Have a look at the manual ATT DEFINITY Communications System Generic 3 For Single-Carrier Cabinets Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 164 ATT manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Country-Sp e cific Hard ware Issue 1 Septemb er 1995 D-13 *PPM means Periodic Pulse Metering. AnnouncementTN75 0C TN750BTN75 0 Auxiliary TrunkTN76 3D TN763C Analog Direct Inward Dialed Trunk (DID) Not Applicable Analog Central Office (CO) Trunk (no PPM *)TN74 7B Analog Central Office (CO) Trunk (w/PPM *)TN46 5C TN465B 4 Wire T ie Trun k TN76 0D 2 Wire Tie Trunk Digital Central Office (CO)/Direct Inward Dialed (DID) TrunkTN46 4F Digital Tie Trun k TN46 4F TN464E TN46 4D TN464 C Digital Integrated Services Digital Network (ISDN) Central Office (CO) TrunkTN46 4F 8 port Analog LineTN74 2 16 port Analog LineTN74 6B 4 Wire Digital LineTN75 4B 2 Wire Digital Line Data LineTN72 6B Table D-14. Netherlands Netherlands Tone Detector TN744C TN2182TN42 0C Tone-Clock TN2182 TN780 Call Classifier TN744C TN2182TN74 4B R2MFC Circuit Not Ap plicable Speech Synthesizer TN457 Announcement TN750C TN750B Auxiliary Trunk TN763D Analog Direct Inward Dialed (DID) Trunk TN2146 Analog Central Office (CO) Trunk (no PPM *) TN2147C Analog Central Office (CO) Trunk (w/PPM *) Not Ap plicable 4 Wire Tie Trunk TN760Dv11 2 Wire Tie Trunk Table D-13. Mexico Mexico
Country Differences D-14Issue 1 September 1995 *PPM means Periodic Pulse Metering. Digital Central Office (CO)/Direct Inward Dialed (DID) TrunkTN 464F TN4 64E TN46 4D Digital Tie Trunk TN464F TN4 64E TN46 4D Digital Integrated Services Digital Network (ISDN) Central Office (CO) TrunkTN 464F TN4 64E TN46 4D 8 port Analog Line 16 port Analog Line TN2183 TN2144 4 Wire Digital Line TN754B 2 Wire Digital Line TN2136 Data Line TN726B Table D-15. Poland and Russia Poland Russia Tone DetectorTN744C TN2182 TN748D TN748C TN744C TN420C Tone-Clock TN2182 TN780 TN756 TN2182TN78 0 Call ClassifierTN74 4C TN2 182 TN744B R2MFC CircuitTN74 4C TN2 182 TN744B TN744CTN21 82 TN744Bv2 Speech SynthesizerTN72 5B TN 457 AnnouncementTN75 0C TN7 50B TN750CTN75 0B Auxiliary TrunkTN76 3D TN763D Analog Direct Inward Dialed (DID) TrunkTN75 3 TN753v17TN21 99 Analog Central Office (CO) Trunk (no PPM *)TN74 7B TN747Bv12TN21 99 Analog Central Office (CO) Trunk (w/PPM * )TN465CTN46 5B TN4 65 4 Wire T ie Trun k TN76 0D TN760Dv11 2 Wire Tie Trunk Digital Central Office (CO)/Direct Inward Dialed (DID) TrunkTN 464F Digital Tie Trunk TN464F TN464E TN464D TN464F Digital Integrated Services Digital Network (ISDN) Central Office (CO) TrunkNot ApplicableNot Ap plicable 8 port Analog LineTN74 2 16 port Analog LineTN74 6B TN746B Table D-14. Netherlands Netherlands
Country-Sp e cific Hard ware Issue 1 Septemb er 1995 D-15 *PPM means Periodic Pulse Metering. *PPM means Periodic Pulse Metering. 4 Wire Digital LineTN75 4B TN754B 2 Wire Digital LineTN21 81 TN2 136 TN2181TN21 36 Data LineTN72 6B TN726B Table D-16. Saudi Arabia Saudi Arabia Tone Detector TN744CTN2182 TN748D Tone-Clock TN2182 TN780 TN756 Call Classifier TN744C TN2182TN744 B R2MFC Circuit TN744CTN2182 TN744B Speech Synthesizer TN725B Announcement TN750CTN750B Auxiliary Trunk TN763DTN763C Analog Direct Inward Dialed (DID) Trunk TN753 Analog Central Office (CO) Trunk (no PPM *)TN7 47B Analog Central Office (CO) Trunk (w/PPM *) 4 Wire Tie Trunk TN760D 2 Wire Tie Trunk Digital Central Office (CO)/Direct Inward Dialed (DID) TrunkTN4 64F Digital Tie Trun k TN4 64F TN464E TN464 D TN4 64C TN464B Digital Integrated Services Digital Network (ISDN) Central Office (CO) TrunkTN4 64F 8 port Analog Line TN742 16 port Analog Line TN746B 4 Wire Digital Line TN754B 2 Wire Digital Line TN2181 Data Line TN726B Table D-15. Poland and Russia Poland Russia
Country Differences D-16Issue 1 September 1995 Table D-17. Singapore * PPM means Periodic Pulse Metering. Singapore Tone Detector TN744C TN2182 TN748D Tone-Clock TN2182 TN780 TN756 Call ClassifierTN744C TN2182 TN744B R2MFC Circuit TN744C TN2182 TN744B Speech SynthesizerTN725B Announcement TN750C TN750B TN750 Auxiliary Trunk TN763D TN763C Analog Direct Inward Dialed (DID) Trunk TN753 Analog Central Office (CO) Trunk (no PPM *)TN747B Analog Central Office (CO) Tru nk (w/PPM *) 4 Wire Tie TrunkTN760D 2 Wire Tie Trunk Digital Central Office (CO)/Direct Inward Dialed (DID) TrunkTN464F Digital Tie TrunkTN464F TN464E TN464D TN464C Digital Integrated Services Digital Network (ISDN) Central Office (CO) TrunkTN464F TN464E TN464D TN464C 8 port Analog Line TN742 16 port Analog Line TN746B 4 Wire Digital LineTN754B 2 Wire Digital Line Data LineTN726B Table D-18. Spain and Taiwan Spain Taiwan Tone DetectorTN74 4C TN218 2 TN420CTN744 C TN218 2 TN748 D Tone-Cloc kTN21 82 TN780 TN218 2 TN780 TN756 Call ClassifierTN74 4C TN218 2 TN744B R2MFC CircuitTN74 4C TN218 2 TN744Bv2 Not Applicable
Country-Sp e cific Hard ware Issue 1 Septemb er 1995 D-17 *PPM means Periodic Pulse Metering. Speech SynthesizerTN45 7 TN725 B AnnouncementTN75 0C TN750 B TN750 C TN750 B Auxiliary TrunkTN76 3D TN763 D TN763 C Analog Direct Inward Dialed (DID) TrunkNot ApplicableTN753 Analog Central Office (CO) Trunk (no PPM *)TN21 47C TN747 B Analog Central Office (CO) Trunk (w/PPM *)TN46 5C 4 Wire Ti e Trunk Not ApplicableTN760 D 2 Wire Ti e Trunk Not Applicable Digital Central Office (CO)/Direct Inward Dialed (DID) TrunkTN46 4F TN464 E Digital Tie TrunkTN46 4F TN464 F TN464 E TN464 D TN46 4C TN7 67 Digital Integrated Services Digital Network (ISDN) Central Office (CO) TrunkTN46 4F TN464 ENot Applicable 8 port Analog LineTN742 16 port Analog LineTN21 83 TN218 0 TN746 B 4 Wire Digital LineTN75 4B TN754 B 2 Wire Digital LineTN21 81 TN218 1 Da ta Li ne TN72 6B TN726 B Table D-18. Spain and Taiwan Spain Taiwan
Country Differences D-18Issue 1 September 1995 *PPM means Periodic Pulse Metering. Table D-19. United Kingdom United Kingdom Tone DetectorTN74 4C TN2182TN420 C TN42 0B Tone-Clock TN2182 TN780TN419 B Call ClassifierTN74 4C TN2182TN744 B R2MFC Circuit Not Applicable Speech SynthesizerTN45 7 AnnouncementTN75 0C TN750B Auxiliary TrunkTN76 3D TN417 Analog Direct Inward Dialed (DID) TrunkTN45 9B TN459 Analog Central Office (CO) Trunk (no PPM *)TN21 47C TN2147 Analog Central Office (CO) Trunk (w/PPM *)TN44 7 4 Wire T ie Trun k TN45 8 2 Wire Tie Trunk Digital Central Office (CO)/Direct Inward Dialed (DID) TrunkTN46 4F TN464E TN464 D Digital Tie Trun k TN46 4F TN464E TN464 D TN46 4C Digital Integrated Services Digital Network (ISDN) Central Office (CO) TrunkTN46 4F TN464E TN464 D 8 port Analog LineTN46 7 16 port Analog LineTN21 83 TN468BTN468 4 Wire Digital LineTN75 4B TN413 2 Wire Digital LineTN21 81 Data LineTN72 6B
Country-Sp e cific Hard ware Issue 1 Septemb er 1995 D-19 Table D-20. Venezuela * PPM means Periodic Pulse Metering. Venezuela Tone DetectorTN744C TN2182 TN748D Tone-Clock TN2182 TN780 TN756 Call Classifier TN744C TN2182 TN744B R2MFC Circuit TN744C TN2182 TN744B Speech SynthesizerTN725B AnnouncementTN750C TN750B TN750 Auxiliary TrunkTN763D TN763C Analog Direct Inward Dialed (DID) TrunkTN753 Analog Central Office (CO) Trunk (no PPM *) TN747B Analog Central Office (CO) Trunk (w/PPM *) TN465C TN465B 4 Wire Tie Trunk TN760D 2 Wire Tie Trunk TN439 Digital Central Office (CO)/Direct Inward Dialed (DID) TrunkNot Applicable Digital Tie TrunkTN464F TN464E TN464D TN464C Digital Integrated Services Digital Network (ISDN) Central Office (CO) TrunkNot Applicable 8 port Analog LineTN742 16 port Analog Line TN746B 4 Wire Digital LineTN754B TN413 2 Wire Digital LineTN2181 Data LineTN726B
September 1995 Issue 1 E-1 E Installing the 9400-Series Telephones Installing the 9400-Series Telephones The following figures provide the basic information to install the 9400-series telephones. !CAUTION: When this product is located in a separate building from the DEFI NIT Y Communications System, a line current protector MUST be installed at the entry/exit points of all buildings through which the line passes. However, there is a difference between 4-wire and 2-wire installations. The following are the ONLY acceptable devices for use in a 4-wire installation (note that two protectors are needed at each installation point): nAT&T 4-type protectors nITW L I NX™ LP-type protectors For 2-wire installations, the following is recommended (only one protector is needed at each installation point): nAT&T 4-type protectors nITW L I NX™ LP-type protectors However, if the above two protectors are not used, the following is acceptable in a 2-wire installation: nAT&T 3BIC (Carb on block) or AT&T 3BEW (gas tube) protectors
Installing the 9400-Series Telephones E-2Septemb er 1995 Issue 1 NOTE: The 3BIC and 3BEW protectors can be used only for 2-wire installations. They cannot be used for 4-wire installations. These telephones are not for residential use. They are for business systems applications only. Use in a residential environment could result in an electrical short circuit when the telephone wiring is set up to p rovide other applications, for example, for a p pliance control or p ower transformers. The AC power used in these applications may create a safety hazard by placing a direct short circ uit across the telephone wiring. Wiring Information The 9403 and the 9434 telephones work in both 2-wire and 4-wire configurations. The 9410 telephone works only in the 2-wire digital communications protocol (DCP) configuration. Wiring is also disc ussed in Chapter 9, Install and Wire Telephones and Other Equipment. Figure E-1 and Figure E-2 show an enlargement of a telephone 8-pin line jack in a 2-wire and a 4-wire configuration, resp ectively. Table E-1 b elow these figures describes the pins on this jack. Figure E-1 shows p ower requirements in a 2-wire installation. Switch connections must be on pair 1 (Pins 4 and 5). Figure E-1. A Telephone Line Jack in a 2-Wire Configuration Figure E-2 shows p ower requirements in a 4-wire installation. Switch connections must be on pair 2 (Pins 1 and 2) and pair 3 (Pins 3 and 6). 12345678
Wiring Information September 1995 Issue 1 E-3 Figure E-2. A Telephone Line Jack in a 4-Wire Configuration NOTE: Regardless of configuration, all wiring between the switch and the wall jack must consist of twisted-pairs. Use the sup plied line cord with the telephone, or use an AT&T a pproved equivalent. An 8-wire mo dular cord must be used for all 4-wire and 2-wire installations requiring auxiliary power for adjuncts such as a hands-free speaker/microphone. Table E-1. Pinouts on 8-Pin Line Jack Modular Wall Jack Wiring Pin Pair Color Description 1 2 W-O 4-Wire Output 2 2 O-W 4-Wire Output 3 3 W-G 4-Wire In put 4 1 BL-W 2-Wire (Tip ) 5 1 W-BL 2-Wire (Ring ) 6 3 G-W 4-Wire In put 7 4 W-BR Adjunct Power -48V 8 4 BR-W Adjunct Power Common 123 456 78