2.5.4 Speed Dial Records 400—499
Dialing
Code*Line
Selection**Prefix*** Number****Dialing
Code*Line
Selection**Prefix*** Number****
*Enter 400–499 for dialing codes 400–499
**Enter line number, line group number, prime line/last line used—Beginning with software release 8.B,
you can assign intercom as a preselect choice.
***Enter 1–128 for line or enter 1–16 for line group
****Enter 32 digits maximum—enter P for pause and F for hookflash
IMI66–125DXP Plus Programming Records
2–8  System Records 

Page 1022

2.5.5 Speed Dial Records 500–599
Dialing
Code*Line
Selection**Prefix*** Number****Dialing
Code*Line
Selection**Prefix*** Number****
*Enter 500–599 for dialing codes 500–599
**Enter line number, line group number, prime line/last line used—Beginning with software release 8.B,
you can assign intercom as a preselect choice.
***Enter 1–128 for line or enter 1–16 for line group
****Enter 32 digits maximum—enter P for pause and F for hookflash
DXP Plus Programming RecordsIMI66–125
System Records 2–9 

Page 1023

2.6 Timing
Call Park Recall 0 sec 1 min2 min3 min 4 min 5 min 6 min
Page Recall 0 sec 1 min2 min3 min 4 min 5 min 6 min 7 min 8 min 9 min 10 min
Camp-on Tone 5 sec 10 sec15 sec30 sec 1 min 2 min 3 min 4 min 8 min
DTMF Extended Dialing80 ms160 ms 240 ms 320 ms 400 ms 560 min 720 ms 880 ms 1.04 sec
Hold Recall 0 sec 30 sec 1 min 1.5 min 2 min 3 min 4 min 5 min 6 min
Attendant Hold Recall 0 sec 30 sec 1 min 1.5 min2 min3 min 4 min 5 min 6 min
Paging Access20 sec30 sec 1 min 1.5 min2 min2.5 min 3 min
Pause...

Page 1024

2.7 System Parameters
Synchronized RingingNoYes
Automatic Attendant Immediate TransferNoYes
ARS (Automatic Route Selection)DisabledEnabled
ARS Dial Tone1234
System Status ReportingDisabledEnabled
T1 Status ReportingDisabledEnabled
Central Message DeskNoneName Number
IST Ringing Per Phase816
IST Ringing ModesMode 1 (2 sec.)Mode 2 (1 sec.)
IST Ring Frequency21 Hz25 Hz
Operator Station101Name Number
Line Problem Limit (0 = disabled)
(1–255 = choices)
0
Master CFOS Control DisabledEnabled
Line Disconnect...

Page 1025

2.8 Zone Paging
Zone 1(Defaults to All-Call)*Record
Zone Name
Transmit Station (101-292)
Relay Assigned (1-4)
External Paging Port rt Assigned 0=No 1=yes
Zone 2Record
Zone Name
Transmit Stations (101-292)
Receive Stations (101-292)
Relay Assigned (1-4)
External Paging Port Assigned 0=No 1=yes
Zone 3Record
Zone Name
Transmit Stations (101-292)
Receive Stations (101-292)
Relay Assigned (1-4)
External Paging Port Assigned 0=No 1=yes
Zone 4Record
Zone Name
Transmit Stations (101-292)
Receive Stations...

Page 1026

2.12 Feature Renumbering
Feature Name Default Code New Code Feature Name Default Code New Code
Park Orbits User Features
Park Orbit Send 1S91 Background Music 1T11
Park Orbit Send 2S92 Background Music 2T12
Park Orbit Send 3S93 Background Music Off #1
Park Orbit Send 4S94 Volume SaveTT7
Park Orbit Send 5S95 Operator 0
Park Orbit Send 6S96 Account Code EntryT04
Park Orbit Send 7S97 Call Forward Cancel #5
Park Orbit Send 8S98 Call Forward PersonalT51
Park Orbit Send 9S99 Call Forward All CallsT52
Park...

Page 1027

2.13 Enabling T1 Status Reporting And Major Alarm Alerting
FeatureSettings* Default
T1 Status ReportingEnabled Disabled Disabled
Major Alarm AlertingEnabled Disabled Disabled
*Mark block to match desired setting
NOTE: The T1 status reporting and major alarm alerting parameters are described in the instructions, “Installing And Programming
The DXPT1 Digital Carrier Transmission Option,” IMI89-193. These instructions should be located in this book under the
installation tab.
2.14 T1 Status Logging
Error...

Page 1028

2.15 Major Alarm Alerting
Error TypeThreshold Time Period
Range Selection Range Selection
1. Bipolar Error 0-999 See Note A
2. CRC Error 0-999 See Note A
3. Slip Errors 0-999 See Note B
4. PLL Errors 0-999 See Note A
5. Transmit Slip Errors 0-999 See Note B
6. Loss of Sync 0-999 See Note B
7. Blue Alarms 0-999 See Note B
8. Loss of Signal 0-999 See Note B
9. Primary/Sec Sync Ref Switch 0-999 See Note B
10. Sync Phase Lock Error 0-999 See Note B
11. Yellow Alarms 0-999 See Note B
12. Red Alarms 0-999 See...

Page 1029

Station Records
·From main menu, type selection number for station menu and pressENTER.
·From station menu, type selection number for feature and pressENTER.
Stations
1. COS Programming
2. Station Programming
3. Button Mapping
4. Phone Types
5. Copy Model COS
6. Copy Model Station
7. Copy Model Button Map
8. Hunt Groups
Enter Selection (1-7):
3
DXP Plus Programming Records IMI66–125
Station Records 3–1 

Page 1030

3.1 COS Programming
(Copy This Sheet As Needed To Meet System COS Capacity)
32 1 2–31Account Code YES NOYes No No
Auto Hold on Intercom YES NONo No No
Auto Hold on Lines YES NONo Yes No
Background Music YES NOYes No No
Call Cost Display YES NONo No No
Call Forward All YES NOYes Yes No
Call Forward Busy/RNA YES NOYes Yes No
Call Forward Personal YES NOYes Yes No
Call Forward Off Site (CFOS) YES NONo No No
Call Park Access NONE, 1–91–9 1–9 None
Call Pick-up YES NOYes Yes No
Call Waiting YES NOYes Yes No...