Page 51
IMI 66-083Installa+’ COMMON AUDIBLE AND AUXILIARY RINGING INTERFACE Relay closure dry-contact points are available for controlling external audible equipment. These contact closures track the pattern of the ringing . The contacts are closed during the ringing period and are open during the silent period. A typical common audible connection is illustrated on Figure3-9 below. Do not exceed a 1 amp at 24 volts (0.5 amp at 48 volts) load on these control terminals. If the load requirements exceed this...
Page 52
AonIMI 66-083 EXTERNAL PAGING INTERFACE A special transformer-isolated paging port is used to couple the system to an external paging amplifier. Relay closure dry-contact points are available at the ringing port terminal and can be used for controlling the external paging amplifier during a paging operation. These contacts close and stay closed during the time that a paging operation is active to provide a constant enable signal path for the paging amplifier. NOTE: This paging enable constant closure...
Page 53
IMI 66-083Installa:. EXTERNAL PAGING INTERFACE - LINE PORT A line port can be configured by class of service programming to be an AUXILIARY port. As an AUXILIARY port, it can be used to couple a station to an external paging device. This coupling is done from any station with that line presence by pressing the proper line key to select the AUXILIARY port. DTMF tones or dial pulses can be dialed through the AUXILIARY port as needed. The paging enable relayclosure feature is not available for use with...
Page 54
-ionIMI 66-083 . . .: DATA DEVICE CONNECTIONS ‘The sys?em provides two RS232 Data Ports for use. l When a video display terminal (VDT) is used to perform class of service programming, connect it to RS232 Data Port A. l When a serial data printer is used for SMDR, SMDA, and CCS printout, connect it to the RS232 Data Port B. The distance between the data device and the common equipment can be up to 500 feet in a quiet electrical environment. Shielded cable may be required at some sites for long runs. For...
Page 56
itrionIMI 66-083 MUSIC INTERFACE If music is to be part of the system, connect a customer-provided music source to the common equipme,nt music interface jack (phono jack) provided for this puwse as shown below in Figure 3-13. Theimpedance of this input is approximately 500 ohms. Use the volume control on the music source to adjust the audio level of the music as required.MUSIC SOURCE (FOR MUSIC ON tii&DFND BACKGROUND Figure 3-13. Music Interface 3-22
Page 57
IMI 66-083Instalk:SECTION 3 ADD-ON EXPANSION MODULES INTRODUCTION One or two optional add-on expansion modules can be installed on the common equipment base unit to increase the line and station capacity of an installed system. The add-on module is as follows: l 408 Expansion Module - A four-line by eight-station expansion unit The expansion capabilities provided by the add-on module are shown in Figure 3-14 on the next page. The default numbering of the expanded lines and stations begin with the next...
Page 58
InstallationIMI 66-083 4-LINE, &STATION BASE UNIT24-PORT SYSTEM&LINES AND 16.STATIONS (BASE “NlT PLUS ONE EXPANSION MODULE) 36-PORT SYSTEM12.LINES AND PI-STATIONS (BASE UNIT PLUS ONE EXPANSION MODULE)&LINE, l&STATION BASE UNIT 4&PORT SYSTEMl&LINES AND 3%STATIONS (BASE UNlT PLUS TWO EXPENSION MODULES) 2C-LINES AND40-STATIONS (BASE IJNlT PLUS ONE EXPANSION MODULE) 72.PORT SYSEM24.LINES AND 4BSTATIONS (BASE UNlf PLUS TWO EXPANSION MODULES) Figure 3-14. Add-On Expansion Module COnfigWatiOn3-24
Page 59
IMI 66-083Installa-‘onTable 3-6. Statlon Connections - 408 Expansion Module MOWN-WHITE WHITE-SLATE ISLATE-WHITE 4 309 510PATH SLATE-VIOLET sTA.l STA 1M 2M 3M 4M 5M 6M 7M 6M POWER STATION NNECTIONS .OCATlON3-25
Page 60
mstallat/$nIMI 66-083INSTALLATION Each add-on expansion module measures 15.5 wide x -1.4 high x 1.6 wide and weighs approximately 4 pounds. The modules are designed to be attached to the base unit and connected to it via cabling. l The first module must be connected to the upper location on the base unit. To install an expansion module to a base unit, refer to Figure 3-15 and perform the following procedure. 1. Disconnect both AC power and external battery back-up power from the system. 2. Remove and set...