Page 91

IMI66-112Voice Mail!
3.9.4 Voice Mail Port-Night Rin
For Automatic Attendant
8ingDeration
Description:You can program the voice mail port to ring differently in night mode.
Default = No night ring (All LJ3Ds = Ofi
To Program:1. Dial 54 “‘STA/LINE CONFIG”
2.Dial 3 “NIGHT RING”
3.Select line ports
Line port 
l- 6 = Dial 01 - 06 or press I31 - B6
4.Dial # when all line ports are selected
5.Select station ports to be programmed: station 11 - 25, Dial 11 - 25 or press A2 - Al6
6.Dial +C when all station ports...

Page 92

Voice MailZMZ66-1123.9.6 Automatic Transfer of Voice Mail
Description:When you include a voice mail system with the Unisyn telephone system, use this programming feature to
arrange for an immediate line transfer without delay from the voice mail system to a station port.
NOTE:Do not tarn on this feature if YOU tarn on the screen an&or confirm options provided by the voice mailsystem.
This is because the immediate transfer will preclude any screen or confirm action that the voice
mail can provide.
Default...

Page 93

ZMZ661123.9.8 Voice Mail Transfer on BusvVoice Mail
Description:
To Program:
Normally, the voice mail system automatically routes calls that are made to a busy station to that station’s
voice mail box. Alternately, 
you can arrange for the system to alert the busy station when the voice mail
system is attempting a call transfer to it.You may need to program the attendant station to have this option.
Default = Not enabled (Al-Al6 LEDs = OjjJ
1. Dial 53 “STATION FEATURES”.
2.Dial 31 “VMAIL XFR ON BSY”...

Page 94

Toll RestrictionIMZ66-112
3. IO Toll Res friction
Table Confiuuration
In order for toll restriction to take effect, you must perform all of the following functions:l
Program entries in one or more toll tablesl
Assign toll tables to all appropriate lines.l
Assign toll tables to all appropriate stations.>:..‘

Page 95

IMI66112Toll Restriction
3. IO Toll Restriction Configuration
NOTE: A lighted LED next to the programming button for the selection shows the choice you have selected.When
a single button provides 
a toggle (on/ofJ) action, the lighted LED indicates the active feature.
The first step in any programming sequence is to enter the base level. Once in this mode, you can dial the feature
code for any desired configuration. Enter the base level with the following procedure: press ITCM then dial
%# 7 4 6 SAC.The...

Page 96

Toll Restriction3.10.3 Assign Toll Restriction Tables To StationsIiW6&112Description:
Assign the toll restriction table to each appropriate station.
Default = None assigned.
To Program:1.Dial 73 “ASSIGN TOLL-STA. ”
2.Dial 01 - 16 for toll tables l-16 to be assigned to station
-OR-
Press Al - Al6 for tables 1-16 (LED On = Selected table)
3.Dial # to finish entry
4.Select station ports to be programmed: Station 10 - 25, Dial 10 - 25 or press Al - Al6
5.Dial +k for next toll table to station assignment,...

Page 97

IMI66-112Toll Restriction3.10.5 Assign Toll Restriction Tables
To System Speed Dial Calls
Description:When you enable this feature, the system applies toll restriction tables that you have assigned to a station to
the system speed dial calls that users make from that station.
Default = None assigned.
To Program:1. Dial 53 “STATION FEATURES”
2.Dial 05 “SYS SPD TOLL RST”
3.Select station ports to be programmed: Station 10 - 25, Dial 10 - 25 or press Al - A16
4.Dial +C for next station feature,
-OR-
Dial *...

Page 98

System ProgrammingIM166112
3. I I Programming Reference Chart
The following chart lists all of the Unisp programming options in their numerical order and provides you with an excellent
reference., You 
do not have to program the system in this order.
01
02
03
04
10
11
,
12
13
14
151
15,2
16
17,Ol
17,02
17,03
17,04
23
25
26
27
30
31
32
33
35
36
37
38
40
43
47
50,oo
51
52
53,Ol
53,04
53,05
53,06
53,07
53,09
53,ll
53,12
53,13
53,14
53,15System Clock
System Speed DialNight Mode
Music On Hold
System Default...

Page 99

IMI66-112System Programming3.12 Feature Code Numbering Plan
Feature
Dialing Code
All Call Page
Attendant Calling
Automatic Redialing
Background MusicITCM 87
ITCM 0 (or ITCM 9)
Programmed Button /Interactive Button
lTCM%llTCM#l
Automatic Callback
Call Forward
call Pickup
Call Waiting ToneActivate
Cancel
All Calls
Cancel
Directed
System
Send
CancelITCM, Extension, % 6ITCM#6
ITCM #+ 5, ExtensionII-CM # 5,
ITCM 
+K4, ExtensionII-CM # 4,
ITCM, Extension , 
t 01
Ha% UP
Do Not Disturb
Ha&free Answer Inhibit...

Page 100

ZMZ66-112System Records
.,;.-: ..;
,
Ll
4Programming Records 
-4.1 
Z$stem Programming-
iscellaneous FeaturesAttendant 
/ Line AccessO=Att 9=AttDefault = 0 For Attendant
Dialing Feedback
Mono DTMF /
I
IDefault = Monotone
Tone 
/ Voice SignalingToneVoice
Default = Voice
Exclusive HoldEnable Disable
,Dgfault = Disable
)
 Default = 1200 Baud 8 Data / 1 Stop BitsI
Make 
/ Break Ratio60140 67/33 /
Dgfault = 60 /40~
PA Options
Direct Ringing Lines (l-6)
rDelayed Ringing Lines (l-6)
Night Ringing Lines (l-6)...