Page 91

EPSON Stylus Photo R1900/R2880/R2000Revision EDisassembly And Assembly Disassembling the Printer Mechanism 91
Confidential
5. Remove the coil section of Torsion Spring 24.7 from the tab on the Left CR Shaft 
Mounting Plate with tweezers.
Figure 4-45. Removing the Torsion Spring 24.7 (1)
6. Remove Torsion Spring 24.7 from the CR Scale by the following procedure:
6-1. Stand the coil section.
6-2. Lower the coil section downwards to remove Foot 1 from the notch on the 
Left CR Shaft Mounting Plate.
6-3....

Page 92

EPSON Stylus Photo R1900/R2880/R2000Revision EDisassembly And Assembly Disassembling the Printer Mechanism 92
Confidential
4.4.3  Printhead / CSIC Assy1.Remove the Upper Housing / Printer Cover. (p.81)
2. Release the Carriage Lock, and move the Carriage Unit to the center. 
(Refer to 4.1.6 Locking/Unlocking the Carriage and Opening/Closing the CDR 
Tray Base (p.73))
3. Open the Ink Cartridge Cover.
4. Cut the Hinge, Cover Cartridge with a nipper or a similar tool and remove the 
upper part of the Hinge,...

Page 93

EPSON Stylus Photo R1900/R2880/R2000Revision EDisassembly And Assembly Disassembling the Printer Mechanism 93
Confidential
7. Disengage the two hooks that secure the Ink Guide and remove the Ink Guide from 
the Cartridge Unit.
Figure 4-54. Removing the Ink Guide



The Hinge, Cover Cartridge can not be removed without damaging 
it. Whenever replacing the Printhead, the Hinge, Cover Cartridge 
must be also replaced with a new one. 
Figure 4-52. Hinge, Cover CartridgeEngage the two dowels of the...

Page 94

EPSON Stylus Photo R1900/R2880/R2000Revision EDisassembly And Assembly Disassembling the Printer Mechanism 94
Confidential
8. Peel off a piece of acetate tape and disconnect the CSIC FFC from the connector 
on the CSIC Board. 
9. Disengage the Cable Holder from the hook and remove it.
Figure 4-55. Removing the CSIC Assy (1)10. Using the special tool (see p.71) disengage the two hooks of the CSIC Assy on the 
right and left on the rear of the Carriage Unit and remove the CSIC Assy upward.
Figure 4-56....

Page 95

EPSON Stylus Photo R1900/R2880/R2000Revision EDisassembly And Assembly Disassembling the Printer Mechanism 95
Confidential
11. Remove the three C.B.P. M2.6 x 8 that secure the Printhead using the Phillips 
Screw Driver, No.1, and vertically lift the Printhead to remove it.
Figure 4-57. Removing the Printhead
12. Remove the two Head FFCs from the Printhead.
Figure 4-58. Remove the Head FFC
7) C.B.P. M2.6x8
(3±0.5 kgf.cm)
1
23
Head
Printhead 
Head FFCs
Confirm that the pad is attached at the position in...

Page 96

EPSON Stylus Photo R1900/R2880/R2000Revision EDisassembly And Assembly Disassembling the Printer Mechanism 96
Confidential
4.4.4  Lower Housing / Printer Mechanism1.Remove the Upper Housing / Printer Cover. (p.81)
2. Disconnect the PictBridge cable from connector CN1 on the Main Board.
3. Disconnect the High Voltage Module cable from connector CN25 on the Main 
Board. 
Figure 4-61. Removing the Lower Housing and Printer Mechanism
4. Grip both ends of the two Ink Tube Fasteners with your fingers, slide...

Page 97

EPSON Stylus Photo R1900/R2880/R2000Revision EDisassembly And Assembly Disassembling the Printer Mechanism 97
Confidential
8. Lift the Printer Mechanism grasping it by the holding positions with your hands, 
and remove it from the Lower Housing.
When performing the following step, make sure to grasp the Printer 
Mechanism by the specified positions shown below. Otherwise, the 
frames may become deformed.
Figure 4-63. Handling the Printer MechanismInsert the Waste Ink Tube as shown in the figure...

Page 98

EPSON Stylus Photo R1900/R2880/R2000Revision EDisassembly And Assembly Disassembling the Printer Mechanism 98
Confidential
4.4.5  Carriage Shaft / Carriage Unit1.Remove the Printhead / CSIC Assy. (p.92)
2.Remove the CR Scale. (p.90)
3.Remove the LED Board. (p.86)
4.Remove the APG Assy. (p.89)
5. Rotate the PG Cam (Right) to adjust its positions other than PG++ downside.
Figure 4-67. Adjusting the PG Cam
Attach the Label, Ink Position;B at the position in the figure 
below.
Figure 4-66. Attaching the...

Page 99

EPSON Stylus Photo R1900/R2880/R2000Revision EDisassembly And Assembly Disassembling the Printer Mechanism 99
Confidential
6. Remove the two C.B.S. M3 x 6 screws that secure the Frame Support Plate (Left), 
and remove it.
Figure 4-68. Removing the Left Frame Support Plate7. Remove the foot of Left PG Torsion Spring from tab A, and remove the coil 
section from tab B to remove Left PG Torsion Spring from the Main Frame.
Figure 4-69. Removing the Left PG Torsion Spring
8. Remove the foot of Right PG...

Page 100

EPSON Stylus Photo R1900/R2880/R2000Revision EDisassembly And Assembly Disassembling the Printer Mechanism 100
Confidential
9. Remove CR Shaft Mounting Plate Fixed Spring from the tab and notch on the 
Main Frame, and pull out the spring in the direction of the arrow.
Figure 4-72. Removing CR Shaft Mounting Plate Fixed Spring10. Remove the extension spring for the Driven Pulley Holder from the Main Frame 
and the tab on the Drive Pulley Holder with needle-nose pliers.
Figure 4-73. Removing the Extension...