ADS XiLog+ System User Manual 45 Merge multiple days Choose this option to import data for several days, and then designate the start and e nd dates representing the date range for which to import the data usi ng the Start Date and End Date calendar controls. Note: The calendar controls only allow the selection of dates for which data is available. When multiple days are selected, the system will average the data for each time period for every day in the range. For example, to obtain the profile value for 2:00, the system will average the data recorded at 2: 00 for every day in the range. 3. Click on the Load Data button to import and display the data on a graph. Profile Alarms To edit the profile data, click on the Auto Fit button. PrimeWorks places a marker on the trace at each 15 -minute interval to allow modification of the value, if required. Profile graph If historical data is not available , click on the Reset button to set default values for each profile value so that each one can be set independently. To change a profile value, simply click on the graph marker and drag it to a new location on the graph. Use t he zoom & pan buttons to rescale the Y -axis for the data displayed. Select ing a profile value highlight s the value on the graph and displays the actual value in the Selected Value field . For greater accuracy, enter another value in this field. Disable a value, when necessary, by selecting the value and then c licking on the Disable Selected Profile checkbox. When a value is disable d, XiLog+ will not generate alarms during th e corresponding 15-minute period.
ADS XiLog+ System User Manual 46 Disabling a value on the graph Enable the alarms for this profile period again by deselecting the Disable Selected Profile checkbox. After e ntering the required profile , select the deadband and debounce delay (when necessary) . The d eadband around the profile can represent either a single value or a percentage. When it represents a percentage, the value entered for the deadband corresponds to the percentage of the profile value. The system will trigger a high alarm if the channel re ading remains above the profile value plus the deadband for the designated debounce delay period. Selecting the deadband For example, when applying a flow profile value of 0.114 mgd with a deadband of 0.023 mgd , the logger will generate a high alarm during this period for a reading above 0.137 mgd and a low alarm for a reading below 0.091 mgd. If the deadband were designated as 10% instead , the logger would gener ate a high alarm above 0.126 mgd and a low alarm below 0.103 mgd. Envelope Alarms In addition to the standard Profile alarms, XiLog+ can generate alarms based on a more complex Envelope alarm . Envelope alarms allow importing of profile data in the same way as standard profile alarms. However, clicking on the AutoFit button displays two rows of markers for editing (as required) on the graph instead of only a single row of markers .
ADS XiLog+ System User Manual 47 Using the Autofit option for Envelope alarms This provides the flexibility to change the values used to generate the high and low alarms for each period independently . Select, change, move, and disable s pecific values using the same methods applied for standard profiles .
ADS XiLog+ System User Manual 48 Remote Data Reporting Remote Data Reporting window This window includes the parameters for setting up remote delivery of data fro m the XiLog+ to the designated host system (s ). Message Type This drop-down list contains the options for selecting the delivery method ( SMS or FTP using GPRS technology) through whi ch the XiLog+ will send data. Selecting SMS sends reports to as many as 3 host numbers (when applicable). Selecting FTP transfers data via FTP (File Transfer Protocol) to an FTP Server. This requires entering the details of the server. Use Automatic GSM Clock Correction Se lecti ng this checkbox automa tically adjusts the clock in the XiLog+ to the time in the GSM network. Using this option for FTP messaging requires identifying the specific server address (URL) at which the time sync script (PHP file) is available and designating the appropriate port. Enter this information in the Synchronization Script URL and Port fields.
ADS XiLog+ System User Manual 49 Ignore Daylight Savings Selecting this checkbox prevents the clock in the XiLog+ from compensating for daylight savings time. Host and Alarm Numbers When performing remote data reporting via SMS, the XiLog+ transmits the data to all the host numbers designated in the Contact Details section. A host number corresponds to a GSM modem connected to a computer. T he Primayer Data Manager utility running within Windows serves as the conduit through which the data is transferred from the GSM modem to the PrimeWorks software for viewing . Up to three host numbers may be entered in PrimeWorks , allowing data delivery to up to three different offi ces or locations. U p to two additional alarm numbers also may be entered. Any SMS alarms generated by the logger will be sent to these numbers. The logger sends data only to the host number (s); however, it sends alarms to both the host and alarm numbers , when necessary . Note: To use the Primayer XMS system for remote data delivery over the Internet, select the Us e XMS H ost checkbox and then select t he appropriate network from the corresponding drop- down list. Choosing this option does not require enteri ng any additional numbers or contact information. All distribution of data occurs within the XMS system. FTP Server Address This field displays the address of the FTP server to which the logger should transmit the data. When using the Primayer XMS delivery system , enter www.waterlogger.co.uk. When using another FTP server, enter the address without an FTP prefix . FTP Username This field displays the username for logging onto the FTP server. Enter the appropri ate username for the user . Note: When using the Primayer XMS system , defer to ADS Client Services to obtain the proper log in details.
ADS XiLog+ System User Manual 50 FTP Password This field represents the password for logging onto the FTP server. Enter the appropriate password for th e user . Test Login Details Clicking on this button verifies the FTP server address, username, and password by attempting to call and log into the server. PrimeWorks will provide notification of success or failure. A failure may indicate the wrong server ad dress or login information. Combine Flow and Pressure When using a 2i or 3i version of the XiLog+ and sending data via SMS, the flow and pressure data can be included in a single SMS. For this to occur, set up the system to log pressure at a 15 -minute int erval and flow at a 15 -minute interval. Designating these criteria enables the Combine Flow and Pressure checkbox for selection. Selecting this checkbox sends a single SMS (instead of two) representing both channels each da y. Data Transmission Data Transmission sub- window This window contains the parameters for setting up the process the XiLog+ uses for transmitting logged data. Daily Data Transmission S electing the Transmit Daily checkbox programs the logger to send the data once every day at the same time. When using this option, enter the time to perform the daily transmission in the Start field.
ADS XiLog+ System User Manual 51 Data Transmission at Other Intervals Programming the logger to perform data transmission u sing a different regime requires selecting or setting several pa rameters: 1. Select the interval at which to send the data from the Transmission Frequency drop-down list. 2. Designate the period of time within which the logger should conduct data transmission in the S tart and E nd fields. Choosing a frequency of 12 or 24 hou rs only requires designating the time at which to perform transmission during the selected day(s) in the Start time field. 3. Select the checkboxes corresponding to the days on which to have the logger transmit data (based on the designated frequency and time range) from the options under A ctive Days. 4. Select the order in which to send the data from the Data Transmit Order drop- down list. Choosing Newest First ensures the logger sends the most current data first. For example, a logger could be pr ogrammed to transmit data every hour between 8 am and 6 pm Monday through Friday. Strategically managing the transmission times can maximize the life of the battery in the logger . To manage the costs associated with SMS transmission, the XiLog+ refrains from sending an SMS until the transmission will be somewhat full, regardless of the selected frequency. Each SMS can contain up to 96 values. For example, logging data at a 5 -min ute interval for an 8- hour period will produce enough data t o fill an SMS transmission. Therefore, logging at this interval, the XiLog+ would transmit data via SMS approximately every 8 hours, even if the logger is preconfigured to transmit data on an hourly basis. This c ontrols the costs associated with SMS tran smission and prevents the duplication of data. Transmitting data via FTP does not involve these restrictions. At each transmission interval, the XiLog + will send all new data by FTP. Optional Receive Frequency Window This window contains the parameters for enabling t he modem to receive data. These settings are independent of the settings on the main data transmission window.
ADS XiLog+ System User Manual 52 Optional Receive Frequency Window Standby Window This window exists for applications where the XiLog+ will provide constant power to the modem so that it is available to accommodate instant aneous requests for data. Standby Window
ADS XiLog+ System User Manual 53 C H A P T E R 4 Battery Replacement 1. Carefully unscrew the yellow cover of the XiLog+ counter -clockwise 1/8 of a turn and lift it off the housing. 2. Carefully lift out the antenna and circuit board from the housing . 3. Disconnect or unplug the battery from the board. 4. Remove the screws securing the battery holder to the housing.
ADS XiLog+ System User Manual 54 5. Remove the battery holder from the housing. 6. Remove the battery from the holder.