    Have a look at the manual ATT DEFINITY Communications System Generic 3 For Single-Carrier Cabinets Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 164 ATT manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Test the System
    8-6Issue 1  September 1995  
    Screen 8-5. Example System Configuration Screen — Page 2
                                                                     Page   2
                                   SYSTEM CONFIGURATION
     Board                                                  Assigned Ports
     Number   Board Type              Code     Vintage    u=unassigned t=tti
     01C02    DIGITAL LINE             TN754B  000001     u  u  u  u  u  u  u  u
     01C04    CO TRUNK                 TN747B  000012     u  u  u  u  u  u  u  u
     01C05    E&M TIE TRUNK            TN437B  000001     u  u  u  u
     01C06    DS1 INTERFACE            TN464D  000002     u  u  u  u  u  u  u  u
                                                          u  u  u  u  u  u  u  u
                                                          u  u  u  u  u  u  u  u
                                                          u  u  u  u  u  u  u  u
     01C08    DS1 INTERFACE            TN464D  000002     u  u  u  u  u  u  u  u
                                                          u  u  u  u  u  u  u  u
                                                          u  u  u  u  u  u  u  u
                                                          u  u  u  u  u  u  u  u
     01C11    E&M TIE TRUNK            TN458   000005     u  u  u  u
     01C12    CO TRUNK                 TN438B  000001     u  u  u  u  u  u  u  u
     01C13    CO TRUNK                 TN447   000003     u  u  u  u  u  u  u  u
                     press CANCEL to quit --  press NEXT PAGE to continue 
    						
    							Check Circuit Pack Configuration
    Issue 1  September 1995 
    8-7
    Screen 8-6. Example System Configuration Screen — Page 3
     list configuration all                                              Page   3
                                   SYSTEM CONFIGURATION
     Board                                                  Assigned Ports
     Number   Board Type              Code     Vintage    u=unassigned t=tti
     01C15    DS1 INTERFACE            TN767   000017     u  u  u  u  u  u  u  u
                                                          u  u  u  u  u  u  u  u
                                                          u  u  u  u  u  u  u  u
     01C17    CALL CLASSIFIER          TN744   000007     01 02 03 04 05 06 07 08
     01C19    MAINTENANCE/TEST         TN771D  000006     u  02 03 u
     01C20    AUXILIARY TRUNK          TN763D  000005     u  u  u  u
     02A01    EXPANSION INTRFC         TN570B  000001
     02A02    TONE DETECTOR            TN748C  000005     01 02 03    05 06 07
     02A03    DIGITAL LINE             TN754   000010     u  u  u  u  u  u  u  u
     02A04    ANALOG LINE              TN467   000003     u  u  u  u  u  u  u  u
     02A05    TIE TRUNK                TN439   000004     u  u  u  u
     02A10    BRI LINE                 TN556   000009     u  u  u  u  u  u  u  u
                                                          u  u  u  u  u  u  u  u
                                                          u  u  u  u  u  u  u  u
                     press CANCEL to quit --  press NEXT PAGE to continue 
    						
    							Test the System
    8-8Issue 1  September 1995  
    Screen 8-7. Example System Configuration Screen — Page 4
     configuration all                                                            Page   4
                                   SYSTEM CONFIGURATION
     Board                                                  Assigned Ports
     Number   Board Type              Code     Vintage    u=unassigned t=tti
     02B01    TONE/CLOCK               TN780   000005
     02B02    EXPANSION INTRFC         TN570   000009
     02B04    ANALOG LINE             TN2135   000003     u  u  u  u  u  u  u  u
                                                          u  u  u  u  u  u  u  u
     02B06    DIGITAL LINE            TN2181   000001     u  u  u  u  u  u  u  u
                                                          u  u  u  u  u  u  u  u
     01A      DUPLICATION INTRFC       TN772   000012
     01A      PROCESSOR                TN786B  000004
     01A      MEMORY EXPANSION          CPP1   000005
     01A      NETWORK CONTROL          TN777B  000018     u  u  u  u
     01A      TONE/CLOCK              TN2182   000002     01 02 03 04 05 06 07 08
     01B      DUPLICATION INTRFC       TN772   000013
     01B      PROCESSOR                TN786B  000004
     01B      MEMORY EXPANSION          CPP1   000005
                     press CANCEL to quit --  press NEXT PAGE to continue 
    						
    							Test Time Division Multiplexor (TDM) Bus in Processor 
    Port Network (PPN)
    Issue 1  September 1995 
    8-9
    Screen 8-8. Example System Configuration Screen — Page 5 
    Test Time Division Multiplexor (TDM)
    Bus in Processor Port Network (PPN)
    1. Verify the screen displays:
    command:
    2. Type test tdm port-network 1 and press 
    ENTE R.
    3. Verify the screen displays the results of this test as shown in the example 
    on the following page.
    list configuration all                                                                         SPE B
                                   SYSTEM CONFIGURATION
     Board                                                  Assigned Ports
     Number   Board Type              Code     Vintage    u=unassigned t=tti
     01B      NETWORK CONTROL          TN777B  000018     u  u  u  u
     01B      TONE/CLOCK               TN2182  000002     01 02 03 04 05 06 07 08
     02A      MAINTENANCE              TN775B  000001
     02A      TONE/CLOCK               TN780   000005
     Command successfully completed 
    						
    							Test the System
    8-10Issue 1  September 1995  
    Screen 8-9. Example Test Results for Time Division Multiplexing (TDM) Port Network 1
    4. If the result is FAIL for any test, check the connectors of the Time 
    Division Multiplexing (TDM) bus cables in Processor Port Network (PPN) 1. 
    Test Tone-Clock Boards
    Testing the Tone-Clock board  also detects problems with the Time Division 
    Multiplexing (TDM) bus cables.
    1. Verify the screen displays:
    command:
    2. Type test tone-clock 1a and press 
    ENTE R.
    3. Verify the screen displays test results similar to the examp le shown on the 
    following p a ge:
    test tdm port-network 1                                                                        SPE B
                                      TEST RESULTS
       Port      Maintenance Name  Alt. Name Test No. Result            Error Code
       PN 01A    TDM-BUS                     294      PASS
       PN 01A    TDM-BUS                     296      PASS
       PN 01A    TDM-BUS                     297      ABORT             1005
       PN 01B    TDM-BUS                     294      PASS
       PN 01B    TDM-BUS                     296      ABORT             1005
       PN 01B    TDM-BUS                     297      PASS
     Command successfully completed
     Command: 
    						
    							Test Switch Processing Element (SPE)  Duplication 
    Memory Shadowing Link
    Issue 1  September 1995 
    8-11
      
    Screen 8-10. Example Test Results for Tone-Clock 1A
    Test Switch Processing Element (SPE)
    Duplication Memory Shadowing Link
    For High and Critical Reliability systems, test the Switch Processing Element 
    (SPE )  d u p lication; memory shadowing link. 
    1. Verify the screen displays:
    command:
    2. Type test shadow-link and press 
    ENT ER.
    3. Verify the screen displays test results similar to the examp le shown on the 
    following p a ge:
    test tone-clock 1a                                                         SPE A
                                      TEST RESULTS
       Port      Maintenance Name  Alt. Name Test No. Result            Error Code
       01A       TONE-BD                     46       PASS
       01A       TONE-BD                     52       PASS
       01AXX01   ETR-PT                      42       PASS
       01AXX01   ETR-PT                      43       PASS
       01AXX02   ETR-PT                      42       PASS
       01AXX02   ETR-PT                      43       PASS
       01AXX03   ETR-PT                      42       PASS
       01AXX03   ETR-PT                      43       PASS
       01AXX04   ETR-PT                      42       PASS
       01AXX04   ETR-PT                      43       PASS
       01AXX05   ETR-PT                      42       PASS
       01AXX05   ETR-PT                      43       PASS
       01AXX06   ETR-PT                      42       PASS
       01AXX06   ETR-PT                      43       PASS
     Command successfully completed
     Command: 
    						
    							Test the System
    8-12Issue 1  September 1995  
    Screen 8-11. Example Test Results for Switch Processing Element Duplication Memory 
    Shadowing  Link
    4. If result is FAIL for any test, check the Inter-Cabinet Cables (ICC) in 
    the Processor  Port  Network (PPN).
    Test Duplicated Switch Processing
    Element (SPE) Interchange
    For High and Critical Reliability systems, chec k the Switch Processing Element 
    (SPE )  i n t e rchange.
    1. Verify the screen displays:
    command:
    2. Type status system all-cabinets and press 
    ENT ER.
    3. Verify the screen displays test results similar to the examp le shown on the 
    following p a ge:
                                      TEST RESULTS
       Port      Maintenance Name  Alt. Name Test No. Result            Error Code
                 SHDW-LNK                    318      PASS
     Command successfully completed
      
    						
    							Test Duplicated Switch  Processing Element (SPE) 
    Interchange
    Issue 1  September 1995 
    8-13
    Screen 8-12. Example System Status Report for All Cabinets
    4. Note the MODE of SPE 1A and 1B.
    5. Type refresh spe and press 
    ENT ER.
    Command successfully completed should be displayed. 
    6. Type reset system interchange and press 
    ENT ER.
    This causes the terminal to log off.
    7. Log in as craft again. See Chapter 7, Activate the System for more 
    information.  Rememb er to use the new password established for craft.
    8. Type status system cabinets-all and press 
    ENT ER.
    9. A screen similar to the following should be displayed:
     
     status system all-cabinets                                                 SPE A
                                SYSTEM STATUS CABINET 1
                                SELECT  SPE ALARMS    TONE/  SERVICE SYSTEM  SYSTEM
     SPE  MODE                  SWITCH  MAJOR MINOR   CLOCK  STATE   CLOCK   TONE
     1A   active                 auto     1    0       1A     in     standby standby
     1B   maint/init             auto     1    0       1B     in     active  active
         SERVICE   CONTROL  DEDICATED         SERVICE  BUS ALARMS    BUS   OPEN BUS
     TDM  STATE    CHANNEL    TONES      PKT   STATE  MAJOR MINOR   FAULTS  LEADS
     1A    in         y          n       1
     1B    in         n          y
     EMERGENCY     SELECT                    SERVICE              CABINET
     TRANSFER      SWITCH      EXP-LINK      STATE     MODE       TYPE
     1A            auto-on     01A01-02A01    in       standby    MCC
     1B            auto-on     01B01-02B02    in       active
                                    -
                                    -
     Command successfully completed
     Command: 
    						
    							Test the System
    8-14Issue 1  September 1995  
    Screen 8-13. Example System Status Report for All Cabinets after Reset
    10. Note the MODE for SPE 1A and 1B should have changed from that noted 
    in Step 4.
    Test Expansion Interface Boards
    Check each expansion interface board in the system.
    1. Verify the screen displays:
    command:
    2. Type test board xxx where xxx is the c a binet, carrier, and slot (see note 
    on page 8-1) for an expansion interface board in the system, and press 
    ENT ER.
    NOTE:
    Labels on the port network and carrier containing the board and the 
    label  on the strip under the b oard contain this information.  
    3. Verify the screen disp lays test results similar to the example shown below:  
    This example is for board  2a01.
     - status system all-cabinets                                                 SPE B
                                SYSTEM STATUS CABINET 1
                                SELECT  SPE ALARMS    TONE/  SERVICE SYSTEM  SYSTEM
     SPE  MODE                  SWITCH  MAJOR MINOR   CLOCK  STATE   CLOCK   TONE
     1A   standby                auto     1    0       1A     in     standby standby
     1B   active                 auto     1    0       1B     in     active  active
         SERVICE   CONTROL  DEDICATED         SERVICE  BUS ALARMS    BUS   OPEN BUS
     TDM  STATE    CHANNEL    TONES      PKT   STATE  MAJOR MINOR   FAULTS  LEADS
     1A    in         y          n       1
     1B    in         n          y
     EMERGENCY     SELECT                    SERVICE              CABINET
     TRANSFER      SWITCH      EXP-LINK      STATE     MODE       TYPE
     1A            unavail     01A01-02A01    in       standby    MCC
     1B            auto-on     01B01-02B02    in       active
                                    - 
    						
    							Test Time Division Multi plexer (TDM) for each 
    Expansion Port Network (EPN)
    Issue 1  September 1995 
    8-15
    Screen 8-14. Example Test Results for Expansion Interface Board 2A01
    If any result is FAIL, chec k the connections for the associated fiber optic 
    link.
    4. Repeat Steps 2 and 3 for each expansion interface board in the system. 
    Test Time Division Multiplexer (TDM)
    for each Expansion Port Network 
    (EPN)
    Check each Time Division Multiplexer (TDM) for each Expansion Port Network 
    (EPN ) in the system.
    1. Verify the screen displays:
    command:
    2. Type test tdm port-network 2 and press 
    ENTE R.
    3. Verify a test results screen similar to the one below is disp layed:
                                    TEST RESULTS
      Port      Maintenance Name  Alt. Name Test No. Result            Error Code
      02A01     EXP-INTF                    237      PASS
      02A01     EXP-INTF                    238      PASS
      02A01     EXP-INTF                    240      PASS
      02A01     EXP-INTF                    241      PASS
      02A01     EXP-INTF                    244      PASS
      02A01     EXP-INTF                    316      PASS 
    						