    Have a look at the manual ATT DEFINITY Communications System Generic 3 For Single-Carrier Cabinets Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 164 ATT manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Country-Sp e cific Hard ware
    Issue 1  Septemb er 1995 
    D-13
    *PPM means Periodic Pulse Metering.
    AnnouncementTN75 0C TN750BTN75 0
    Auxiliary TrunkTN76 3D TN763C
    Analog Direct Inward Dialed Trunk (DID) Not 
    Applicable
    Analog Central Office (CO) Trunk (no PPM *)TN74 7B
    Analog Central Office (CO) Trunk (w/PPM *)TN46 5C TN465B
    4 Wire T ie Trun k TN76 0D
    2 Wire Tie Trunk
    Digital Central Office (CO)/Direct Inward 
    Dialed (DID) TrunkTN46 4F
    Digital Tie Trun k TN46 4F TN464E TN46 4D TN464 C
    Digital Integrated Services Digital Network 
    (ISDN) Central Office (CO) TrunkTN46 4F
    8 port Analog LineTN74 2
    16 port Analog LineTN74 6B
    4 Wire Digital LineTN75 4B
    2 Wire Digital Line
    Data LineTN72 6B
    Table D-14. Netherlands
    Netherlands
    Tone Detector TN744C TN2182TN42 0C
    Tone-Clock TN2182 TN780
    Call Classifier TN744C TN2182TN74 4B
    R2MFC Circuit Not 
    Ap plicable
    Speech Synthesizer TN457
    Announcement TN750C TN750B
    Auxiliary Trunk TN763D
    Analog Direct Inward Dialed (DID) Trunk TN2146
    Analog Central Office (CO) Trunk (no PPM *) TN2147C
    Analog Central Office (CO) Trunk (w/PPM *) Not 
    Ap plicable
    4 Wire Tie Trunk TN760Dv11
    2 Wire Tie Trunk
    Table D-13. Mexico
    Mexico 
    						
    							Country Differences
    D-14Issue 1  September 1995  
    *PPM means Periodic Pulse Metering.
    Digital Central Office (CO)/Direct Inward Dialed 
    (DID) TrunkTN 464F TN4 64E TN46 4D
    Digital Tie Trunk TN464F TN4 64E TN46 4D
    Digital Integrated Services Digital Network (ISDN) 
    Central Office (CO) TrunkTN 464F TN4 64E TN46 4D
    8 port Analog Line
    16 port Analog Line TN2183 TN2144
    4 Wire Digital Line TN754B
    2 Wire Digital Line TN2136
    Data Line TN726B
    Table D-15. Poland and Russia
    Poland Russia
    Tone DetectorTN744C TN2182 TN748D TN748C TN744C TN420C
    Tone-Clock TN2182 TN780 TN756 TN2182TN78 0
    Call ClassifierTN74 4C TN2 182 TN744B
    R2MFC CircuitTN74 4C TN2 182 TN744B TN744CTN21 82 TN744Bv2
    Speech SynthesizerTN72 5B TN 457
    AnnouncementTN75 0C TN7 50B TN750CTN75 0B
    Auxiliary TrunkTN76 3D TN763D
    Analog Direct Inward 
    Dialed (DID) TrunkTN75 3 TN753v17TN21 99
    Analog Central Office (CO) 
    Trunk (no PPM *)TN74 7B TN747Bv12TN21 99
    Analog Central Office (CO) 
    Trunk (w/PPM * )TN465CTN46 5B TN4 65
    4 Wire T ie Trun k TN76 0D TN760Dv11
    2 Wire Tie Trunk
    Digital Central Office 
    (CO)/Direct Inward Dialed 
    (DID) TrunkTN 464F
    Digital Tie Trunk TN464F TN464E TN464D TN464F
    Digital Integrated Services 
    Digital Network (ISDN) 
    Central Office (CO) TrunkNot 
    ApplicableNot 
    Ap plicable
    8 port Analog LineTN74 2
    16 port Analog LineTN74 6B TN746B
    Table D-14. Netherlands
    Netherlands 
    						
    							Country-Sp e cific Hard ware
    Issue 1  Septemb er 1995 
    D-15
    *PPM means Periodic Pulse Metering.
    *PPM means Periodic Pulse Metering.
    4 Wire Digital LineTN75 4B TN754B
    2 Wire Digital LineTN21 81 TN2 136 TN2181TN21 36
    Data LineTN72 6B TN726B
    Table D-16. Saudi Arabia
    Saudi Arabia
    Tone Detector TN744CTN2182 TN748D
    Tone-Clock TN2182 TN780 TN756
    Call Classifier TN744C TN2182TN744 B
    R2MFC Circuit TN744CTN2182 TN744B
    Speech Synthesizer TN725B
    Announcement TN750CTN750B
    Auxiliary Trunk TN763DTN763C
    Analog Direct Inward Dialed (DID) Trunk TN753
    Analog Central Office (CO) Trunk (no PPM 
    *)TN7 47B
    Analog Central Office (CO) Trunk (w/PPM *)
    4 Wire Tie Trunk TN760D
    2 Wire Tie Trunk
    Digital Central Office (CO)/Direct Inward 
    Dialed (DID) TrunkTN4 64F
    Digital Tie Trun k TN4 64F TN464E TN464 D TN4 64C TN464B
    Digital Integrated Services Digital Network 
    (ISDN) Central Office (CO) TrunkTN4 64F
    8 port Analog Line TN742
    16 port Analog Line TN746B
    4 Wire Digital Line TN754B
    2 Wire Digital Line TN2181
    Data Line TN726B
    Table D-15. Poland and Russia
    Poland Russia 
    						
    							Country Differences
    D-16Issue 1  September 1995  
    Table D-17. Singapore
    *
    PPM means Periodic Pulse Metering.
    Singapore
    Tone Detector TN744C TN2182 TN748D
    Tone-Clock TN2182 TN780 TN756
    Call ClassifierTN744C TN2182 TN744B
    R2MFC Circuit TN744C TN2182 TN744B
    Speech SynthesizerTN725B
    Announcement TN750C TN750B TN750
    Auxiliary Trunk TN763D TN763C
    Analog Direct Inward Dialed (DID) Trunk TN753
    Analog Central Office (CO) Trunk (no 
    PPM *)TN747B
    Analog Central Office (CO) Tru nk 
    (w/PPM *)
    4 Wire Tie TrunkTN760D
    2 Wire Tie Trunk
    Digital Central Office (CO)/Direct Inward 
    Dialed (DID) TrunkTN464F
    Digital Tie TrunkTN464F TN464E TN464D TN464C
    Digital Integrated Services Digital Network 
    (ISDN) Central Office (CO) TrunkTN464F TN464E TN464D TN464C
    8 port Analog Line TN742
    16 port Analog Line TN746B
    4 Wire Digital LineTN754B
    2 Wire Digital Line
    Data LineTN726B
    Table D-18. Spain and Taiwan
    Spain Taiwan
    Tone DetectorTN74 4C TN218 2 TN420CTN744 C TN218 2 TN748 D
    Tone-Cloc kTN21 82 TN780 TN218 2 TN780 TN756
    Call ClassifierTN74 4C TN218 2 TN744B
    R2MFC CircuitTN74 4C TN218 2 TN744Bv2 Not 
    Applicable 
    						
    							Country-Sp e cific Hard ware
    Issue 1  Septemb er 1995 
    D-17
    *PPM means Periodic Pulse Metering.
    Speech 
    SynthesizerTN45 7 TN725 B
    AnnouncementTN75 0C TN750 B TN750 C TN750 B
    Auxiliary TrunkTN76 3D TN763 D TN763 C
    Analog Direct 
    Inward Dialed 
    (DID) TrunkNot 
    ApplicableTN753
    Analog Central 
    Office (CO) 
    Trunk (no PPM *)TN21 47C TN747 B
    Analog Central 
    Office (CO) 
    Trunk (w/PPM *)TN46 5C
    4 Wire Ti e Trunk Not 
    ApplicableTN760 D
    2 Wire Ti e Trunk Not 
    Applicable
    Digital Central 
    Office 
    (CO)/Direct 
    Inward Dialed 
    (DID) TrunkTN46 4F TN464 E
    Digital Tie TrunkTN46 4F TN464 F TN464 E TN464 D TN46 4C TN7 67
    Digital 
    Integrated 
    Services Digital 
    Network (ISDN) 
    Central Office 
    (CO) TrunkTN46 4F TN464 ENot 
    Applicable
    8 port Analog 
    LineTN742
    16 port Analog 
    LineTN21 83 TN218 0 TN746 B
    4 Wire Digital 
    LineTN75 4B TN754 B
    2 Wire Digital 
    LineTN21 81 TN218 1
    Da ta Li ne TN72 6B TN726 B
    Table D-18. Spain and Taiwan
    Spain Taiwan 
    						
    							Country Differences
    D-18Issue 1  September 1995  
    *PPM means Periodic Pulse Metering.
    Table D-19. United Kingdom
    United Kingdom
    Tone DetectorTN74 4C TN2182TN420 C TN42 0B
    Tone-Clock TN2182 TN780TN419 B
    Call ClassifierTN74 4C TN2182TN744 B
    R2MFC Circuit Not 
    Applicable
    Speech SynthesizerTN45 7
    AnnouncementTN75 0C TN750B
    Auxiliary TrunkTN76 3D TN417
    Analog Direct Inward Dialed (DID) TrunkTN45 9B TN459
    Analog Central Office (CO) Trunk (no PPM *)TN21 47C TN2147
    Analog Central Office (CO) Trunk (w/PPM *)TN44 7
    4 Wire T ie Trun k TN45 8
    2 Wire Tie Trunk
    Digital Central Office (CO)/Direct Inward Dialed 
    (DID) TrunkTN46 4F TN464E TN464 D
    Digital Tie Trun k TN46 4F TN464E TN464 D TN46 4C
    Digital Integrated Services Digital Network 
    (ISDN) Central Office (CO) TrunkTN46 4F TN464E TN464 D
    8 port Analog LineTN46 7
    16 port Analog LineTN21 83 TN468BTN468
    4 Wire Digital LineTN75 4B TN413
    2 Wire Digital LineTN21 81
    Data LineTN72 6B 
    						
    							Country-Sp e cific Hard ware
    Issue 1  Septemb er 1995 
    D-19
    Table D-20. Venezuela
    *
    PPM means Periodic Pulse Metering.
    Venezuela
    Tone DetectorTN744C TN2182 TN748D
    Tone-Clock TN2182 TN780 TN756
    Call Classifier TN744C TN2182 TN744B
    R2MFC Circuit TN744C TN2182 TN744B
    Speech SynthesizerTN725B
    AnnouncementTN750C TN750B TN750
    Auxiliary TrunkTN763D TN763C
    Analog Direct Inward Dialed (DID) TrunkTN753
    Analog Central Office (CO) Trunk (no PPM *) TN747B
    Analog Central Office (CO) Trunk (w/PPM *) TN465C TN465B
    4 Wire Tie Trunk TN760D
    2 Wire Tie Trunk TN439
    Digital Central Office (CO)/Direct Inward 
    Dialed (DID) TrunkNot 
    Applicable
    Digital Tie TrunkTN464F TN464E TN464D TN464C
    Digital Integrated Services Digital Network 
    (ISDN) Central Office (CO) TrunkNot 
    Applicable
    8 port Analog LineTN742
    16 port Analog Line TN746B
    4 Wire Digital LineTN754B TN413
    2 Wire Digital LineTN2181
    Data LineTN726B 
    						
    							September 1995 Issue 1 E-1 
    E
    Installing the 9400-Series Telephones
    Installing the 9400-Series Telephones
    The following figures provide the basic information to install the 9400-series 
    telephones.
    !CAUTION:
    When this product is located in a separate building from the DEFI NIT Y 
    Communications System, a line current protector MUST be installed at the 
    entry/exit points of all buildings through which the line passes. However, 
    there is a difference between 4-wire and 2-wire installations.
    The following are the ONLY acceptable devices for use in a 4-wire installation 
    (note that two protectors are needed at each installation point):
    nAT&T 4-type protectors
    nITW  L I NX™ LP-type protectors
    For 2-wire installations, the following is recommended (only one protector is 
    needed at each installation point):
    nAT&T 4-type protectors
    nITW  L I NX™ LP-type protectors
    However, if the above two protectors are not used, the following is acceptable in 
    a 2-wire installation:
    nAT&T 3BIC (Carb on block) or AT&T 3BEW (gas tube) protectors 
    						
    							Installing the 9400-Series Telephones
    E-2Septemb er 1995 Issue 1  
    NOTE:
    The 3BIC and 3BEW protectors can be used only for 2-wire installations. 
    They
     cannot be used for 4-wire installations.
    These telephones are 
    not for residential use. They are for business systems 
    applications only. Use in a residential environment could result in an electrical 
    short circuit when the telephone wiring is set up to p rovide other applications, for 
    example, for a p pliance control or p ower transformers. The AC power used in 
    these applications may create a safety hazard by placing a direct short circ uit 
    across the telephone wiring.
    Wiring Information
    The 9403 and the 9434 telephones work in both 2-wire and 4-wire configurations. 
    The 9410 telephone works 
    only in the 2-wire digital communications protocol 
    (DCP) configuration. Wiring is also disc ussed in Chapter 9, Install and Wire 
    Telephones and Other Equipment.
    Figure E-1 and Figure E-2 show an enlargement of a telephone 8-pin line jack in 
    a 2-wire and a 4-wire configuration, resp ectively. Table E-1 b elow these figures 
    describes the pins on this jack.
    Figure E-1 shows p ower requirements in a 2-wire installation. Switch connections 
    must be on pair 1 (Pins 4 and 5).
    Figure E-1. A Telephone Line Jack in a 2-Wire Configuration
    Figure E-2 shows p ower requirements in a 4-wire installation. Switch connections 
    must be on pair 2 (Pins 1 and 2) and pair 3 (Pins 3 and 6).
    12345678 
    						
    							Wiring Information
    September 1995 Issue 1 
    E-3
    Figure E-2. A Telephone Line Jack in a 4-Wire Configuration
    NOTE:
    Regardless of configuration, all wiring between the switch and the wall jack 
    must consist of twisted-pairs. Use the sup plied line cord with the telephone, 
    or use an AT&T a pproved equivalent. An 8-wire mo dular cord 
    must be used 
    for all 4-wire and 2-wire installations requiring auxiliary power for adjuncts 
    such as a hands-free speaker/microphone.
    Table E-1. Pinouts on 8-Pin Line Jack
    Modular Wall Jack Wiring
    Pin Pair Color Description
    1 2 W-O 4-Wire Output
    2 2 O-W 4-Wire Output
    3 3 W-G 4-Wire In put
    4 1 BL-W 2-Wire (Tip )
    5 1 W-BL 2-Wire (Ring )
    6 3 G-W 4-Wire In put
    7 4 W-BR Adjunct Power -48V
    8 4 BR-W Adjunct Power Common