Page 311
-. l SBCS CAN FUNCTION AS A STANDALONE COMMUNICATION SYSTEM OR AS A FRONT-END SYSTEM BEHIND OTHER SWITCHING EQUIPMENT, SUCH AS A PABX. . SOME SYSTEM PARAMETER VALUES MAY REQUIRE RESETTING TO ACCOMMODATE CONFIGURATIONS POSSIBLE WITH A FRONT-END ARRANGEMENT. REFER TO CMC-100 TO COORDINATE FEATURE ACCESS NUMBERING PLANS FOR BOTH SYSTEMS AND CMC-200 TO COORDINATE STATION NUMBERING PLANS. 1. USE CMC-250 TO MODIFY TRUNK ASSIGNMENT DATA: . EQUIPMENT NUMBER (Pl) CMC = 250 . TYPE OF TRUNK (P2) Pl: 182...
Page 312
DESCRlPTlOii . ALLOWS SBCS TO BE SHARED BY AS MANY AS FIVE TENANTS. TENANTS MAY USE OWN STATIONS AND/OR TRUNKS, BUT SHARE COMMON CONTROL LOGIC, POWER SUPPLY, ATTENDANT CONSOLE, AND SERVICE TRUNKS. . STATIONS AND TRUNKS (EXCEPT TIE TRUNKS) ARE ASSIGNED TO TENANT NUMBERS SO EACH TENANT CAN ACCESS OWN TRUNKS. TENANTS SHARE SAME FEATURE ACCESS CODE AND STATION NUMBERING PLAN. . THREE TYPES OF TENANT TRUNK SHARING DESIGNATIONS ARE AVAILABLE: - OUTGOING/INCOMING TENANT (NO TRUNK SHARING WITH OTHER...
Page 313
pitEKE- I. USE CMC-20-l TO ASSlGN TENANT NUMBERS TO STATIONS: Q STATION DIRECTORY NUMBER (PI) 8 OPERATION MODE (P2) . TYPE OF DIALING (P3) 8 TENANT NUMBER (P4) CMC = 201 Pl: 236 P4: 2 cl P2: 1 P5: P3: 3 @ METERING GROUP NUMBER FOR SMDR (P5) 2. IF APPLICABLE, USE CMC-102 TO SELECT: . FLAG NUMBER (PI) @ SET VALUE (P2) 3. USE CMC-251 TO ASSIGN TENANT NUMBERS TO TRUNKS: @ EQUIPMENT NUMBER (PI) Pl: 161 P4: 3 . DIAL MODE/BREAK RATIO (P2) @ TRUNK DIRECTORY NUMBER (P3) If ‘I e TENANT NUMBER...
Page 314
Programming Speci System Configurations/ Off-Premises Extension (OPX) I I . ALLOW CONNECTION TO THE SBCS SYSTEM OF SINGLE-LINE TELEPHONE INSTRUMENTS LOCATED AT OFF-PREMISES LOCATION. . CUSTOMER PROVIDED LOOP EXTENDER MUST BE INSTALLED TO EXTEND STATION LINES AND TO PROTECT PUBLIC SWITCHED NETWORK, IF THE IMPEDANCE OF THE PHONE EXCEEDS THE LOOP LIMIT OF THE SYSTEM. . OFF PREMISES EXTENSION (OPX) EQUIPMENT IS MOUNTED AND POWERED EXTERNALLY TO OMNI SBCS CABINET. . RINGING PATTERN FOR OPX STATIONS...
Page 315
e SBCS BEHIND A PAl3X CMC-250 CMC-254 CMC-400 e TENANT ASSIGNMENT CMC-201 CMC-251 CMC-503 8 OFF-PREMISE EXTENSION CMC-200 CMC-204 CMC-102 MODIFY TRUNK ASSIGNMENT DATA MODIFY TRUNK ROUTE TIMING ASSIGNMENT MODIFY TRUNK DIALING ASSIGNMENT ASSIGN TENANT NUMBERS TO STATIONS ASSIGN TENANT NUMBERS TO TRUNKS ASSIGN SMDR OUTPUT FOR TENANTS ASSIGN OPX EQUIPMENT NUMBER TO STATION DIRECTORY NUMBER IDENTIFY DIRECTORY NUMBER AS OPX EXTENSION CHANGE RINGING PATTERN FOR OPX FIXED RINGING 2.200
Page 317
PERFORM THE FOLLOWING PROGRAMMING TASKS IN THE SEQUENCE OUTLINED BELOW USING THE SAMPLE WORK ORDERS AND IN ACCORDANCE WlTH THE GTE OMNll SBCS GTEP MANUAL. COMPLETE THE REVIEW EXERClSE QUESTlONS PERTAINING TO SPECIAL SYSTEM CONFIGURATIONS UPON COMPLETION OF THIS LABORATORY ACTIVITY. WORK ORDER #2.11 :OMPANY NAME: NU SYSTEM CO. PHONE #: (703) 5551212 .OCATION: RESTON, VIRGINIA WORK ORDER #2.11 (TASK #l) )RfGfNATCR: TELECOMMUNICATIONS MANAGER ‘ASKS: s Perform necessary system modifications...
Page 318
Laboratory Activity - Programming WORK ORDER #2.11 :OMPANY NAME: NU SYSTEM CO. PHONE #: (703) 5551212 .OCAT’ON: RESTON, VIRGINIA WORK ORDER H.11 (TASK #2) )R’G’NAToR: TELECOMMUNICATIONS MANAGER .ASKS: e Assign tenant assignments with CMC-201, CMC-102, and CMC-251. (1) Assign stations to tenant numbers with CMC- (1) Perform programming changes for special 201 using the following groups: system configuration. Station DN Tenant Group (2) Check/test the operation of changes after completion of...
Page 319
WORK ORDER #2.11 :OMPANY NAME: NU SYSTEM CO. PHONE #: (703) 5551212 OCATION: RESTON, VIRGINIA WORK ORDER #2.11 (TASK #3) ‘RlGtNATCR: TELECOMMUNICATIONS MANAGER ASKS: --- l Perform programming required for single line station designated-as off-premises extension with CMC-200, CMC-204, and CMC-102. OPX equipment number 027 has (1) Ensure that off-premises SLT instrument and gned to the SLT instrument (directory customer provided loop extender are physically installed. NOTE: Above verification is...
Page 320
Review Exercise - 53 INSTRUCTIONS: THE FOLLOWING EXERCISE CONSISTS OF MULTIPLE CHOICE, TRUE/FALSE, FILL IN THE BLANK, OR MATCHING TYPE QUESTIONS. ALL AVAILABLE RESOURCES (I.E. STUDENT WORKBOOK, NOTES, AND GTEP MANUAL) MAY BE USED AS REFERENCES. SUBMIT EXERCISE TO INSTRUCTOR FOR GRADING WHEN LAST QUESTION HAS BEEN COMPLETED. 1. EXPLAIN WHY IT IS NECESSARY TO EXAMINE TABLES FOR CMC-100 AND CMC-200 WHEN INSTALLING AN OMNI SBCS BEHIND A PABX. 2. HOW WOULD YOU INCREASE THE OMNI SBCS FLASH TIMING VALUE...