the bar code below, * On Off Minimum Message Length Maximum Message Length
6 - 14 select the code page with which the bar codes were created from the chart, ASCII Conversion Chart (Code Page 1252), page A-3, and scan the value and the Save bar code from the inside the back cover of this manual. The data characters should then appear properly. Code 93 Code Page