Measurement and Calculation Setup
LOGIQ 5 Basic User Manual 7-31
Direction 2300002-100 Rev. 2
Removing items from the Touch Panel
To remove items from the Touch Panel, you remove them from 
the Measure & Study list.
1. Move the Trackball to highlight the item in the Measure & 
Study list and press Set. 
2.  Select the X to the right of the list.
The system removes the item from the Measure & Study list 
and from the Touch Panel. The item is still listed in the 
Available folders and measurements list....

Page 282

General Measurements and Calculations
7-32 LOGIQ 5 Basic User Manual
Direction 2300002-100 Rev. 2
Removing items from the Touch Panel (continued)
To remove an item from the Selection menu:
1. Move the Trackball to the item in the Available folders and 
measurements list.
2.  To clear the check box for the item, move the Trackball to 
the check box and press Set.
The system removes the item from the Selection menu, the 
Measure & Study list, and from the Touch Panel. It is also 
not listed in the Summary...

Page 283

Measurement and Calculation Setup
LOGIQ 5 Basic User Manual 7-33
Direction 2300002-100 Rev. 2
Setting up an automatic exam flow
In some cases, related measurements are put in a 
measurement folder. This allows you to logically organize 
measurements. It also allows you to specify that the system 
automatically start each measurement in a folder, one after the 
other. This is the automatic sequence feature. To use this 
feature:
1.  In the Selection menu, select the folder that contains the 
measurements...

Page 284

General Measurements and Calculations
7-34 LOGIQ 5 Basic User Manual
Direction 2300002-100 Rev. 2
Changing Measurements
You can make changes to some of the measurements. For 
example, Head Circumference can be measured with an ellipse, 
a trace, or two distances. You can specify which measurement 
type you want the system to use as the default. You specify the 
measurement type by selecting the tool to use to make the 
measurement.
•  To change the tool used to make a measurement:
In the Measurement...

Page 285

Measurement and Calculation Setup
LOGIQ 5 Basic User Manual 7-35
Direction 2300002-100 Rev. 2
Changing Measurements (continued)
 Figure 7-20. Measurement & Analysis screen: Change measurements 

Page 286

General Measurements and Calculations
7-36 LOGIQ 5 Basic User Manual
Direction 2300002-100 Rev. 2
Adding Folders and Measurements
Adding a folder
When you add a folder, it can be a study, or a measurement 
folder that includes related measurements. 
1.  In the Selection menu, select the study or folder where you 
want to add the folder.
2.  In the Measurement menu section, select Add folder.
•  If you select Blank, the system adds a folder with a 
name such as USERDEFS1. It is listed in the Selection...

Page 287

Measurement and Calculation Setup
LOGIQ 5 Basic User Manual 7-37
Direction 2300002-100 Rev. 2
Adding a folder (continued)
 Figure 7-22. Measurement & Analysis: Add folder 

Page 288

General Measurements and Calculations
7-38 LOGIQ 5 Basic User Manual
Direction 2300002-100 Rev. 2
Adding a user-defined measurement
You can create a user-defined measurement in a system-
defined folder or in a folder you created.
1.  In the Selection menu, select the study or folder where you 
want to add the measurement.
2.  In the Measurement menu section, select Add 
measurement.
The system displays the Add Measurement window. See 
Figure 7-24. 
 Figure 7-23. Add Measurement window
3.  Do one of the...

Page 289

Measurement and Calculation Setup
LOGIQ 5 Basic User Manual 7-39
Direction 2300002-100 Rev. 2
Adding a user-defined measurement (continued)
4. Select OK.
•  If you created a blank measurement, the system adds a 
measurement with a name such as USERDEFM3. 
•  If you created a measurement from a copy of an existing 
measurement, the system lists the measurement and its 
parameters in the Measurement section.
5.  When you create a new measurement, the measurement 
name is automatically highlighted. Type a...

Page 290

General Measurements and Calculations
7-40 LOGIQ 5 Basic User Manual
Direction 2300002-100 Rev. 2
Adding a user-defined measurement (continued)
Defining
measurement
parametersAfter you add a measurement, you can add parameters. You 
may also want to change parameters if you copied an existing 
measurement. See ‘Changing or adding measurement 
parameters’ for more information.
Changing or adding measurement parameters
You can make changes to measurement parameters and you 
can add measurement parameters....