3.14.6 Positive Disconnect Supervision
Description:When a voice mail station is on line with an outside caller and the caller hangs up, the
CO may send a positive disconnect signal to the DSU II. You can enable the positive
disconnect supervision feature on a per-line basis. If you enable positive disconnect
supervision, when the system receives the CO’s positive disconnect signal the system
tells the voice mail equipment to hang up.
To Program:1. Dial48.“DIS. SUPERVISION”
2. Select line ports for...

Page 232

3.15 Versatile Voice Processing
The digital telephone system supports the Versatile Voice Processing (V.V.P.) voice mail system. In
addition to the programming requirements detailed in Section 3.14, the following sections detail specific
procedures for programming the system to support the V.V.P. voice processing system.
3.15.1 Using The Tracker Paging System With Versatile Voice Processing
Description:The Tracker is available for use with the DSU II digital telephone system. To make
effective use of a...

Page 233

3.15.2 Using Tracker For Message Notification
Description:You can program the Tracker to notify mail box users when they have new messages.
To Program:In theMessage Deliveryfield for all mail box owners with  a Tracker, enter the following
code:,T01,X
3.15.3 Transferring Callers To Voice Mail
Description:You can program aTransfer To Voice Mailbutton to automate the process of transferring
a caller to a mail box. Use this button in conjuction with a DSS or a mail box extension
number followed by a2.
To...

Page 234

3.15.5 Visual Voice Mail Support
Description:Visual Voice mail (VVM) support provides proprietarty, two-line display LCD
speakerphone stations with visual messages and interactive buttons. This message and
button functionality enhances the station’s use with V.V.P. voice mail equipment.
NOTE: If the V.V.P. system includes the Visual Voice Mail option, you can not use Tracker and
VVM at the same time since they both use the COM 1 serial data port.
To Program:1. Dial17.“SYSTEM FEATURES”
2. Dial12.“VMM...

Page 235

3.16 Integrated Call Costing
Call costing provides a means of establishing costing that the system can apply to outside calls made from
system telephones. Call costing computes charges for a call after it is completed. It does not restrict
dialing as toll restriction does. The system provides several ways of establishing call costing that are as
follows:
·exception tables for local and long distance calls,
·office code band tables for local calls,
·zone call band tables for long distance calls,
·area...

Page 236

3.16.1 Call Costing Flow Diagram Examples
Call Costing Flow Diagram
DSU II Digital Telephone System IMI66–132
Programming The DSU II System 3 – 115 

Page 237

Example A For Local Dialing Sequence(201-nnnn)
For this example, assume that you have installed the digital telephone system in a location where callers
have an opportunity to dial number combinations that contain a common sequence in both the area and
office code.
The illustrated sequence is a local call (less than 10 digits) and 201 is the office code. Program call rate 18
to cost calls of this sequence. Also program the office code band table by assigning office code 201 into
band one. Note that the...

Page 238

Example B For Long Distance With Office Code Dialing Sequence(1-201-201-nnnn)
The illustrated sequence is a long distance call (more than 10 digits) with 201 as both the area code and
the office code. Program call rate table 25 to cost calls of this sequence. Also, program the zone call band
table by adding office code 201 to area code 201 in band one. Add any other office codes (for example
478) to area code 201 in band one as required.
DSU II Digital Telephone System IMI66–132
Programming The DSU II...

Page 239

Example C For Long Distance Dialing Sequence(1-201-nnn-nnnn)
This illustrated sequence is a long distance call (more than 10 digits) with 201 as the area code. Program
call rate table 11 to cost calls in this sequence. Also, program the area code band table by adding area
code 201 to band one.
IMI66–132 DSU II Digital Telephone System
3 – 118 Programming The DSU II System 

Page 240

Example D For Exception Dialing Sequence(nnn-nnnn, 1-nnn-nnnn)
Program call rate table one to cost calls that do not match any other programmed call rate table.
DSU II Digital Telephone System IMI66–132
Programming The DSU II System 3 – 119 