Page 91
EPSON Stylus Photo R1900/R2880/R2000Revision EDisassembly And Assembly Disassembling the Printer Mechanism 91 Confidential 5. Remove the coil section of Torsion Spring 24.7 from the tab on the Left CR Shaft Mounting Plate with tweezers. Figure 4-45. Removing the Torsion Spring 24.7 (1) 6. Remove Torsion Spring 24.7 from the CR Scale by the following procedure: 6-1. Stand the coil section. 6-2. Lower the coil section downwards to remove Foot 1 from the notch on the Left CR Shaft Mounting Plate. 6-3....
Page 92
EPSON Stylus Photo R1900/R2880/R2000Revision EDisassembly And Assembly Disassembling the Printer Mechanism 92 Confidential 4.4.3 Printhead / CSIC Assy1.Remove the Upper Housing / Printer Cover. (p.81) 2. Release the Carriage Lock, and move the Carriage Unit to the center. (Refer to 4.1.6 Locking/Unlocking the Carriage and Opening/Closing the CDR Tray Base (p.73)) 3. Open the Ink Cartridge Cover. 4. Cut the Hinge, Cover Cartridge with a nipper or a similar tool and remove the upper part of the Hinge,...
Page 93
EPSON Stylus Photo R1900/R2880/R2000Revision EDisassembly And Assembly Disassembling the Printer Mechanism 93 Confidential 7. Disengage the two hooks that secure the Ink Guide and remove the Ink Guide from the Cartridge Unit. Figure 4-54. Removing the Ink Guide The Hinge, Cover Cartridge can not be removed without damaging it. Whenever replacing the Printhead, the Hinge, Cover Cartridge must be also replaced with a new one. Figure 4-52. Hinge, Cover CartridgeEngage the two dowels of the...
Page 94
EPSON Stylus Photo R1900/R2880/R2000Revision EDisassembly And Assembly Disassembling the Printer Mechanism 94 Confidential 8. Peel off a piece of acetate tape and disconnect the CSIC FFC from the connector on the CSIC Board. 9. Disengage the Cable Holder from the hook and remove it. Figure 4-55. Removing the CSIC Assy (1)10. Using the special tool (see p.71) disengage the two hooks of the CSIC Assy on the right and left on the rear of the Carriage Unit and remove the CSIC Assy upward. Figure 4-56....
Page 95
EPSON Stylus Photo R1900/R2880/R2000Revision EDisassembly And Assembly Disassembling the Printer Mechanism 95 Confidential 11. Remove the three C.B.P. M2.6 x 8 that secure the Printhead using the Phillips Screw Driver, No.1, and vertically lift the Printhead to remove it. Figure 4-57. Removing the Printhead 12. Remove the two Head FFCs from the Printhead. Figure 4-58. Remove the Head FFC 7) C.B.P. M2.6x8 (3±0.5 kgf.cm) 1 23 Head Printhead Head FFCs Confirm that the pad is attached at the position in...
Page 96
EPSON Stylus Photo R1900/R2880/R2000Revision EDisassembly And Assembly Disassembling the Printer Mechanism 96 Confidential 4.4.4 Lower Housing / Printer Mechanism1.Remove the Upper Housing / Printer Cover. (p.81) 2. Disconnect the PictBridge cable from connector CN1 on the Main Board. 3. Disconnect the High Voltage Module cable from connector CN25 on the Main Board. Figure 4-61. Removing the Lower Housing and Printer Mechanism 4. Grip both ends of the two Ink Tube Fasteners with your fingers, slide...
Page 97
EPSON Stylus Photo R1900/R2880/R2000Revision EDisassembly And Assembly Disassembling the Printer Mechanism 97 Confidential 8. Lift the Printer Mechanism grasping it by the holding positions with your hands, and remove it from the Lower Housing. When performing the following step, make sure to grasp the Printer Mechanism by the specified positions shown below. Otherwise, the frames may become deformed. Figure 4-63. Handling the Printer MechanismInsert the Waste Ink Tube as shown in the figure...
Page 98
EPSON Stylus Photo R1900/R2880/R2000Revision EDisassembly And Assembly Disassembling the Printer Mechanism 98 Confidential 4.4.5 Carriage Shaft / Carriage Unit1.Remove the Printhead / CSIC Assy. (p.92) 2.Remove the CR Scale. (p.90) 3.Remove the LED Board. (p.86) 4.Remove the APG Assy. (p.89) 5. Rotate the PG Cam (Right) to adjust its positions other than PG++ downside. Figure 4-67. Adjusting the PG Cam Attach the Label, Ink Position;B at the position in the figure below. Figure 4-66. Attaching the...
Page 99
EPSON Stylus Photo R1900/R2880/R2000Revision EDisassembly And Assembly Disassembling the Printer Mechanism 99 Confidential 6. Remove the two C.B.S. M3 x 6 screws that secure the Frame Support Plate (Left), and remove it. Figure 4-68. Removing the Left Frame Support Plate7. Remove the foot of Left PG Torsion Spring from tab A, and remove the coil section from tab B to remove Left PG Torsion Spring from the Main Frame. Figure 4-69. Removing the Left PG Torsion Spring 8. Remove the foot of Right PG...
Page 100
EPSON Stylus Photo R1900/R2880/R2000Revision EDisassembly And Assembly Disassembling the Printer Mechanism 100 Confidential 9. Remove CR Shaft Mounting Plate Fixed Spring from the tab and notch on the Main Frame, and pull out the spring in the direction of the arrow. Figure 4-72. Removing CR Shaft Mounting Plate Fixed Spring10. Remove the extension spring for the Driven Pulley Holder from the Main Frame and the tab on the Drive Pulley Holder with needle-nose pliers. Figure 4-73. Removing the Extension...