Page 61

System Programming
3.5. IITiming Features-PA Port
Description:You can set PA ports to either timeout of the system for a programmed length of time or to remain on the
system as long as necessary without timing out. The system default is set for no timeout option.
-
Default = No Timeout (Al3 LED = On)
To Program:1. Dial 92 “PA TIMEOUTBY
2.Choose Timeout length:
Press 
Al or dial 1 = 30 sec.“PA TIMEOUT 30”
Press A2 or dial 2 = 60 sec.“PA TIMEOUT 60”
Press A3 or dial 3 = 90 sec.“PA TIMEOUT 90”
Press A4 or...

Page 62

System ProgrammingIMI66-112
3.5.13 Timing Features-RecalUFlash
Description:The system can generate either a line disconnect (recall) or a host system feature access signal (flash)
depending upon the programmed time.
Default = 2 sec. (Al2 LED = On)
To Program:1. Dial12RECALL/FLSHZXX
2. Select time:
Dial 1 or Press 
Al = 0.08 sec.RECALVFLSHO.08
Dial 2 or Press A2 = 0.30 sec.RECALLlFLSH 0.30
Dial 3 or Press A3 = 0.50 sec.RECALLfFLSHO.507
Dial 4 or Press A4 = 0.60 sec.RECAL.UFLSHO.60;
Dial 5 or Press A5 =...

Page 63

In!fI66-112
System Programming3.5.15 
Timin Features-Unanswered
Call ransfer Recall Time3
Description:A transferred call that remains unanswered after a programmed length of time will return to the transferring
station for answering.Set the transfer recall time with this programming procedure.
Default = 20 sec. (A2 LED = On)
.-.
ToProgram:1.Dial 11 “STA XFR RCL XXX ”
2.Choose transfer time:
Dial 1 or Press Al = 10 sec.
Dial 2 or Press A2 = 20 sec.
,
Dial 3 or Press A3 = 25 sec.
Dial 4 or Press A4 = 30...

Page 64

Line ProgrammingIMI64-I123.6 Programming The Lines
3.6. IIn troducfion
You can program the parameters for individual lines by using line class of service programming.
The programming
decisions you make, therefore, will only be true for that line and not for the entire telephone system, as is the case for
system configuration. You should keep a record of all programming decisions that you make-it will help you keep
track of what you have done and will help you troubleshoot any problem that might arise...

Page 65

IMI66-112Line Programming3.6.2 Abandoned Hold Release
Description:
To Program:When a distant party abandons a hold condition and disconnects from a line (hangs up), the central office
sends a positive disconnect signal to the Unisyn telephone system. This signal can be either 
50 m,sec. or
350 msec. Check the signal length from the telephone company and program all of the central office line
ports to match that signal length.
Default = 50 msec. (BI - B6 LEDs = On)
1.Dial 38 “HOLD RELEASE 50 ”
2.Select...

Page 66

Line ProgrammingIMI66-I123.6.5 Line Groups
Description:Group outside lines of the same type together for dial-up outgoing access. Access codes for the line groups
are as follows:
Group
1=Dial9 orDial0(SeeSection3.5.1)
Group2=Dial
81
Group3=Dial82
Group4
=Dial83
NOTE:Assigning lines to groups automatically arranges the system for hybrid operation.Remember, hybrid5,L,
operation may incur a higher monthly tarifs than the key system operation incurs.Ask the local telephone;.I
company for details.._
Default =...

Page 67

In!iI66-112
Line Programming3.6.6 Line Fort Functions-Line Disable
Description:You can take a line port out of service when necessary (because of defect, for example) using this
programming procedure.Return the line to service with the central 
office lines programming procedure
(Section 3.6.8).
Default = None disabled (Bl - B6 LEDs OfjJ
::
To Program:1. Dial 31 “DISABLE LINES”
2.Select line ports to be disabled (LED On = Disabled)
Line port 1-6 = Dial 
01 - 06 or Press Bl - B6
3.Dial +k for...

Page 68

Line ProgrammingIM1661123.6.9 Pulse/Tone Switchable-Pulse
Description:If the installer has connected rotary dial lines to the system, you must condition those line ports as pulse
dial ports.NOTE:
The user can switch from pulse (rotary dial signaling) to tone (dual tone multiple frequency - DTMF) 
accessing special circuits requiring DTMF tones, such as banking machines, when they need to do so 
from
a rotary dial line by dialing #after dialing access number.
Default = No pulse (Bl - B6 LEDs Off)
To...

Page 69

ZMZ66-112
Station Programming3.7 Programming The Stations
3.7.1 Introduction
Station programming means that you are programming the functions for one particular station, or port. While it isn’t
necessary, it is a good idea to do station programming after you have done system and line programming. You
should keep a record of programming decisions that you make-it will help you keep track of what you have done
and will help you troubleshoot any problem that might arise later. When you need to make a record...

Page 70

Station ProgranzmingIMI66-I123.7.3 
All-Call and Zone Paging
Description:Telephone users can receive voice announcements through their telephone loudspeakers or through an
external paging amplifier and speaker connected to a PA port.They can transmit these voice
announcements with their telephone handsets. You can arrange the programming so that the users can
make announcements to stations located in certain areas of the site or to all of the stations.You can also
arrange stations to originate but not...