    							6 - 35
    EAN/JAN 8
    EAN/JAN 8 Check Digit
    This selection allows you to specify whether the check digit should be transmit-
    ted at the end of the scanned data or not.  Default = On.
    *  On
    Off
    Off
    Off *  On 
    						
    							6 - 36
    EAN/JAN 8 Addenda
    This selection adds 2 or 5 digits to the end of all scanned EAN/JAN 8 data.
    Default = Off for both 2 Digit and 5 Digit Addenda.
    EAN/JAN 8 Addenda Required
    When Addenda Required is set to on, the scanner will only read EAN/JAN 8 bar 
    codes that have addenda.  Default = Not Required.
    * 5 Digit Addenda  5 Digit Addenda On* 2 Digit Addenda Off 2 Digit Addenda On
    * 5 Digit Addenda Off
    *  Not Required Required 
    						
    							6 - 37
    EAN/JAN 8 Addenda Separator
    When this feature is on, there is a space between the data from the bar code 
    and the data from the addenda.  When turned off, there is no space.  
    Default = On.
    MSI
    
    MSI
    MSI Check Character
    Different types of check characters are used with MSI bar codes.  You can 
    program the scanner to read  MSI bar codes with Type 10 check characters.  
    Default = Validate Type 10, but Don’t Transmit.
    Off *  On
    On
    * Off 
    						
    							6 - 38
    When Check Character is set to Validate and Transmit, the scanner will only 
    read MSI bar codes printed with the specified type check character, and will 
    transmit this character at the end of the scanned data.
    When Check Character is set to Validate, but Don’t Transmit, the unit will only 
    read MSI bar codes printed with the specified type check character, but will not 
    transmit the check character with the scanned data.
    MSI Message Length
    Scan the bar codes below to change the message length.  Refer to Message 
    Lengthon page 6-2 for additional information.  Minimum and Maximum
    lengths = 4-48.   Minimum Default = 4, Maximum Default = 48.
    Plessey Code
    
    Validate Type 10 and Transmit *  Validate Type 10, but Don’t 
    Transmit
    Minimum Message Length
    Maximum Message Length 
    						
    							6 - 39
    Plessey Code
    Plessey Message Length
    Scan the bar codes below to change the message length.  Refer to Message 
    Lengthon page 6-2 for additional information.  Minimum and Maximum
    lengths = 4-48.   Minimum Default = 4, Maximum Default = 48.
    GS1 DataBar Omnidirectional
    < Default All GS1 DataBar Omnidirectional Settings >
    On
    * Off
    Minimum Message Length
    Maximum Message Length 
    						
    							6 - 40
    GS1 DataBar Omnidirectional
    GS1 DataBar Limited
    < Default All GS1 DataBar Limited Settings >
    GS1 DataBar Limited
    GS1 DataBar Expanded
    < Default All GS1 DataBar Expanded Settings >
    * On
    Off
    * On
    Off 
    						
    							6 - 41
    GS1 DataBar Expanded
    GS1 DataBar Expanded Message Length
    Scan the bar codes below to change the message length.  Refer to Message 
    Lengthon page 6-2 for additional information.  Minimum and Maximum
    lengths = 4-74.   Minimum Default = 4, Maximum Default = 74.
    China Post Code
    
    * On
    Off
    Minimum Message Length
    Maximum Message Length 
    						
    							6 - 42
    China Post Code
    China Post Message Length
    Scan the bar codes below to change the message length.  Refer to Message 
    Lengthon page 6-2 for additional information.  Minimum and Maximum
    lengths = 2-80.   Minimum Default = 4, Maximum Default = 80.
    On
    * Off
    Minimum Message Length
    Maximum Message Length 
    						
    							6 - 43
    Korea Post Code
    
    Korea Post Code
    Korea Post Message Length
    Scan the bar codes below to change the message length.  Refer to Message 
    Lengthon page 6-2 for additional information.  Minimum and Maximum
    lengths = 2-80.   Minimum Default = 4, Maximum Default = 48.
    On
    * Off
    Minimum Message Length
    Maximum Message Length 
    						
    							6 - 44
    Codablock F
    
    Codablock F
    Codablock F Message Length
    Scan the bar codes below to change the message length.  Refer to Message 
    Lengthon page 6-2 for additional information.  Minimum and Maximum
    lengths = 1-2048.   Minimum Default = 1, Maximum Default = 2048.
    On
    * Off
    Minimum Message Length
    Maximum Message Length 
    						