Home > GTE > Communications System > GTE Omni Scbs Installation And Maintenance Manual

GTE Omni Scbs Installation And Maintenance Manual

Here you can view all the pages of manual GTE Omni Scbs Installation And Maintenance Manual. The GTE manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 251

,,-. 
Systemwide Programming Changes/ 
ering Plan Assignment 
Gull 
1 DESCRIPTION 1 
@ DEFAULT STANDARD SYSTEM NUMBERING PLAN DEFINING FEATURE NUMBERS, 
FEATURE ACCESS CODES, TRUNK GROUP NUMBERS, AND SEND AND SAVE/SEND 
AS DIALED FOR TIE LINES. 
I PROCEDURE I * 
IDENTIFY FEATURE ACCESS CODES TO BE CHANGED USING DEFAULT STANDARD 
TABLE. 
1. USE CMC-100 TO CHANGE: 
- FEATURE NUMBER (PI) 
- FEATURE ACCESS CODE (P2) 
- TRUNK GROUP NUMBER (P3) 
- OUTGOING DIRECTORY NUMBER (P4) 
- ACCESS CODE DIGITS TO BE SENT...

Page 252

Systemwide Progra 
Parameter Assignment 
1 DESCRIPTION 1 
. ALLOWS FLAGS TO BE SET FOR THE FOLLOWING SERVICE FUNCTIONS: 
- A CHECK FOR TRUNK-TO-TRUNK TRANSFER RESTRICTION. 
- INDICATION OF WHETHER A WARNING BURST (TONE) INTERRUPTS USERS 
WHEN EXECUTIVE OVERRIDE FEATURE IS ACTIVATED. 
- DESIGNATION OF VOICE OR TONE OPTION WHEN CALL ANNOUNCE 
INTERCOM FEATURE IS ACTIVATED. 
@ WHILE DEFAULT SYSTEM CAPACITY FOR SYSTEM FLAGS IS 32, ONLY 3 FLAGS (AS 
DEFINED ABOVE) CAN BE USED AT THE PRESENT TIME. REMAINING...

Page 253

1 DESCRIPTION 1 Gull aimnn SBCS 
@ ALLQWS CHANGE OF TI ING PARAMETERS FOR VARIOUS SYSTEM FUNCTIONS. 
ACTUAL TIMING FOR EACH TIMING PARAMETER IS CALCULATED BY MULTIPLYING 
THE TIMING PARAMETER’S DESIGNATED FIXED UNIT BY A MULTIPLER VALUE (0 TO 
255). 
EXAMPLE: 
FOR DSS CAMP-ON RECALL (PARAMETER I), FIXED TIMING UNIT IS 1024 ms. THE 
DEFAULT MULTIPLIER (PARAMETER 2) IS 31: 
1024 ms X 31 = 31.1744 SECONDS 
TO INCREASE TIME TO APPROXIMATELY ONE MINUTE, CHANGE VALUE FOR 
PARAMETER 2 TQ 60: 
1024 ms X 60 =...

Page 254

Systemwide Pr ming Changes/System 
Parameter Assignment 
GTE alMm!i SBCS 
( 
. ALLOWS UP TO 26 FLAGS TO BE SET FOR VARIOUS SYSTEM FUNCTIONS. 
1 PROCEDURE I* 
1. USE CMC-102 TO ADD/CHANGE: 
- FLAG NUMBER (PI) 
- SET FLAG VALUE (P2) 
CMC=lO2 
n 
Pl: 6 
P2: 1 
* SEE CMC TABLE IN OMNI SBCS GTEP MANUAL, FOR A LISTING OF FLAG 
NUMBERS AND APPROPRIATE SETTING OF PARAMETER VALUES. 
REFER TO CMC TABLE IN OMNI SBCS GTEP MANUAL WHEN CHANGING FLAG 
NUMBER 5 (SIGNALING CHECK FOR TRUNK TO TRUNK CONNECTION...

Page 255

stem-wide Programming Changes/ 
Network L Ian Assignment 
[ DESCRIPTION 1 
e ALLOWS CHANGE IN DIGITAL PAD CIRCUIT (PAD) VALUE TO IMPROVE QUALITY OF 
INCOMING OR OUTGOING CONNECTIONS. 
1 PROCEDURE I* 
DETERMINE WHICH INCOMING OR OUTGOING ROUTES ARE AFFECTED BY CIRCUIT 
LOSS QUALITY. IDENTIFY SPECIFIC CIRCUITS THAT ARE EXPERIENCING CIRCUIT LOSS. 
1. USE CMC-106 TO CHANGE VALUE OF DIGITAL PAD: 
- INCOMING ROUTE (PI) 
CMC=lO6 
- OUTGOING ROUTE (P2) 
r-l Pl: 2 
- VALUE OF DIGITAL PADDING CIRCUIT (P3) P2: 5...

Page 256

System-Wide Programming Changes/ 
Trunk Route Timins 
@ SETS TRUNK ROUTE TIMING PARAMETER FOR VARIOUS SYSTEM TRUNK 
ROUTES 
l TIMING IS CALCULATED BY MULTIPLYING THE TRUNK’S FIXED TIMING UNIT (IN ms) 
BY A DESIGNATED MULTIPLER. 
[PROCEDUREI 
1. USE CMC-254 TO ASSIGN: 
CMC=254 
Pl: 13 
. TRUNK GROUP NUMBER (PI) 
. ROUTE TIMING ID NUMBER (P2) 
. NORMALIZED TIMING/MULTIPLIER (P3) 
0 P2: 1 
P3: 14 
* REFER TO CMC TABLE IN OMNI SBCS GTEP MANUAL FOR DESCRIPTIONS OF 
AVAILABLE ROUTE TIMING AND MULTIPLIER FOR...

Page 257

System-wide Programming Change&MC 
and Summary 
CATEGORY 
. NUMBERING PLAN ASSIGNMENT 
. SERVICE PARAMETER ASSIGNMENT 
l SYSTEM PARAMETERS ASSIGNMENT 
. SYSTEM TIMING PARAMETER 
ASSIGNMENT 
. NETWORK LOSS (PAD) CONTROL 
@ TRUNK ROUTE TIMING 
CMC TABLE 
CMC-100 
CMC-101 
CMC-102 
CMC-103 
CMC-106 
CMC-254 
FUNCTION 
DEFINES DEFAULT STANDARD 
SYSTEM NUMBERING PLAN 
(FEATURE NUMBERS, FEATURE 
ACCESS CODES, TRUNK GROUP 
NUMBERS, ETC.) 
DEFINES SYSTEM SERVICE 
FUNCTION PARAMETERS. 
DEFINES SYSTEM FUNCTION...

Page 258

PERFORM THE FOLLOWING PROGRAMMING TASKS IN THE SEQUENCE OUTLINED BELOW USING THE 
SAMPLE WORK ORDERS AND IN ACCORDANCE WITH THE GTE QMNI SBCS GTEP MANUAL. COMPLETE 
THE REVIEW EXERCISE QUESTIONS PERTAINING TO SYSTEM-WIDE PROGRAMMING CHANGES UPON 
COMPLETION OF THIS LABORATORY ACTIVITY. 
WORK ORDER #2.7 
:OMPANY NAME: NU SYSTEM CO. 
PHONE ?+: (703) 555-1212 
CCAT’CN: RESTON, VIRGINIA WORK ORDER # 2.7 (TASK #l) 
)R’G’NATCR: TELECOMMUNICATIONS MANAGER 
ASKS: 
e Modify default standard numbering plan with...

Page 259

-_ 
WORK ORDER #2.7 
:OMPANY NAME: NU SYSTEM CC. PHONE #: (703) 5551212 
.QCATION: RESTON, VIRGINIA WORK ORDER #2.7 (TASK #2) 
)RfGINATOR: TELECOMMUNICATIONS MANAGER 
‘ASKS: 
l Change a service parameter flag with CMC-101. 
(1) Change the flag indicating whether a warning (1) Perform programming changes for system- 
burst is heard during executive override, to 
wide function. 
“send burst”. 
(2) Check/test the operation of changes after 
completion of this portion of the laboratory 
(3) Proceed to the...

Page 260

Laboratory Activity 
- System-Wide 
Programming Changes (Continued) 
GTE awn SBm 
WORK ORDER #2.7 
COMPANY NAME: NU SYSTEM CO. 
LOCATION: RESTON, VIRGINIA 
DRIGINATOR: TELECOMMUNICATIONS MANAGER PHONE #: (703) 555-1212 
WORK ORDER #2.7 (TASK #3) 
TASKS: 
l Change a system parameter flag with CMC-102. 
PARAMETERS: INSTRUCTIONS: 
(1) Change the flag indicating the type of ringing 
pattern for off-premises extensions to “recall 
ringing.” 
NOTE: 
Programming off-premises extensions will be 
addressed in...
Start reading GTE Omni Scbs Installation And Maintenance Manual

Related Manuals for GTE Omni Scbs Installation And Maintenance Manual

All GTE manuals