DXP Plus Programming instructionslMl66-123
10.2. IManual ReDortsDescription:Use the following programming procedure to manually command a printout to occur.
Programming:1. Press CONTROL T for main menu.
2. From main menu, select printouts and press ENTER.
3. From printouts menu, select 
SMDAISMDR and press ENTER,
4. From 
SMDABMDR menu, select SMDA reports and press ENTER.
5. From SMDA reports menu, select desired report and press ENTER.
6. Press ESCAPE to end.
10.2.2Aufomafic ReDor&Description:Program...

Page 192

10.2.3SMDA Retort ExamDIes
LINE GROUP SUMMARY__D---___--_D_------_o___o________LINE GROUPACCESSESFAILURES
--m-m-------
o--
3-
p
w-------
173112
480
500
908
1000
1100
1200
1300
1400
1500
1600
__D---D_--___D--_o-_DDDD-Do----poD
10-IQ Call Costing and SMDABMDR Programming 

Page 193

DXP Plus Programming InstructionslMl66-123
10.3Account Codes (Forced, with Positive Verification)
10.3.1Account Code (System Parameters)Description:
Account codes are used to identify calls by category or by any other desired grouping, so that
the system can record costing by that category. You can arrange the system to force the user to
enter an account code and have the system verify it before it allows the user to make a call. Turn
on the account code feature for the entire system using this...

Page 194

/M/66-123DXP Plus Programming Instructions
10.3‘3Account Code LengfhDescription:
An account code can be a minimum of three digits or a maximum of 16 digits.
Use this
procedure to set the amount of account code digits.
NOTE: If you change the account code length you will delete
all currently programmed account codes.
Programming:1. Press CONTROL T for main menu.
2. From main menu, select SMDAISMDR and press.
3. From 
SMDAKMDR menu, select SMDABMDR parameters and press ENTER.
4. From SMDABMDR parameters...

Page 195

DXP Plus Programming Instructions/M/66-123
10.3.5Account Code (For Class Of Service)Description:
After you have enabled the account code feature for the system, set its parameters, and
programmed its list of account codes into the system, turn the feature on for a station class of
service and make it either forced or optional.If you make it a forced account code, the user
must enter an account code before the system will let him or her dial the number for an outgoing
call. Also, on incoming calls a user...

Page 196

10.5Authorization Code
Description:
Authorization codes provide system users the mobility to use their class of service (COS)
features, prime line assignments, and exception numbers on any telephone in the system instead
of being limited by what is available to the particular telephone they happen to be using.
One
popular term for such a feature is walking class ofservice. Authorization codes are associated
with personal intercom numbers as are COS, prime markings, and exception numbers.
Therefore, when...

Page 197

Programming Toll Resfricfionl Toll Restriction Example 1...............
11.1l 
TollRrestriction Example 2...............11.2l Toll Restriction Flow Diagram
.............
11.3l Restriction Level Programming.............
11.4l Toll Groups 
Programming................11.5l Restricted Numbers Programming...........
11.6l Exception Number Programming............
11.7
With the toll restriction feature, the system allows or denies outgoing line calls to selected users over selected
lines. Toll restriction meets...

Page 198

/M/66-323DXP Plus Programming instructions
11.1Toll Restriction Example “I
In this example, the chief executive can dial all telephone numbers exce\
pt those numbers with a restriction level
of always deny. The section manager can dial all numbers except those in\
 restriction level 8 (international
numbers over lines assigned 
totoll group 1) and those numbers with a restriction level of always deny. Th\
e unit
manager can dial all numbers except those numbers in restriction levels \
7 and 8...

Page 199

DXP Plus Programming InstructionsIMl66-123
11.2Poll Restriction Example 2In this example, assume that you have assigned the following restriction levels and exception numbers to 
thefollowing people in a company: Keep in mind that you assign restriction level to stations by programming the
class of service with a particular restriction level while you assign exception numbers to individual stations
through station programming.
StationRestriction LevelException Number
President
8NONE
Executive
7NONE...

Page 200

/M/66-123BXP Plus Programming Instructions
11.3Toll Restriction Flow DiagramFLOWCHRT
Station Begins
DialingLine calls are
subjected to toll
restriction examination
Complete
Dialing
AllowedYES
CompleteYES _Dialing
Allowed
Compare Restriction
Level of Matched
Number with
Restriction Levels of
Station Class of Service
Eight (8) levels plus always
allow and always deny
m One level assigned foreach C.O.S. type or assign
allow all or deny all
Compare Exception
Number of Matched
Number with Exception
Number of...