GTE Omni Scbs Installation And Maintenance Manual
Here you can view all the pages of manual GTE Omni Scbs Installation And Maintenance Manual. The GTE manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 261
Laboratory Activity - System-Wide Programming Changes (Continued) WORK ORDER #2.7 COMPANY NAME: NU SYSTEM CO. PHONE #: (703) 5551212 LOCATION: RESTON, VIRGINIA WORK ORDER #2.7 (TASK #4) DRlGlNATOR: TELECOMMUNICATIONS MANAGER TASKS: l Modify a system timing parameter with CMC-103. (1) Change the timing value for “call park recall” (1) Perform programming change for system-wide to l/2 minute. (Note: current multiplier is set at 61, yielding a default timing value of 62.464. A multiplier of 88...
Page 262
Laboratory Activity - Systizm-Wide Programming Changes (Continued) GTE OMNn SBCS WORK ORDER #2.7 ZOMPANY NAME: NU SYSTEM CO. PHONE #: (703) 555-1212 -0CATION: RESTON, VIRGINIA WORK ORDER #2.7 (TASK #5) IRlGlNATOR: TELECOMMUNICATIONS MANAGER TASKS: l Modify the default network PAD circuit values with CMC-106. ‘ARAMETERS: INSTRUCTIONS: (1) Reduce the PAD value for outgoing station dial (1) tone with the following parameters: Perform programming change for system-wide function. Incoming...
Page 264
Review Exercise - System-Wide Programming Changes (2.7) INSTRUCTIONS: THE FOLLOWING EXERCISE CONSISTS OF MULTIPLE CHOICE, TRUE/FALSE, FILL IN THE BLANK, OR MATCHING TYPE QUESTIONS. ALL AVAILABLE RESOURCES (I.E., STUDENT WORKBOOK, NOTES, AND GTEP MANUAL) MAY BE USED AS REFERENCES. SUBMIT EXERCISE TO INSTRUCTOR FOR GRADING WHEN LAST QUESTION HAS BEEN COMPLETED. 1. THE DEFAULT FEATURE NUMBER (FNO) FOR GROUP PICKUP IS AND DEFAULT FEATURE ACCESS CODE IS . 2. FEATURE ACCESS CODES MAY BE COMPOSED OF A...
Page 265
Review Exercise - System-Wide Programming Changes (2,7) (Continued) 8. HOW IS TIMING CALCULATED FOR SYSTEM TIMING VALUES? 9. WHAT MULTIPLIER VALUE WOULD YOU USE TO CHANGE THE CALL ANNOUNCE WARNING BURST TO ONE SECOND? IO. WHAT MULTIPLIER VALUE WOULD YOU USE TO CHANGE THE DSS CAMP-ON RECALL TIMING TO 1% MINUTES? 11. WHEN MIGHT IT BE NECESSARY TO CHANGE THE DEFAULT PAD CIRCUIT VALUES? 12. STATION USERS HAVE COMPLAINED THAT THE BUSY TONE IS TOO LOUD. WHAT PARAMETERS NEED CHANGING WITH CMC-106 TO...
Page 268
2.8 Emablinq Obiective GIVEN: . l l 0 0 0 ACTION: . 0 CRITERIA: @ l GTE OMNI SBCS GTE OMNI SBCS Peripherals PORTABLE MAINTENANCE PANEL GTE OMNI SBCS COURSE AND SITE DOCUMENTATION PACKAGE LABORATORY ACTIVITY - PROGRAMMING STATION MESSAGE DETAIL RECORDER REVIEW EXERCISE USE OMNI SBCS PROGRAMMING TOOLS AND EQUIPMENT TO: - INSTALL STATION MESSAGE DETAIL RECORDER AND ASSIGN CALL SCREENING OPTIONS. COMPLETE REVIEW EXERCISE. DEMONSTRATION OF ABOVE TASKS IN ACCORDANCE WITH PRO- CEDURES...
Page 269
- Programming Station Message Detail Recorder/SM creening GTE OMN~ SBCS 1 DESCRIPTION 1 l PROVIDES LOCAL PRINTOUT OF SYSTEM CALL INFORMATION. . IF SMDR OPTION IS INSTALLED THE FOLLOWING INFORMATION IS RECORDED FOR EVERY CALL: - TIME OF CALL ORIGINATION - CALL DURATION RECORDED IN HOURS, MINUTES, AND SECONDS - ORIGINATING STATION NUMBER - TRUNK NUMBER WITH IDENTIFICATION - CALLING PARTY IDENTIFICATION - TRUNK ACCESS CODE - DIRECTORY NUMBER DIALED AND PERSONAL ACCOUNTING CODE (SVR 1.5.X.X)...
Page 270
1 PROCEDURE * 1 1. USE CMC-500 TO ASSIGN SMDR OUTPUT OPTIONS ON OUTGOING CONNECTION: . CO OUTGOING CONNECTION (PI) CMC=500 . TIE LINE OUTGOING CONNECTION (P2) n PI: 1 P4: 1 . ACCOUNT FLAG (P3) P2: 0 . TOLL CALL FLAG (P4) P3: 0 2. USE CMC-501 TO ASSIGN TRUNK GROUPS FOR SMDR OUTPUT: CMC=501 I I Pl: 13 . TRUNK GROUP NUMBER (PI)** P2: 1 . OUTPUT IDENTIFICATION FLAG (P2) 3. USE CMC-502 TO ASSIGN COR FOR StiDR OUTPUT: . CLASS OF RESTRICTION (PI) . OUTPUT IDENTIFICATION FLAG (P2) 4. USE...