3. Pull the air filter out of the projector. Note: Air filters contain polypropylene. Dispose of used air filters according to local regulations. 191
4. Place the new air filter in the projector as shown. 192
5. Close the air filter cover and slide the latch. Parent topic: Air Filter and Vent Maintenance 193
Projector Lamp Maintenance The projector keeps track of the number of hours the lamp is used and displays this information in the projectors menu system. Replace the lamp as soon as possible when the following occurs: • The projected image gets darker or starts to deteriorate • A message appears when you turn on the projector telling you to replace the lamp • The projectors lamp light is flashing orange and its power light is flashing blue Replacing the Lamp Resetting the Lamp Timer Parent topic:Projector Maintenance Related references Optional Equipment and Replacement Parts Projector Lamp Specifications Projector Information Display - Info Menu Replacing the Lamp Before you replace the lamp, let the projector cool down for at least one hour so the lamp will not be hot. Warning:Let the lamp fully cool before replacing it to avoid injury. You can replace the lamp while the projector is mounted on the wall or ceiling. 1. Turn off the projector and unplug the power cord. 2. Allow the projector lamp to cool down for at least one hour. Warning: If the lamp is broken, glass fragments may be loose inside the lamp chamber. Be careful removing any broken glass to avoid injury. If the projector is mounted on the wall or ceiling, stand to the side in case the lamp is broken. 194
3. Use the screwdriver included with the replacement lamp to loosen the screw securing the lamp cover. 4. Slide off the lamp cover. 195
5. Loosen the screws securing the lamp to the projector. The screws do not come all the way out. 6. Lift up the lamp handle and gently pull the lamp out of the projector. Note: The lamp(s) in this product contain mercury. Please consult your state and local regulations regarding disposal or recycling. Do not put in the trash. 196
7. Gently insert the new lamp into the projector along the guide rail. If it does not fit easily, make sure it is facing the right way. Press the handle down. Caution: Do not touch any glass on the lamp assembly to avoid premature lamp failure. 8. Tighten the screws to secure the lamp. 197
9. Replace the lamp cover and tighten the screw to secure it. Note: Be sure the lamp cover is securely installed or the lamp will not come on. Reset the lamp timer to zero to keep track of the new lamp’s usage. Parent topic: Projector Lamp Maintenance Related tasks Resetting the Lamp Timer Resetting the Lamp Timer You must reset the lamp timer after replacing the projectors lamp to clear the lamp replacement message and to keep track of lamp usage correctly. Note:Do not reset the lamp timer if you have not replaced the lamp to avoid inaccurate lamp usage information. 1. Turn on the projector. 2. Press the Menubutton. 198
3. Select the Resetmenu and press Enter. 4. Select Reset Lamp Hours and pressEnter. You see a prompt asking if you want to reset the lamp hours. 5. Select Yesand press Enter. 6. Press MenuorEsc to exit the menus. Parent topic: Projector Lamp Maintenance Related tasks Replacing the Lamp Replacing the Remote Control Batteries The remote control uses two AA manganese or alkaline batteries. Replace the batteries as soon as they run out. Caution:Use only the type of batteries specified in this manual. Do not install batteries of different types, or mix new and old batteries. 199
1. Open the battery cover as shown. 2. Remove the old batteries. Warning: If the battery fluid has leaked, wipe it away with a soft cloth and avoid getting the fluid on your hands. If it gets on your hands, wash them immediately to avoid injury. 3. Insert the batteries with the +and –ends facing as shown. 200