2478 - xx Advanced VGA BitBLT test. 2480 - xx Advanced VGA Linedraw test. =========================================================================== Table 2-12. Audio Computer Checkup Error Codes =========================================================================== Error Code Description Recommended Action =========================================================================== 3206 - xx Audio system internal Replace the system board. error. =========================================================================== Table 2-13. Network Controller Computer Checkup Error Codes =========================================================================== Error Code Description Recommended Action =========================================================================== 6000 - xx Error occurred while 1. Run the ISA setup utility, attempting to identify reconfigure the failing network a particular network controller, and retest. interface controller. 2. Ensure that the network controller is seated properly, if applicable. 3. Remove any cables attached to the network controller(s) and retest. 4. Ensure that any jumpers or DIP switches on the controller board are set to the correct positions. (Refer to the hardware documentation for more information.) 5. If the network controller is a stand-alone board, replace the board. 6. If the network controller is integrated into the expansion base system board, replace the expansion base system board. 7. If using multiple network controller boards, attempt to locate the defective board by completing the following steps: a. Remove all network controller boards. b. Install one network controller board. c. Retest with Computer Checkup. d. Keep adding the boards one at a time and retesting until the defective board is located. --------------------------------------------------------------------------- 6001 - xx Network card setup The following steps apply to failed. 6001 - xx and 6002 - xx error codes:
6002 - xx Network card transmit failed. 1. Check interrupt type and number setting. 2. Check media connection at controller and MAU *. 3. Check media speed (4/16) and type (UTP/STP **) settings. 4. Check MAU, cabling, or other network components. 5. Replace controller. =========================================================================== Error Code Description Recommended Action =========================================================================== 6014 - xx Ethernet configuration The following steps apply to test failed. 6014 - xx and 6016 - xx error codes: 6016 - xx Ethernet reset test failed. 1. Run the ISA setup utility, reconfigure the failing network controller, and retest. 2. Ensure that the network controller is seated properly, if applicable. 3. Replace the network controller. --------------------------------------------------------------------------- 6028 - xx Ethernet internal The following steps apply to loopback test failed. 6028 - xx and 6029 - xx error codes: 6029 - xx Ethernet external loopback test failed. 1. If using external loopback plug(s), check that the correct type of loopback plug is being used. 2. If using external loopback plugs, check that loopback plug is connected to the correct media connector at the rear of the computer. 3. If using a live network for this test, ensure that the network, concentrators, and cables are functional. 4. Run the ISA setup utility, reconfigure the failing network controller, and retest. 5. Ensure that any jumpers or DIP switches on the controller board are set to the correct positions. (Refer to the hardware documentation for more information.) 6. If the network controller is a stand-alone board, replace the board. 7. If the network controller is integrated into the expansion base system board, replace the expansion base system board. 8. If using multiple network controller boards, attempt to
locate the defective board by completing the following steps: a. Remove all network controller boards. b. Install one network controller board. c. Retest with Computer Checkup. d. Keep adding boards and retesting (repeating steps b and c) until the defective board is located. =========================================================================== Error Code Description Recommended Action =========================================================================== 6054 - xx Token Ring The following steps apply to configuration test 6054 - xx and 6056 - xx error failed. codes: 6056 - xx Token Ring reset test failed. 1. Run the ISA setup utility, reconfigure the failing network controller, and retest. 2. Ensure that the network controller is seated properly, if applicable. 3. Replace the network controller. --------------------------------------------------------------------------- 6068 - xx Token Ring internal Refer to recommended actions for loopback test failed. Error Code 6028 - xx. --------------------------------------------------------------------------- 6069 - xx Token Ring external Refer to recommended actions for loopback test failed. Error Code 6029 - xx. --------------------------------------------------------------------------- 6089 - xx Token Ring open. Refer to recommended actions for Error Code 6029 - xx. --------------------------------------------------------------------------- * MAU = Multi-station Access Unit ** UTP/STP = Unshielded Twisted Pair/Shielded Twisted Pair =========================================================================== SCSI Computer Checkup Error Codes The SCSI Computer Checkup error codes and messages in Table 2-14 are divided into three parts: o Table 2-14A (SCSI Device Names) o Table 2-14B (SCSI Test Names) o Table 2-14C (SCSI Test Error Codes) SCSI error messages contain six digits and begin with the two-digit number 65, 66, or 67, which indicates the drive type being tested (Table 2-14A). The second two-digit number indicates the type of operation being tested on the drive (Table 2-14B). The last two-digit number indicates the specific error (Table 2-14C).
For example, with error code 6523-05, the first two-digit number of the error code (65) indicates a disk problem (Table 2-14A). The second two-digit number (23) indicates a random read (Table 2-14B). The last two-digit number (05) indicates a seek failure (Table 2-14C). Thus, in this example, the diagnostics program tested the random read functioning of the hard drive and received a seek failure. The drive is faulty and must be replaced. NOTE: Refer to Chapter 7 for SCSI troubleshooting information. Table 2-14A. SCSI Computer Checkup Error Codes - SCSI Device Names =========================================================================== Error Code Description =========================================================================== 65xx - xx Disk 66xx - xx CD 67xx - xx Tape =========================================================================== Table 2-14B. SCSI Computer Checkup Error Codes - SCSI Test Names =========================================================================== Error Code Description =========================================================================== xx00 - xx ID xx05 - xx Read xx06 - xx SA/Media xx23 - xx Random Read =========================================================================== Table 2-14C. SCSI Computer Checkup Error Codes - SCSI Test Error Codes =========================================================================== Error Code Description Recommended Action =========================================================================== xxxx - 02 Drive not installed. Check cable connections. --------------------------------------------------------------------------- xxxx - 03 Media not in drive. Check for and install DATA CD or write-enabled tape in drive. --------------------------------------------------------------------------- xxxx - 05 Seek failure. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 06 Drive timed out. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 07 Drive busy. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 08 Drive already reserved. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 11 Media soft error. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 12 Drive not ready. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 13 Media error. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 14 Drive hardware error. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 15 Illegal drive command. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 16 Media was changed. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 17 Tape write protected. 1. Disable write protect on
tape cartridge. 2. Replace tape drive. --------------------------------------------------------------------------- xxxx - 18 No data detected. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 21 Drive command aborted. Replace the indicated device. --------------------------------------------------------------------------- 65xx - 24 Media hard error. 1. Back up data and perform Surface Analysis to reallocate defect. 2. Replace drive. --------------------------------------------------------------------------- 66xx - 24 Media hard error. 1. Replace current DATA CD with different DATA CD. 2. Replace drive. --------------------------------------------------------------------------- 67xx - 24 Media hard error. 1. Ensure correct media type for this tape drive. 2. Replace current tape with new tape. 3. Replace tape drive. =========================================================================== Error Code Description Recommended Action =========================================================================== xxxx - 30 Controller timed out. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 31 Unrecoverable error. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 32 Controller/drive Replace the indicated device. disconnected. --------------------------------------------------------------------------- xxxx - 33 Illegal controller Replace the indicated device. command. --------------------------------------------------------------------------- xxxx - 34 Invalid SCSI bus phase. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 35 Invalid SCSI bus phase. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 36 Invalid SCSI bus phase. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 39 Error status from drive. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 40 Target timed out. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 41 SCSI bus stayed busy. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 42 ACK/REQ lines bad. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 43 ACK did not deassert. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 44 Parity error. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 50 Data pins bad. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 51 Data line 7 bad. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 52 MSG, C/D and/or I/O lines Replace the indicated device. bad. --------------------------------------------------------------------------- xxxx - 53 BSY never went busy. Replace the indicated device.
--------------------------------------------------------------------------- xxxx - 54 BSY stayed busy. Replace the indicated device. --------------------------------------------------------------------------- xxxx - 60 Controller CONFIG-1 Replace the indicated device. register bad. --------------------------------------------------------------------------- xxxx - 61 Controller CONFIG-2 Replace the indicated device. register bad. =========================================================================== Table 2-15. Pointing Device Interface Computer Checkup Error Codes =========================================================================== Error Code Description Recommended Action =========================================================================== 8601 - xx Pointing Device Interface 1. Run Computer Setup, test failed check trackball settings. 2. Clean trackball. 3. Reseat display cable in trackball board. 4. Reseat display cable in system board. 5. Verify that bottom of trackball board is not shorting to display shield. Place capton tape on bottom of board. 6. Replace trackball. 7. Replace display cable. 8. Replace system board. =========================================================================== 2.4 Troubleshooting Without Error Messages This section contains troubleshooting tables that provide a quick reference for diagnosing problems that cannot be identified by running POST or Computer Checkup (such as a non-functional display that does not allow viewing error messages). These tables address problems with: o Battery o Battery gauge o Diskette/diskette drive o Display o External device installation o Hard drive o Keyboard/numeric keypad o Memory o PCMCIA o Power o Printer o Software applications o Sound o Standby o System start o Trackball/mouse Since symptoms can appear to be similar, carefully match the symptoms of
the computer malfunction against the problem description in the troubleshooting tables to avoid a misdiagnosis. >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> WARNING >>>>>
battery gauge. ------------------------------------------------------- Battery pack was exposed Allow time for the battery to temperature extremes. pack to return to room temperature. ------------------------------------------------------- Battery pack is at end Install another battery of its life. pack. If this fixes the problem, original battery is no longer functional. ------------------------------------------------------- Battery contacts not Remove the keyboard cover making good contact with and examine the battery battery pack. contacts. Ensure that the battery pack is making good contact with all five sets of contacts. If not, gently bend the contacts on the system board so that the battery pack makes good contact. ------------------------------------------------------- Defective system board. Replace system board. =========================================================================== Problem Probable Cause Solution(s) =========================================================================== Computer shut Battery pack was not Next time, initiate Standby, down and data replaced within one wait until the power/standby was lost when minute when the light is flashing, and replacing the computer was in Standby. remove the battery pack. battery pack. Insert a charged battery pack within one minute. ------------------------------------------------------- Auxiliary battery charge Recharge the auxiliary is low, or the auxiliary battery. ** battery is at end of its life. ---------------------------- Replace the auxiliary battery. --------------------------------------------------------------------------- Every time the Auxiliary battery charge Recharge the auxiliary computer is is low or the auxiliary battery. ** turned on, date battery is at end of its and time must be life. set. ---------------------------- Replace the auxiliary battery. --------------------------------------------------------------------------- Battery charge Battery is being exposed Keep computer at a cooler does not last as to high temperature and recharge the long as expected. temperatures. *** battery. ------------------------------------------------------- Battery is being exposed Put computer in a warmer to low place and recharge the temperatures. *** battery. ------------------------------------------------------- Battery has partially Recharge the battery. self-discharged. ---------------------------------------------------------------------------
Battery charge Power conservation is Set a power conservation does not last as disabled or set to level. (Section 1.10). long as expected. None. ------------------------------------------------------- An external device or Turn off or remove the PCMCIA card is draining external device when not the battery. using it. --------------------------------------------------------------------------- Battery pack is Normal warming has No action is required. warm to the touch occurred due to after charging. charging. --------------------------------------------------------------------------- * For information on solving power problems, refer to Table 2-26. ** Refer to Auxiliary Battery in Section 1.6. *** The recommended storage temperature range for the battery pack is -4oF to 86oF (-20oC to 30oC ). The recommended operating temperature range is 50oF to 104oF (10oC to 40oC). =========================================================================== Table 2-17. Battery Gauge Problems =========================================================================== Problem Probable Cause Solution(s) =========================================================================== Battery gauge If battery pack is new, Fully charge the battery displays a question mark is pack until the battery LED question mark. displayed until battery turns off. If problem pack is fully charged. still exists, complete the following steps: 1. Allow the battery pack to cool off. 2. Partially discharge the battery pack. 3. Fully recharge the battery pack. ------------------------------------------------------- The battery pack has Fully charge the battery been unused for five or pack until the battery LED more days. turns off. ------------------------------------------------------- Battery pack has been Condition the battery pack * partially recharged too (Appendix B). many times without being fully recharged. --------------------------------------------------------------------------- Battery gauge Battery pack has been Condition the battery pack * appears partially recharged too (Appendix B). inaccurate. many times or computer has been in Standby for an extended period of time. --------------------------------------------------------------------------- * The battery pack needs to be conditioned every 60 days to maintain battery gauge accuracy. ===========================================================================
Table 2-18. Diskette/Diskette Drive Problems =========================================================================== Problem Probable Cause Solution(s) =========================================================================== Diskette drive Diskette is damaged. Run CHKDSK on the diskette. LED stays on. At the system prompt, type: CHKDSK A: ------------------------------------------------------- Software program is Check the program diskettes. damaged. --------------------------------------------------------------------------- Diskette drive Diskette is write- Disable the diskettes cannot write to a protected. write-protect feature or use diskette. a diskette that is not write-protected. ------------------------------------------------------- Computer is writing to Check the drive letter in the wrong drive. the path statement. ------------------------------------------------------- Drive error has Run Computer Checkup. occurred. ------------------------------------------------------- Diskette is not Format the diskette. formatted. --------------------------------------------------------------------------- Diskette drive The wrong type of Use the type of diskette cannot read a diskette is being used. required by the drive. diskette. ------------------------------------------------------- Diskette has a bad Copy files to the hard drive sector. or another diskette. Reformat or replace the bad diskette. ------------------------------------------------------- Drive error has Run Computer Checkup. occurred. ------------------------------------------------------- Diskette is not Format the diskette. formatted. =========================================================================== Table 2-19. Display Problems =========================================================================== Problem Probable Cause Solution(s) =========================================================================== Characters are Control slide for Adjust the slide control(s) dim. brightness or contrast on the right side of the (if applicable) is not display. * set properly. ------------------------------------------------------- Computer screen is in Tilt display or move direct light. computer. ------------------------------------------------------- Power Management setting Use the Fn + F7 hotkeys or is set on high or run Power Management to custom. change setting to medium. ------------------------------------------------------- Power Management Adjust brightness setting in brightness setting is Power Management.