Page 191
DXP Plus Programming instructionslMl66-123 10.2. IManual ReDortsDescription:Use the following programming procedure to manually command a printout to occur. Programming:1. Press CONTROL T for main menu. 2. From main menu, select printouts and press ENTER. 3. From printouts menu, select SMDAISMDR and press ENTER, 4. From SMDABMDR menu, select SMDA reports and press ENTER. 5. From SMDA reports menu, select desired report and press ENTER. 6. Press ESCAPE to end. 10.2.2Aufomafic ReDor&Description:Program...
Page 192
10.2.3SMDA Retort ExamDIes LINE GROUP SUMMARY__D---___--_D_------_o___o________LINE GROUPACCESSESFAILURES --m-m------- o-- 3- p w------- 173112 480 500 908 1000 1100 1200 1300 1400 1500 1600 __D---D_--___D--_o-_DDDD-Do----poD 10-IQ Call Costing and SMDABMDR Programming
Page 193
DXP Plus Programming InstructionslMl66-123 10.3Account Codes (Forced, with Positive Verification) 10.3.1Account Code (System Parameters)Description: Account codes are used to identify calls by category or by any other desired grouping, so that the system can record costing by that category. You can arrange the system to force the user to enter an account code and have the system verify it before it allows the user to make a call. Turn on the account code feature for the entire system using this...
Page 194
/M/66-123DXP Plus Programming Instructions 10.3‘3Account Code LengfhDescription: An account code can be a minimum of three digits or a maximum of 16 digits. Use this procedure to set the amount of account code digits. NOTE: If you change the account code length you will delete all currently programmed account codes. Programming:1. Press CONTROL T for main menu. 2. From main menu, select SMDAISMDR and press. 3. From SMDAKMDR menu, select SMDABMDR parameters and press ENTER. 4. From SMDABMDR parameters...
Page 195
DXP Plus Programming Instructions/M/66-123 10.3.5Account Code (For Class Of Service)Description: After you have enabled the account code feature for the system, set its parameters, and programmed its list of account codes into the system, turn the feature on for a station class of service and make it either forced or optional.If you make it a forced account code, the user must enter an account code before the system will let him or her dial the number for an outgoing call. Also, on incoming calls a user...
Page 196
10.5Authorization Code Description: Authorization codes provide system users the mobility to use their class of service (COS) features, prime line assignments, and exception numbers on any telephone in the system instead of being limited by what is available to the particular telephone they happen to be using. One popular term for such a feature is walking class ofservice. Authorization codes are associated with personal intercom numbers as are COS, prime markings, and exception numbers. Therefore, when...
Page 197
Programming Toll Resfricfionl Toll Restriction Example 1............... 11.1l TollRrestriction Example 2...............11.2l Toll Restriction Flow Diagram ............. 11.3l Restriction Level Programming............. 11.4l Toll Groups Programming................11.5l Restricted Numbers Programming........... 11.6l Exception Number Programming............ 11.7 With the toll restriction feature, the system allows or denies outgoing line calls to selected users over selected lines. Toll restriction meets...
Page 198
/M/66-323DXP Plus Programming instructions 11.1Toll Restriction Example “I In this example, the chief executive can dial all telephone numbers exce\ pt those numbers with a restriction level of always deny. The section manager can dial all numbers except those in\ restriction level 8 (international numbers over lines assigned totoll group 1) and those numbers with a restriction level of always deny. Th\ e unit manager can dial all numbers except those numbers in restriction levels \ 7 and 8...
Page 199
DXP Plus Programming InstructionsIMl66-123 11.2Poll Restriction Example 2In this example, assume that you have assigned the following restriction levels and exception numbers to thefollowing people in a company: Keep in mind that you assign restriction level to stations by programming the class of service with a particular restriction level while you assign exception numbers to individual stations through station programming. StationRestriction LevelException Number President 8NONE Executive 7NONE...
Page 200
/M/66-123BXP Plus Programming Instructions 11.3Toll Restriction Flow DiagramFLOWCHRT Station Begins DialingLine calls are subjected to toll restriction examination Complete Dialing AllowedYES CompleteYES _Dialing Allowed Compare Restriction Level of Matched Number with Restriction Levels of Station Class of Service Eight (8) levels plus always allow and always deny m One level assigned foreach C.O.S. type or assign allow all or deny all Compare Exception Number of Matched Number with Exception Number of...