7. Connections AC Power Specifications AC Power VoltageAuto Range 100 – 240V AC Power Current3A–1.5A/50–60Hz Main FuseMain Power Supply: T4A H 250V Power Consumption Normal operation mode270 W Standby mode8W 7.1.4 Power Connection Cine VERSUM 120 AC Power Cord connection Use the supplied power cord to connect the Cine VERSUM 120 to the wall outlet. First, remove the back cover (1) (turn the quarter turn fastener a quarter turn counterclockwise to unlock cover) and the power input cover (2) to allow the power plug insertion. Then, plug the female power connector into the male connector at the rear of the unit. Make sure that the power plug is firmly inserted into the AC socket and the power cable routed from the bottom side. A 12Image 7-8 Projector covers removal A Quarter turn fastener 1 Rear cover 2 Power input cover A B Image 7-9 Power connection A Right angle power socket B Power cable routing AC Power Specifications AC Power VoltageAuto Range 90 – 240V AC Power Current7.0A–2.9A/50–60Hz Main FuseMain Power Supply: T15A H 250V Power Consumption Normal operation mode650 W (Dual lamp) -355 W (Single lamp) Standby mode14 W 7.1.5 Power Connection Cine VERSUM 50 AC Power Cord connection Use the supplied power cord to connect the Cine VERSUM 50 to the wall outlet. Plug the female power connector into the male connector at the rear of the unit. Make sure that the power cord is firmly inserted into the AC socket. R5976468 CINE VERSUM SYSTEM 03112003 47
7. Connections Image 7-10 AC Power Specifications AC Power VoltageAuto Range 100 – 240V AC Power Current4.0 –1.5 A / 50 – 60 Hz Main FuseStandby Power Supply: T 2AH/250V Main Power Supply: F 10AH/250V Power Consumption Normal operation mode350 W Standby mode4W 7.2 Connection for Preview and Communication Overview • Connection for Preview Monitors • Connection for Communication • Network Connection 7.2.1 Connection for Preview Monitors Connection possibilities The5BNC’son the output module carry the RGB Analog Video output signal with Separate Sync (H & V) for preview monitors or for any non-Cine VERSUM System display matching the output timings. The supplied RGB Analog video signal has the same resolution as the digital video output. 48 R5976468 CINE VERSUM SYSTEM 03112003
7. Connections Image 7-11 Monitor connection Analog Output Timings Vertical SyncPalNTSCPC/no signal Period20 msec16.7 msec16.7 msec Sync Width514 µsec428 µsec428 µsec Back Porch27.8 µsec23 µsec23 µsec Front Porch2.58 msec1.26 msec1.26 msec Active Signal16.9 msec15 msec15 msec Horizontal SyncPalNTSCPC/no signal Period23.4 µsec19.6 µsec19.6 µsec Sync Width2.30 µsec2.00 µsec2.00 µsec Back Porch1.8 µsec1.5 µsec1.5 µsec Front Porch1.12 µsec680 nsec940 nsec Active Signal18.2 µsec15.4 µsec15.2 µsec • Back Porch = from rising edge of Sync to begin of active video. • Front Porch = from end of active video to falling edge of Sync. 7.2.2 Connection for Communication Purpose The two D9 connectors RS422/RS232 In- and Output are defined as open standard for Communication with other Devices such as Control Panels (AMX, CrestonTM) and Audio Switchers). R5976468 CINE VERSUM SYSTEM 03112003 49
7. Connections Image 7-12 Communication connection RS232/422 INRS232/422 OUT PinRef.PinRef.Description 1DCD_INData Carry Detect 6RXD+/DSR_IN6RXD+/DSR_OUTRead Data/Data Set Ready 2RXD-_IN2RXD-_OUTRead Data 3TXD-_IN3TXD-_OUTTransmit Data 8CTS_INClear To Send 4TXD+/DTR_IN4TXD+/DTR_OUTTransmit Data/Data Terminal Ready 9RI_INRing Indicator 5/10GROUND5/10GROUNDGROUND 7.2.3 Network Connection Purpose Controlling and monitoring of the Cine VERSUM Master settings. Remote diagnostics to detect potential errors. Actually, this connection is not supported internally (Development status). 50R5976468 CINE VERSUM SYSTEM 03112003
7. Connections Image 7-13 Network connection 7.3 Digital Link to Display Modules Overview • Cine VERSUM System Link • Digital Link to One Display • Digital Link to More Displays (Loop-through) • Digital Link Cable for long distances 7.3.1 Cine VERSUM System Link General info BARCO’s unique and proprietary digital link concept allows you to distribute both uncompressed high definition video images and two-way communication between the different Cine VERSUM System display modules throughout the network. The no-compromise design of the Cine VERSUM System link allows for a throughput of 1,063 GB per second and per color to be achieved, resulting in a data streaming digital video distribution over the link of 3,18 GB per second. Designed to provide the user with ulti-mate flexibility, the link allows for distances of up to 40 meters between each module. As such it is possible to connect up to a maximum of 32 different Cine VERSUM System display modules to one single Cine VERSUM Master over a total cable length of 1280 meters! BARCO’s Cine VERSUM System digital link comes in two different versions: a flexible cable for shorter distances (SL link) and a more shielded, rigid cable for longer distances (XL link). The length of the rigid cable can be custom made according to the requirements of each individual installation, up to a maximum length of 40 meters. Available digital link cables Order NumberDescription R9841350Cable CINEVERSUM SL 1,5m R9841360Cable CINEVERSUM SL 5m R9841370Cable CINEVERSUM SL 15m R9841380Cable CINEVERSUM XL xx m (Megaline cable on request) R9841400Cable CINEVERSUM XL Connnector (Female for long distance cable)+wall outlet+clips. R5976468 CINE VERSUM SYSTEM 0311200351
7. Connections 7.3.2 Digital Link to One Display How to link The digital output module on the Cine VERSUM Master is provided with one single output cable connector for SL type cable (for both video and communication). Insert the plugs of the patch cord respectively into High Speed Link OUT on the digital module of the Cine VERSUM Master and Link IN on the Cine VERSUM 50 (image 7-14),Cine VERSUM 80 (image 7-15), or Cine VERSUM 120 (image 7-16) To preserve image performances, limit the length of the patch cable, when using cable of type SL, to 15 m. For longer distances between both units, cable of type XL is recommended. Image 7-14 Digital link with Cine VERSUM 50 Image 7-15 Digital link with Cine VERSUM 80 52R5976468 CINE VERSUM SYSTEM 03112003
7. Connections Image 7-16 Digital link with Cine VERSUM 120 7.3.3 Digital Link to More Displays (Loop-through) How to link (e.g. a Cine VERSUM 50, a Cine VERSUM 80 and a Cine VERSUM 120) The digital output module on the Cine VERSUM Master is provided with one single output cable connector for SL type cable (for both video and communication) with loop-through possibility on the Display Modules. • Insert the plugs of the patch cord respectively into High Speed Link OUT on the digital module of the Cine VERSUM Master and Link IN on the Cine VERSUM 50. • Insert the plugs of the patch cord respectively into the Link OUT on the Cine VERSUM 50 and the Link IN on the Cine VERSUM 80. • Insert the plugs of the patch cord respectively into the Link OUT on the Cine VERSUM 80 and the Link IN on the Cine VERSUM 120 (last display in the chain). R5976468 CINE VERSUM SYSTEM 03112003 53
7. Connections Image 7-17 Digital link with Cine VERSUM 50, Cine VERSUM 80 and Cine VERSUM 120 7.3.4 Digital Link Cable for long distances Whichcablehastobeused The XL cable allows the link for distances of up to 40m between each module. As such it is possible to connect up to a maximum of 32 different Cine VERSUM System display modules to one single Cine VERSUM Master over a total cable length of 1280m. Image 7-18 Digital link cable long distance 54R5976468 CINE VERSUM SYSTEM 03112003
7. Connections Image 7-19 Digital linking long distance via wall outlet 7.4 Connection to Video Equipment Overview • Input Connection per Module • Installation of an Input module General The Cine VERSUM Master acts as the control unit of the complete Cine VERSUM System. It can be equipped with up to 8 digital and analog input modules which enable it to process all types of video, component video, RGB, SDI, HD-SDI, DVI and any future video standardizing. Image 7-20 Input modules overview 1 RGB / YPrPb Input module 2 Video Input module 3 Video Input module 4 SDI Input module 5 HD SDI Input module 6-8 Free input slots (can be filled up with one of the above modules) R5976468 CINE VERSUM SYSTEM 03112003 55
7. Connections 7.4.1 Input Connection per Module Video Input module Image 7-21 Video Input module Input modeSignal format (1), (2) or (3) selectable DecoderDigital Multistandard Decoder, running at twice the oversampling rate (27 MHz). - PAL, PAL M, PAL N - NTSC, NTSC M, NTSC Japan, NTSC 4.43 - SECAM Comb FilterAdaptive 2/4 line Comb Filter for two dimensional Y/C separation Features- Built in Copy-Protection detection - Automatic Gain and Clamping control Input signal level Video Input ModeComposite Video signal 1.0Vpp S-Video Input ModeY+Synchro 1.0Vpp C burst level 0.286Vpp Component Input ModeY+Synchro 1.0Vpp Pr Pb RGB/HV/YPrPb Input Image 7-22 RGB/HV Input module 56R5976468 CINE VERSUM SYSTEM 03112003